small scale incinerator

Incinerators Biological waste disposal system (incinerator)

Incinerator must meet the following specifications:

–       Combustion capacity (kW) = 581 +/-10%

–       Combustion capacity (kcal/h) = 500,000 +/-10%

–       Max. l/h (at approx.. 50% water content) = 100 +/-10%

Further specifications will be provided with the inquiry.

The incinerator shall be fully self contained.

The incinerator plant shall incorporate a control panel for its operation. On the control panel we shall have a visual display of the chamber temperatures. This visual display must control and monitor the incinerator and his performance.

Capacity of destruction in weight shall be 60 Kg/h.

It should be able to operate not less than 10 hours/day

This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…

Design Specification : Types A, B, C, D, and E of medical waste

“PYROLYTIC” combustion, by controlling the gasification of waste.

The incinerator must avoid the release of black smoke and fine dust, during the loadings.

It shall be able to reduce the volume of wastes by 98%.

It shall be able to hold emission in the second burn with gas residence of not less than 2 seconds.

The incineration should be completely free from visible smoke as well as offensive odours.

1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.

The primary combustion chamber shall be constructed from heavy steel plate and the unit is internally lined with a complete layer of hote face refractory and high efficiency insulation.

The Internal diameter of the Chimney at least: ? 400 and its height: 8 m

The Volume of the combustion chamber at least: 1.200 L

The Dimension of the door for loading in cm at least: 70×70.

Burner operation should be Automatic On/Off
Fuel?: diesel

Manufacturer to provide  necessary information for the best of  the installation

The control panel shall have all appropriate audible and visual alarms to ensure safe operation.

This incinerator with “PYROLYTIC” combustion must have:
1.A combustion chamber of waste:
oPerfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load
oA burner of lighting which the use is limited to the ignition of waste.
oFrontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
oThe insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal.
o Composition of the refractory;

?Refractory concrete :
. Thickness    : ≥100 mm
. Nature: 42% of Al203
?Insulate in fibrous panels :
Thickness: ≥75 mm
Nature: Calcium silicate.
?Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
Plate of combustion in Carborundum, avoiding the fixing of glass and slags

A chamber of post combustion of gases
oA burner of combustion of gases,
oA device of injection of air allowing a total recombustion of gases,
oA device of air inlet of cooling of waste gases,
oA sheath of evacuation of the gases burnt.
oCarcass in strong sheet steel with support of connection.
oComposition of the refractory;
?Refractory concrete :
?Thickness    : ≥150 mm
?Nature: 65% of Al203
?Insulate in fibrous panel :
?Thickness: ≥85 mm
? Nature: Calcium
oBurner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
oA secondary injection of air to ensure perfect oxygen content.

A control box ensuring the complete cycle of combustion.

Fan:
oElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle.
Controls and regulations:
Control box watertight to dust, including:

A switch circuit breaker for each engine (ventilators and burners).
A timer with adjustable temporization for the regulation of each burner.
A regulator with digital watching for the temperature of combustion.
A regulator with digital watching for the temperature of post combustion.
Electric box

The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C)

Process Filtering system: Scruber to be mentionned as optional

china incinerator manufacturer and exporter


Primary Combustion Chamber
Waste Charging Door: Provided with refractory lining with sealing gaskets
Ash Removed Door: Provided with refractory lining with sealing gaskets
Outer Body MOC: Mild Steel, 5mm
Primary Chamber: Stainless Steel
Operating Temperature :800. ± 50◦C
Insulation: Insulation Brick
Heating Elements Type: Kanthal Al Grade
Power Consumption: 75 KW ( Initial Load )
Electrical Supply :3 Phase 440 Volt
Control Panel
MOC: Mild Steel Power Coated
No. of Temp: Controllers : 2 Nos
Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase.
I.D.Fan
Type: Centrifugal Type
MOC: Mild Steel
Capacity:2 HP/3Phase
Make of Motor: Kirloskar /Havells/Crompton
Combustion Air Fan
Type: Centrifugal Type
Capacity: 1HP/3Phase
Make of Motor: Kirloskar /Havells/Crompton


Hot sale small waste incinerators 30kgs and 50kgs per hour”


Items/Model TS30(PLC) TS50(PLC)
Burn Rate 30 kg/hour 50 kg/hour
Feed Capacity 60kg 100kg
Control Mode PLC PLC
Combustion Chamber 330L 560L
Internal Dimensions 75x75x60cm 100x80x70cm
Secondary Chamber 180L 280L
Smoke Filter Chamber Yes Yes
Feed Mode Manual Manual
Voltage 220V 220V
Power 0.5Kw 0.7Kw
Oil Consumption (kg/hour) 10.2–20 12.1–24
Gas Consumption (m3/hour) 9.8–20 9.9–26.1
Temperature Monitor Yes Yes
Temperature Protection Yes Yes
Oil Tank 100L 100L
Feed Door 55x50cm 70x55cm
Chimney 5Meter 5Meter
Chimney Type Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec.
Gross Weight 3000kg 4500kg
External Dimensions 175x120x140cm 230x130x155cm


Incineration’


Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long life. *based on sequence * High fever, long life of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 500kgs per hourto 6ton per day.  * PLC Control Plane. *based on order  * New Design for pet animal cremation business.  * One year warranty on incinerator and components in stock. 

Incinerator is a incineration equipment, direct fire waste by gasoline fuel or oi fuel. As different circumscription, incinerator may be termed many words as below: 

Therapy capacity: Small scale incinerator, big scale incinerator and incineration pant. 

Waste substance: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators 

Incinerator fuel: Gas incinerator, petroleum incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. 

Famous Incinerator maker company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 

Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 degree 800–1000 degree 800–1000 degree 800–1000 degree 800–1000 degree
2nd. Chamber Temperature 1000-1200 degree 1000-1200 degree 1000-1200 degree 1000-1200 degree 1000-1200 degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

3 Combustion Chambers MEDICAL WASTE INCINERATOR


Version

WS-35

Photo

Burning Price

Average 35 kgs/hour

Feed Capacity

Average 80 kgs

Main Combustion Chamber

460 Liters

Secondary Combustion Chamber

200 Litres

3rd Burning Chamber

200 Litres

Smoke Filter Chamber

Wet Scrubber System

Feed Mode

Manual

Voltage

220V

Electricity

2Kw

Gas Type

All-natural Gas/LPG

Heater

Italy Original

Oil Consumption (Diesel Oil)

***

Gas Consumption (Natural Gas)

Ordinary 24 m3n/hour

Internal Dimensions

110 x 70 x 60cm (key chamber)

Outside Dimensions

160 x 100 x 180cm (without Moist scrubber)

Temperature Screen

Yes

Oil Storage Tank Ability ( if oil gas)

***

Door Opening

50 x 50cm

Chimney Size

5.0 Meters

Smokeshaft Type

Stainless-steel

Equipment Gross Weight

5000 kgs

Procedure Technical Specifications

Key Chamber Temperature

800 ℃–– -1000 ℃

Additional Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Effectiveness

> 98%

Waste Lower Calorific Power

Primary chamber:
Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature 

sensor points with complete internal fans.
Secondary Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 

02 Sec gas residence times.
Third Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal 

fans. 02 Sec gas residence time.

HICLOVER – Medical Environmental 

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 


Air Emissions Environmental Standards CA

Air emission standards establish limits on the amount of contaminants that can be released into the atmosphere. These standards are expressed as a concentration in the exhaust gases leaving the stack and are capable of being achieved using generally available incineration technology and waste diversion practices. The following emission standards1 apply to existing, new or expanding solid waste incinerators operating in Nunavut and have been adopted from the Canadian Council of Ministers of the Environment (CCME) Canada-Wide Standards for Dioxins and Furans and Mercury Emissions, respectively.   Similar standards for the open burning of solid waste have not been established.

Table 1. Air Emission Standards for Solid Waste Incinerators

Parameter    Numeric Standard    Explanation

Dioxins and Furans
80 pg I-TEQ/cubic metre
Unit of measure is picograms of International Toxicity
Equivalents per cubic metre of air

Mercury
20 µg/Rcubic metre
Unit of measure is micrograms per Reference cubic metre (the volume of gas adjusted to 25oC and 101.3 kilopascals)

Opacity is the degree to which the exhaust gases reduce the transmission of light and obscure the view of any object in the background. It is expressed as a percentage representing the extent to which an object viewed through the gases is obscured. Although not an emission standard, opacity provides an indication of the general performance of the incinerator during normal operation2.  Opacity in the incinerator stack should not exceed 5%. While it is not anticipated that opacity levels would exceed 1% to 2% under normal operation, values greater than 5% indicate the incinerator is not performing properly and additional performance evaluation and adjustment is required.

Figure 6 – Examples of Smoke Opacity Ratings
The opacity ratings are estimates and are provided for illustrative purposes only
Centre and right photos courtesy of GNWT Department of Environment and Natural Resources

Waste Management Preparation


If burning and incineration is used, the devices picked need to be made as well as sized to match the waste produced, minimize fire danger and also result in the total burning of the waste.

The generator of a waste is responsible for its secure monitoring from cradle-to-grave. Using raw materials successfully and also minimizing the amount of waste generated is the most vital step in waste tracking preparation. For example, through enhanced waste administration groundwork, it may be possible to lower or remove the requirement to shed or blaze waste entirely. Undertaking a waste audit will certainly help to ascertain the kind and volume of waste being created, the expenses of current management options and check out chances for better handling the waste. This details will likewise likewise allow the generator to execute a waste administration regimen that is customized to its one-of-a-kind demands, place and also conditions.

Despite needing better waste reduction measures in place there’ll certainly be waste created. Waste by its character is normally a mix of different unwanted products. The segregation and recreation of various kinds of waste is an efficient method to lower the number of waste calling for expensive handling, storage, therapy and also disposal. Partition also makes it possible for the reuse of certain kinds of waste to get a various purpose. Reuse activities might be undertaken either on-site or off-site.

Treatment and disposal is the last step in effective waste administration and also must be taken on just besides other practical reduction and also reuse alternatives have been examined. A vast range of therapy and disposal choices exist and also each need to be examined prior to choosing a last strategy, no matter whether waste is to be treated as well as cared for onsite or off-site. If burning and incineration is your method of selection, equipment has to be created as well as sized accordingly to match the type as well as quantity of waste being produced. As explained in the adhering to segment, start burning is capable of securely destroying a restricted number of kinds of waste. While burners are capable of securely destroying a wider range of waste, a lot of kinds of waste must still be diverted. Because of this, on-site partition remains a vital part of any type of waste management plan.

Ordinarily, the following principles must be used to guide responsible powerful waste observation preparation:

Know your waste by doing a waste audit.


pet incinerator prices


Spare part list –After burners

Item description                                                No of required

Motor     2

Control box  2

Pump couplings   4

Photo cells    2

Sets ht. leads       2

Sets electrodes    4

Oil valve       1

Nozzle   2

 

Spare part list –Ram loader

Item description                                                No of required

Reed switch          4

Seal kit  1

 

Medical waste incinerator Accessories

-Clean out tools

-Loading and ash removal methods.

-Fuel storage tank with the two pump and all accessories.

-Flue gas cleaning system

-Stack discharge.

Medical waste incinerator civil work

-Construct incinerator foundation

-Provide stack support

-Provide open steel structure room for the incinerator.

Medical waste incinerator submittal shall include:-

-Detail installation drawing

-Incinerator and auxiliary product data

-Test reports

-Certificates like CE, ISO,LR, FNOR, TUV and UL

-Energy analysis report

-Project experience

-Pollution control equipment emission rate.

-Noise level limitation.

-Quality assurance

-guarantee