Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Incinerator Yd-500
Product Description
Model | YD-500 | ||||||
Burning Rate |
|
||||||
Feed Capacity | 800 kgs | ||||||
Primary Combustion Chamber | 4000 Liters | ||||||
Secondary Combustion Chamber | 1500 Liters | ||||||
Mix Combustion Chamber | Yes | ||||||
Smoke Filter Chamber | Yes | ||||||
Feed Mode | Manual | ||||||
Voltage | 220V/380V | ||||||
Power | 2.24Kw | ||||||
Fuel Type | Diesel Oil/ Natural Gas/LPG | ||||||
Burner | Italy Original | ||||||
Oil Consumption (Diesel Oil) | 31–59.1 kg/hour | ||||||
Gas Consumption (Natural Gas) | 19.2–64.2 m3/hour | ||||||
Internal Dimensions | 257 x 147 x 108cm (primary chamber) | ||||||
External Dimensions | 320 x 220 x 460cm (without chimney) | ||||||
Temperature Monitor | Yes | ||||||
Oil Tank Capacity(if oil fuel) | 500 Liters | ||||||
Door Opening | 108 x 128cm | ||||||
Chimney Length | 14.0 Meters | ||||||
Chimney Type | Stainless Steel | ||||||
Equipment Gross Weight | 13000 kgs | ||||||
Operation Technical Specifications | |||||||
Paimary Chamber Temperature | 800degree–1000degree | ||||||
Secondary Chamber Temperature | 1000degree-1200degree | ||||||
Residency Time | 2.0 Sec. | ||||||
Burning Efficiency | >98% | ||||||
Waste Lower Calorific Power | 3000Kcal |
Leading Waste Incinerator
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can use within this gear? A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation substance, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Remedy capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour)doesn’t indicate any waste material. China incinetor, china lab waste incinerators, china medical incinerator, china medical incinerators, china waste incinerator, clover incineter, clover medical ltd, The animal/pet combustion speed around 2/3 of typical capacity.
Clover incinerator use time per day up to 24 hours. Between every feed/combustion time, there are approximately 0.5-1 hours cooling time plus time to get feeding waste. Actual combustion time per day is about 16 hours. The lifetime of incinerator between 5-10 year based on use.
Generally, we proposal little laboratory, little clinic use capacity under 20 kgs per hour. If incinerator use in hospital, please calculate the waste output around 2kgs per individuals per day. If there are 200 sickbed at the clinic, that's mean you need 1 incinerator capacity around 400kgs per day, switch to power per hour is around 30-40 kgs per hour. According the operation time per day, waste material, funding, growth, etc, you can use capacity from 30-50 kgs per hour incinerator. *The best way to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We provide all documents and incinerators simple to installation and functionality. Customer can send individuals come to our factory to learn operation and installation. Generally, we don’t send engineer to neighborhood website or even request. The dispatch cost is additional based on order.
Q: Combustion Temperature A: The very first combustion chamber: 800-1000 centi level. The next combustion chamber: 1000-1200 centi level. PLC mode based on order and model.
Q: Operation and maintenance costs A: Operation cost based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according model, use situation.
One individual can service 02 unit incinerators. The staff should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and know threat of medical waste to safeguard worker self with essential protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Gas Cleaning Methods Maishima Incineration Plant
Basic Info.
Product Description
Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long life. *based on sequence * High fever, long life of incinerator. * Free or minimal installation on site. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. * PLC Control Plane. *based on order * New Design for pet animal cremation business. * One year warranty on incinerator and parts in stock.
Application Scope: 1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. 3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation
Nanjing Clover Medical Technology Co., Ltd.. Is a leading waste incinerator maker in China. We are local producer and one of the largest exporter of China. Pyrolytic incinerator gear technical is main waste treatment all the world, for Medical Waste, Animal Incineration, Pet cremation and other good wste. The capacity from 10kgs/Hr. To 500kgs/Hr. , up to 6ton per day. Presently, waste incineration plant saudi arabiawaste incineration technologey maker clover medical restricted, waste incinerator capacity of 10 to 30 a lot of day, we provide different series for local consumer requirements and layout updated incinerator with our leading technology. The updated design characteristic of our range of incinerators make them one of the most cost effective in the world.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Medical Incinerator Yd-50
Product Description
Incinerator is a incineration gear, direct fire waste by gasoline fuel or oi fuel. As different circumscription, incinerator could be named many words as under:
Therapy capacity: Small scale incinerator, large scale incinerator and incineration pant.
Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators
Incinerator fuel: Gas incinerator, petroleum incinerator
Waste to Energy (WTE): WTE incinerator, non-WTE incinerator
Incinerator Manufacturer: China incinerator producer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.
Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)
Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Items/Model | YD-30 | YD-50 | YD-100 | YD-150 |
Burning Rate (kgs/Hour) | 30 kgs/Hr. | 50 kgs/Hr. | 100 kgs/Hr. | 150 kgs/Hr. |
Feed Capacity (kgs) | 60 kgs | 150 kgs | 200 kgs | 300 kgs |
Equipment Weight | 2300 kgs | 4000 kgs | 4300 kgs | 7000 kgs |
Primary Chamber (Liters) | 360 | 900 | 1200 | 1500 |
Secondary Chamber (Liters) | 200 | 200 | 500 | 500 |
External Dimensions (cm) | 145x90x175 | 200x160x230 | 220x180x360 | 240x170x380 |
Internal Dimensions (cm) | 100x60x60 | 120x90x85 | 130x100x90 | 150x100x96 |
Oil Tank(Liters) | 200 | 300 | 300 | 500 |
Door Opening (cm) | 48 x 60 | 62 x 80 | 55 x 80 | 59 x 81 |
Chimney (M) | 5 | 5 | 10 | 10 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES |
1st. Chmaber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
2nd. Chmaber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |