waste burner provider in china



  1. Burning rate: 250 Kg/hr.
  2. It should be able to Operate not Less than 10 hours/day
  3. This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
  4. Design Specification: Types A, B, C, D, and E of medical waste
  5. “PYROLYTIC” combustion, by controlling the gasification of waste.
  6. The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings.
  7. It should be able to reduce the volume of wastes by 98%.
  8. It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.

This burner with “PYROLYTIC” burning should have:

  1. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
  • The Temperatures of combustion:Minimum will be 850oC and max 1400oC
  • Post combustion: >1100o
  1. The Internal diameter of the Chimney: Ø 400mm² and its height: 8 Meter
  2. The Volume of the combustion chamber: Not Less Than 2.3 M³
  3. Burner operation should be Automatic On/Off
  4. Fuel : diesel, LPG, Natural Gas, Bio fuel
  5. The supplier must provide  necessary information for the best of  the installation

* Entirely limited door for the hand-operated loading of waste.The packing requirement to be Handbook, Set Lots,

  1. A combustion chamber of waste:

* A burner of lighting which the usage is limited to the ignition of waste.

* Make-up of the refractory;

* Burner of illumination of waste, with gas, conventional mono-bloc dispersing routing diving flame, lighting and safety of electronic ignition, permanent air flow, electromagnetic sluice entrance of standard and also isolating shutoff.

* A burner of burning of gases,

* A device of shot of air enabling a total recombustion of gases,

  • Refractory concrete :
    • . Thickness : ≥100 mm
    • . Nature: 42% of Al203
  • Insulate in fibrous panels :
    • . Thickness: ≥75 mm
  • Nature: Calcium silicate.

* A gadget of air inlet of air conditioning of waste gases,

* A sheath of emptying of the gases blistered.

  1. Load Method: Top Loading
  1. A chamber of post combustion of gases

* A burner of combustion of gases,

* A device of shot of air enabling a complete recombustion of gases,

* A gadget of air inlet of cooling of waste gases,

* A sheath of evacuation of the gases scorched.

* Carcass in solid sheet steel with support of connection.

* Composition of the refractory;

  • Refractory concrete :
    • Thickness : ≥180 mm
    • Nature: 65% of Al203
  • Insulate in fibrous panel :



Tiniest Heater 30kgs


Conventional 30kgs per hr

*** Secret room ( 200Liters)

*** 2nd chamber

*** Mix burning chamber

*** Stainless-steel smokeshaft( 1meter)

*** Italy made oil heater( 2sets)

*** Dry Scrubber

*** Weight 1.7 T( can reduce to 1.0 Lot)

Trick Spare Components( Standard for incinerator, and additionally cost contain presently):

*** 2 collections Italy Oil Heating system

*** 2sets Infection Level Probe

*** 1 developed Control Instance

*** 1 developed Air Follower

*** 1 established Diesel Oil Tank



HICLOVER – Medical Environmental 

*** 1 established Maintain Item


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-24


Small Scale Incinerator Medical Waste


Basic Info.

Model NO.:veterinary waste incineration
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. 

Nanjing Clover Medical Technology Co., Ltd..

Key Features:  * All versions with Dual combustion chamber. *based on sequence Stainless Steel chimney/stack, long life. *based on sequence * High temperature, long life of incinerator.  * Free or minimum installation onsite.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.  *based on order  New Design for pet animal cremation enterprise.  * One year warranty on incinerator and components in stock. 

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

The factory workshop local in liuhe Economic Development Zone, suburb of Nanjing and business division local in downtown region. Presently, incinerator line products marketplace insure former Soviet Union region, Africa states, Asia states and Middle East region.  From year 2010, we negotiated with upgraded technologies from Europe and America manufacturers and establish cooperation relationship in the territory of China marketplace. Regrettably, competition in different countries marketplace, nation discrimination and anxieties of intellectual property rights trigger failure finally. Currently we investment more attempt, capital and technology development in our own brand, we are to be among the largest incineration equipment on earth. We have trading branch company for expert export business support.

30 kgs clinical waste incinerators for covid19 waste


Q: what is kind of waste can use in this devices?

A: This equipment for clinical waste, pet dog animal, Municipal waste, real-time waste. Ban any kind of explosive and radiation product, fluid waste as well as gas waste.

Items/Model

TS30( PLC)

Shed Rate

Average 30 kg/hour

Feed Ability

Average 60kg per feeding

Control Mode

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

330L

Interior Measurements

75x75x60cm

Second Chamber

180L

Smoke Filter Chamber

Yes

Feed Setting

Handbook Feeding

Voltage

220V

Power

0.5 Kw

Oil Consumption (kg/hour)

Average 13.3

Gas Usage (N.G, m3n/Hour)

Typical 16

Gas Usage (L.P.G, m3n/Hour)

Ordinary 11.7

Temperature Screen

Four Digital Present

Temperature Protection

Yes

Oil Storage Tank

200L

Feed Door

55x50cm

Smokeshaft

5Meter

Smokeshaft Type

Stainless Steel

1st. Chamber Temperature Level

800 ℃–– 1000 ℃

2nd. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

3000kg

Exterior Dimensions

175x120x140cm


HICLOVER – Medical Environmental, WWW.HICLOVER.COM, Waste Incinerators, 
Medical Waste Incinerator,Pet Animal Cremation, Solid Waste Incinerators

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator(Containerized Mobile Incinerator)

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.



 

2020-07-06


Scientific waste burner 100kgs Style TS100


incinerator manufacturer,medical incinerator,small scale incinerator,oil fired incinerator

Items/Model

TS100

Shed Cost

Frequent 100 kg/hour

Feed Capacity

Standard 200 kg/feed

Control Mode

PLC

Combustion Chamber

1200L

Interior Measurements

120x100x100cm

Secondly Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Electricity

0.7 Kw

Oil Intake (kg/hour)

14– – 28

Gas Consumption (m3/hour)

10– – 32.2

Temperature Level Monitor

Yes

Temperature Level Degree Protection

Yes

Oil Container

200L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st.

Gross Weight

6000kg

External Dimensions

260x150x180cm

{
(adsbygoogle = window.adsbygoogle || []).push({});|}

2020-04-06

External Measurements

260x150x180cm



HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-06

(adsbygoogle = window.adsbygoogle || []).push({});


Incinerateur


Basic Info.

Export Markets:Global

Additional Info.

Trademark:clover
Origin:China
Production Capacity:1000 Sets Per Year

Product Description

Key Attributes:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to sequence * High temperature, long life of incinerator.  * Free or minimum installation on site.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton daily.  * PLC Control Plane. *according to order  * New Design for pet animal cremation enterprise.  * One year warranty on incinerator and components in stock. 

Nanjing Clover Medical Technology Co., Ltd. is a leading incinerator maker in China. We are local manufacturer and among the largest exporter of China. Burner chamber manufacturer, burner combustion, burner gas, burner gas combustion efficiency, burner for health, burner incinerator LPG, burner untuk incinerator, burners for clinical waste, You can find our incinerator product in the former Soviet Union region, Africa countries, Asia countries and Middle East region. Follow market requirements, we supply different design series and design details according to each order. Clover Medical consider that the very best alliance is trust. The relationship between customer and clover medical is not just seller and buyer, we hope to create achievement together.

Item Customer Request Example
Application Scope  
 
 
 
Hospital, Pet Crematory, Slaughter House, Laboratories, School, Community, etc. if for animal/pet, indicate animal size like: cat, dog, cattle, etc
What kind of waste?  
____, _____%
____, _____%
____, _____%
 
 
Medical waste, dead animal, Municipal Waste, etc(detail name) or nature percent
if for animal/pet, indicate animal size like: cat, dog, cattle, etc
Quantity Request    
01.02.03^…unit
 
Budget    
$US Dollar.
 
 
Operating Time    
The staff work Hours per day.
Our incinerator can work up to around 18 hours per day.
Realization Date of project In ___ year  
Waste Output Capacity per Day?  
 
1000kgs Per Day^
Request waste burn rate   Capacity: 100kgs Per hour^
Request waste feed capacity   Capacity: 100kgs per feed^
Whether Natural Gas Supply Local?   Yes or No.
Local Power   If 380V and 220V valid?
Product Installation Destination  
 
Country or City name
DestinationSeaport name?   To check sea freight charge.
 
Customer    
End-Customer, Agent, Government.
 
Method of contract   Tender or Negotiation
Date of Tender limit    
How did you know our company?    
Other request or information  
 
 
 

medical was incinerators Department of Wellness


university hospital waste administration group in a tertiary care health center,1250 beeded hsopital.

our regular waste developed from sources is 0.55 kg/bed/day =685kg/day

we need an incinerator of 150kg/hour filling up ability.

plz reply with, obtaining, installation, running along with care cost.incinerators, particularly, clinical was heaters

Needs of Heater

1. Need to possess prep function, Incineration, Scrubber activities to thaw waste completely in addition to likewise waste gas have to be non-polluted

2. Ash must be just 5 percent of the waste material

5.

our day-to-day waste created from all resources is 0.55 kg/bed/day =685kg/day

we need a burner of 150kg/hour filling up skill. The specification of the Heater is as listed below:

Requirements of Burner

1. Should have preparation, Incineration, Scrubber activities to thaw waste completely and additionally waste gas need to become non-polluted

2. 1 year service guarantee

10. ISO Licensed

11. Mobile Burner

12. Electric

(adsbygoogle = window.adsbygoogle || []).push({});|The specification of the Heater is as detailed below:


Price to Purchase a Medical Waste Incinerator


Basic Info.

Model NO.:cremation equipment for sale in china
Export Markets:Global

Product Description

Key Features:  * All models with Dual combustion room.  * Stainless Steel chimney/stack, long life. *based on sequence * High fever, long life of incinerator.  * Free or minimal installation onsite.  * High burn rate, from 10kgs to 500kgs per hourto 6ton per day.  *based on order  New Design for pet animal cremation enterprise.  * One year warranty on incinerator and parts in stock. 

Program Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Community & Sea Port &bull creature, cremation animale, cremation burner, cremation burners, cremation equipment, cremation equipment china, cremation equipment design, cremation equipment for sale, Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.