Incineration Heating device for burning patalogical


incineration Heating system for shedding patalogical (such as human cells or blood) as west

The weight of this west products is 700 kg each month and we also require an isolated heater

With no fume along with any kind of kind of damaging gas

. INCINERATOR REQUIREMENTS

# Recap Spec

1 Burning Capacity – – – – 400 kg/time and also need to not be much less than 300 kg/time. Maximum burning time require to be 6 times/day

2 Smokeshaft outside diameter – – – – 300 to 400 millimeter

3 Processor electricity – – – Need to not exceed 1.1 kw

4 Voltage – – – – 220V

5 Oil ingestion – – – Have to not transcend 14kg/h

6 Feeding door 1.1 measurement (mm) – – – – Not much less than 500mm 7 Incineration Temperature. (⁰ C) – – – – 800 or over 8 Exhaust

Carbon Monoxide – – – – Have to not exceed 100 mg/m3

SO2 – – Need to not exceed 400 mg/m3

HF – – – – (Hydrogen fluoride) Must not exceed 9.0 mg/m3

NO2 – – – – Must not go past 500 mg/m3

Smoke dirt – – – – Should not go past 100 mg/m3

9 Elevation of the Burner – – – – hardly any less than 10m over ground level

10 Manufacturer’s Option guarantee – – – – Not much less than 1 year

11 Electrical Connect – – – – From closest blood circulation box with 25mm2 electric cord and also all pertinent links and circuitry


An animal burner for the cremation of pets


We have a 70 mattress clinical center in namibia. There’s a potential of getting clients from many other regional physicians.
Can you please give me some information regarding these kind of incinerators (little variety ). It will surely be solitary utilization of every pet seperately.Initially we are getting ready to begin this Pilot Job with the National Medical center, to convince the Ministry Officials in addition to on its achievement to take this job to the Teaching Hospitals, Location and Base Hospitals from the Country.municipality demand 4 crematory apparatus for bodies. I want some information regarding cost, kine of electricity for detection, poisonous exhaust, The incinerator we are looking must be with the benefits of Cozy recycling system, usage of hot water, and so on.


The 3 burners for melting as well as incineration of medicines as well as harmful substances


Needs and specs for the practice of supply, installation, performance and ensure the 3 incinerators for burning and incineration of medications as well as also harmful substances for customizeds branch

Free 3 years warranty for incinerators from dispatch day. Additionally of free of charge additional components ensure letter must stand for a single decade from conclusion day of assurance.

4-copmany needs to dedicated shipping, procedure, and likewise installation within 60 days from the date of site tasks detection.
Offered time asap
The company should make all the maintenance work also adjustment of their control and security devices as well as also filterings system/ filters cleanse insulation.{
(adsbygoogle = window.adsbygoogle || []).push({});|}{
(adsbygoogle = window.adsbygoogle || []).push({});|}
1. Educating for experts as well as also vehicle drivers to get a period very little less than two days at each web site and supply trainees educating certificates.
Business payment (accredited from Chamber of Business).
2- Technical justification for solution technicians heating and training unit drivers.
Indicators for heating systems in addition to index overload.
In situation of order, we require two certifications of starting that must be stamped from Saudi consular workplace in your country|
2- Letter from the supplier to provide 3 years service warranty for incinerators from shipping day. In addition of complimentary extra components ensure letter ought to endure for a single decade by the end day of assurance.
3- Offer certification that the incinerators are environmentally friendly as well as also attach evidence that environmental administration company in the nation of Origin as well as likewise your merchandise needs to be discharges cost-free as a result of the degree of degree of significance of its global air vents.
Alarm system Sensor at the event of (accidents “heater” or filtration gadget or heat leakage or interior connections as well as electric wiring).
– Isolation of shedding area: the area in between the wall surfaces must be of the “stainless-steel”. – Incinerators have actually to be fitted with a controller board of the electronic methods to keep an eye on all the necessary indicators of activation methods, as well as start-up as well as switch off so as to be divided inside a steel box with the occurrence of these:.
2- Technical justification for solution technicians heating and training unit drivers.
Records need to consist of all the information such as pamphlets, technical resources, operating, maintenance manuals, in addition to handouts taking good care of their key-board.
Location temperature degree sensors.

Needs and specs for the practice of supply, installation, performance and ensure the 3 incinerators for burning and incineration of medications as well as also harmful substances for customizeds branch


WASTE INCINERATOR


 

–          150 KG/HR

–          Compliant with EU rules, Directive 2000/76/EC

–          Fuel type: Diesel

–          Easy management and upkeep

–          Temperatures:

850 deg C for municipal waste

1000 deg C to clinical waste

1100 deg C for harmful waste containing halogenated organic materials with articles of chlorine or its compounds.


Medical Waste Burner PROPOSITION


Utility problem for the incineration gadgets conducting is your sticking to.

1) petrol: Light petroleum or Kerosene

two ) Electric Power

Electric Motor

-0.1– – 110kW: Air Conditioner 220V x 3PH x 50Hz

– – – – Here 0.1 kW: Air Conditioner 220V x 1PH x 50Hz Control Circuit

– – – – MCC control: A/C 220V x 1PH x 50Hz

– – – – Tool: Air Conditioner 220V x 1PH x 50Hz

– – – – Switch over Over Gear: Air Conditioning 220V x 1PH x 50Hz

2.

– – Switch Over Gear: Air Conditioning 220V x 1PH x 50Hz

2. Door -to-door transport, Installation, Commissioning and Training

3. Prices quote

– – Cost needs to be given in Ethiopian Birr (incl. VAT)

– – Price Should include extra cost elements such as products, insurance, installment and training for essential personnel, until approval liability where suitable

{
(adsbygoogle = window.adsbygoogle || []).push({});|}|

Utility problem for the incineration gadgets conducting is your sticking to.


Clinical Waste Incinerators


Incinerator nevertheless the measurement of chamber > > 2000 x >> 1200 mm. Prepare for burn FLUID Waste +/- 20 liter/hr.
C: The quantity of selection can we put in each individual day basis per 1 day.
The chamber of the burner ought to possess the ability to hold about 200 – – – – 250 kg of waste in an offered time. {
(adsbygoogle = window.adsbygoogle || []).push({});|}
4. We require just double chamber twin heating unit incinerator.
A; Establish Ability for every layout, how much bunches can we put in one-time. I require tio under stand in term of set load single I will ut in Kgs.
Continual by significant OIL Burner.waste disposal incinerator, together with the capacity of taking good care of both completely dry in addition to damp rubbish. That include house hold wastes along with leaves that are lost.
B: Burning capability per hr, to recognize simply just how much time it will surely take to melt one collection and what’s cooling timem each.|C: The quantity of selection can we put in each individual day basis per 1 day.

Incinerator nevertheless the measurement of chamber > > 2000 x >> 1200 mm. Prepare for burn FLUID Waste +/- 20 liter/hr.
5. Please send us DEFRA and DADR consent records by accessory, replicate of ISO along with recap of gas emmission report from drains.


incinerator plant specification


1) Power Supply:
( a) Keys Supply:
( I) Singular Stage supply; 220– – 240V, 50Hz( ii) 3 Stage supply; 380– – 415V, 50Hz( iii) The electricity source electrical socket (sockets) for solitary stage supply system in the hospital’s three pins as well as additionally adheres to BS1363. |}

(b) Change:-LRB- I) Keys modification is a usual concern, the operation requires to be influenced by this issue a resistance of ± 15% or more in both the nominal voltage should certainly be permitted.
( ii) Keys Cut-off (black out) is a regular issue. Where required, Uninterrupted Power Supply (UPS) System should be consisted of to remain clear of damages of gear as a result of sudden disruption in electricity supply.
( iii) There are spikes not necessarily from the secrets supply nonetheless results when specific plants or apparatus began.
( iv) Vendors need to as an outcome validate to make certain that their electricity supply systems will not be impacted by the aforementioned conditions.

two ) Supply Of Water a) High quality: the mains supply is tough water. The supplier requires to check/modify their gear with filters or descalers where required.
B ) Stress: this fluctuates and correlated with frequent eliminated. Where required, the corporation ought to consist of pumps or boosters to overcome this dilemma.
Needs

3) Temperature amount: ambient temperature level varieties in between 21– – 450 C or possibly far more in densely populated aerated places. The hottest month of the year is March. Environmental temperature level can be such that inferior rubber as well as also plastic things can melt or warped. Prospective buyers need to make certain all items will have the capacity to withstand such temperatures

4) Humidity: rust is generally high concerning 65– – 90 percent. Electronic gadgets should be secured to avoid the impact of condensation.

5) Dirt: this is a significant concern particularly during the dry period. Dust get in tools as well as congests filters. Additional security and protection has to be provided where essential along with where suitable added filters offered to last not less than 5 years continuous usage.

6) Vermin: these are additionally provided as well as sometimes take part in gear to chew cable television along with pee on boards to create short circuit. This can be stopped by using vermin shield where required to prevent entry of these destructive pets.
7) The suggested tools must accommodate today perfect global standard such as ISO; CE; IEC, ANSI and/or BS

8) Language: a) All tags along with markings on the resources need in order to be in English language. B ) All software program application programs in the suggested gadgets should remain in English language c) All handbooks need to remain in English language.

9) Each of the apparatus provided requirement to be provided with customer and additionally technological manuals. Guidelines on their usage, storage space as well as also remedy has to be clearly indicated in the handbooks and additionally where necessary, on the resources.

10) Where perfect the following will utilize: a) Electrical Security I) The instrument has to be provided a line (power) cable of acceptable sturdiness, size, ampacity, and also top quality as well as additionally has to be guarded with perfect strain and stress alleviations.
Ii) The device ought to include, or the bidder or distributor have to provide, power plugs that are adequate for the voltage and also current of the device.
Iii) The structure requires to be based as well as grounding resistance needs not to exceed 0.15 ohm.
Iv) If the machine is twin protected, it ought to be so classified.
V) Electrical leak current in the structure of this gadget should not exceed 500µA a IEC 601-1 b) Effects of Fluids

Location VI. Requires 2-84

I) Person as well as likewise operator safety and also security and protection as well as system efficiency need not to be detrimentally affected by liquid spills.
Ii) When the machine is influenced, it needs to fail securely.

c) Overcurrent Safety I) Loss of electricity to different other apparatus on the exact same branch circuit because of internal gear blunders need to be protected against by utilizing incorporates or breaker which are clearly labeled as well as easy to convert or replace.
Long-lasting markers near every fuse holder need to indicate fuse scores.
Of the very small line voltage of 220Volts.
Ii) The machine must not be harmed by voltages by -21% to +12.5% of the small line voltage of 220Volts.

e) Electromagnetic Disruption (EMI).
I) The tool’s performance should not be influenced by EMI discharged or carried out using the high-voltage line from one more instrument.
Ii) When the system is affected, it ought to fall short securely.

f) Alarms.
I) The device needs to have aesthetic or audible alert to recommend chauffeurs of any kind of sort of system mistake that might trigger harmful or erroneous results.
Ii) Audible and/or aesthetic indicators should certainly cause when the display reading gets to and stays in the security system limitation.
Iii) All alerts have to be completely clarified in the chauffeur’s guide.

gram ) Audible Alerts.
I) Audible alarm systems need to be distinctive along with readily recognized.
Ii) Distinct alarm systems should be made it possible for when the unit is turned on (i.e., the default need not to be readied to OFF) as well as ought to be clearly distinct at any sort of kind of amount setting.
Iii) If the alarm system quantity is flexible, it needs not to be feasible to turn down the quantity so minimized that it is not more than likely to be listened to.
Iv) Though an audible-alarm silence is okay, the alert must repeat automatically if the challenge isn’t handled.
V) When an alarm system is cluttered, a decorative display ought to clearly indicate which alarm system is burdened.

h) Cosmetic Safety system.
I) Visual security system should be basic to comprehend.

2-85 Location VI. Demands

ii) The alarm system needs to define to the problem as well as continue to be up until the alert problem is cared for; it needs not to be feasible to switch off the aesthetic alarmclock.

I) Structure and building Top-notch.
I) The machine really needs no sharp edges.
Ii) All external elements ought to be securely put.
Iii) The system needs to be secured along with supply suitable protection versus transferring as well as electrically stimulated components.
Iv) The machine should certainly be well constructed with long lasting products to defy common abuse along with cleanup.
V) Switches over, deals with, as well as various other controls must be designed for issues of hefty usage.
Vi) Electrical wiring and also tubes should be well arranged in addition to packed, if perfect. Vii) Mechanical, electric, along with electrical terminators, adapters, sockets, in addition to.
Solder joints should be created to prevent fluid infiltration, imprecise connections, and also mismating of perfect in addition to combinings.
Viii) Connections need to be risk-free to resist unintended disconnection as well as ought to protect sterility, when perfect. I) The controls (i.e., switches over, knobs, etc ) need to be noticeable in addition to merely established, and likewise their attributes have to be self-evident.
Ii) Device design needs to prevent false belief of display screens as well as likewise govern arrangements.
Iii) Buttons and additionally manages should certainly be secured versus unforeseen configuration adjustments (e.g., due to an individual cleanup versus the board ).
Iv) Controls requires to be sealed versus infiltration of liquids. I) Labels as well as markings should definitely be clear and similarly readable.
Ii) Labels and additionally markings must be springy sufficient to withstand normal cleansing as well as similarly normal wear.
Iii) Correct care tales should be provided on the device.

l) Ease of Usage and upkeep.
I) The machine has to be basic to learn to userun, and additionally keep.
Ii) The machine has to get abbreviated operating directions consisted of on or using the unit (e.g., on a laminated card affixed to the apparatus ).
Iii) The gadget has to be simple to tidy, sterilize, and/or decontaminate, as perfect. Iv) The device should be created for simple accessibility to functional components.

m) Unique maintenance tools, spare-parts along with consummables.
I) Where required or needed, the carrier must consist of any kind of kind of special tools required for the maintenance of the suggested gadgets.
Ii) Each apparatus ought to be given together with the advocated spare-parts

Location VI. Requires 2-86

needed for precautionary care for five years and where needed contain supply of supported spare-parts for rehabilitative care.
N) Training.
I) The seller is required to supply ample instruction on each tools on the suitable usage as well as procedure of their tools.
Ii) Likewise, suppliers are required to provide adequate vendor’s training about the installation as well as also maintenance( both preventative and curative ).
O) Merchandise packaging and Storage space Room Troubles of Devices.
I) The resources as well as components ought to take on temperature as well as also dampness extremes more inclined to be experienced throughout storage space as well as likewise transport.
Ii) The manufacturer must recommend treatments for storage of the tools.

6) Vermin: these are additionally offered as well as sometimes take part in gear to eat cable televisions as well as pee on boards to generate brief circuit.

{
(adsbygoogle = window.adsbygoogle || []).push({});

1) Power Supply:
( a) Keys Supply:
( I) Singular Stage supply; 220– – 240V, 50Hz( ii) 3 Stage supply; 380– – 415V, 50Hz( iii) The electricity source electrical socket (sockets) for solitary stage supply system in the hospital’s three pins as well as additionally adheres to BS1363. |}

(b) Change:-LRB- I) Keys modification is a usual concern, the operation requires to be influenced by this issue a resistance of ± 15% or more in both the nominal voltage should certainly be permitted.
( ii) Keys Cut-off (black out) is a regular issue. Where required, Uninterrupted Power Supply (UPS) System should be consisted of to remain clear of damages of gear as a result of sudden disruption in electricity supply.
( iii) There are spikes not necessarily from the secrets supply nonetheless results when specific plants or apparatus began.
( iv) Vendors need to as an outcome validate to make certain that their electricity supply systems will not be impacted by the aforementioned conditions.