Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can use within this gear? A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation substance, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Remedy capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour)doesn’t indicate any waste material. China incinetor, china lab waste incinerators, china medical incinerator, china medical incinerators, china waste incinerator, clover incineter, clover medical ltd, The animal/pet combustion speed around 2/3 of typical capacity.
Clover incinerator use time per day up to 24 hours. Between every feed/combustion time, there are approximately 0.5-1 hours cooling time plus time to get feeding waste. Actual combustion time per day is about 16 hours. The lifetime of incinerator between 5-10 year based on use.
Generally, we proposal little laboratory, little clinic use capacity under 20 kgs per hour. If incinerator use in hospital, please calculate the waste output around 2kgs per individuals per day. If there are 200 sickbed at the clinic, that's mean you need 1 incinerator capacity around 400kgs per day, switch to power per hour is around 30-40 kgs per hour. According the operation time per day, waste material, funding, growth, etc, you can use capacity from 30-50 kgs per hour incinerator. *The best way to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We provide all documents and incinerators simple to installation and functionality. Customer can send individuals come to our factory to learn operation and installation. Generally, we don’t send engineer to neighborhood website or even request. The dispatch cost is additional based on order.
Q: Combustion Temperature A: The very first combustion chamber: 800-1000 centi level. The next combustion chamber: 1000-1200 centi level. PLC mode based on order and model.
Q: Operation and maintenance costs A: Operation cost based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according model, use situation.
One individual can service 02 unit incinerators. The staff should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and know threat of medical waste to safeguard worker self with essential protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |