Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
laboratory incinerator china manufacturer
Solid waste to be incinerated
Cartons, rags, cotton and other wastes associated with generation of electricity loaded in the incinerator in
bags.
Loading capacity: At least 100 Kg / h
Start up fuel
Diesel Oil
2.3 Incinerator Supply
The incinerator shall be equipped with sludge pumps that allow homogenous flow of sludge to its burner. These pumps
shall deliver waste oil from the incinerator sludge mixing tank to the incinerator. Operation and control of these
pumps shall be fully automatic. A linear negative feedback control algorithm shall be used to adjust the feed rate of
the sludge pumps and hence vary the quantity of sludge being incinerated. The sludge line shall also be equipped with
appropriate self cleaning filter that will keep impurities away from the burner.
A sludge mixing tank equipped with a superheated water heater shall also be
provided. A Superheated water heater shall be provided to heat the waste oil to the inlet temperature required by the
incinerator. In case a superheated water heater
cannot be provided, an electric heater shall be provided for the tank. The tank shall also be equipped with a magnetic
level indicator, level switches and appropriate drain valves, separate overflow and vent pipes.
Characteristics of superheated water available at the power station are as follows; Pressure and temperature of
superheated water at supply manifold; P = 10 Bars, T = 150 Deg
Pressure and temperature of superheated water at return manifold; P = 8.5 Bars, T = 140 Deg
chinese incinerator manufacturers
In a simple design with a metal steel drum electric. including:
A cage for receipt of biomedical waste;
A combustion chamber with fireplace with a filter to retain ashes;
A cover;
An air supply;
A turbine allowing the supply of the air.
Combustion temperature: 1800 ° C. Compliance with European standards.
Comes with all necessary accessories
Supply of incinerator model PDR-18 with:
· Capacity 100 kg/hr of waste containing up to 85% moisture
? Two combustion chambers
· Two fully automatic, oil fired, pressure jet burners
· Panel board
· Diesel tank of capacity 250 It. with 2 diesel pipelines, filter and valve.
Type: for animals waste
Capacity: 30 kg per hours for a maximum load of 120 kg.
GLP Gas
Voltage: 110V-120V
Semiautomatic control board
Stainless steel chimney, 3.5 meters above the incinerator.
High temperature painting for all the incinerator.
Front door for loading and unloading.
Fuel Diesel Oil 8/ kerosene
Capacity (m3) 0.57
Ave Capacity 50 kg per hour
Ave time for Burnout 5 hrs
External Dimensions
Length 2000mm
Width 1100mm
Height including flue 3500mm
Door opening
Internal Dimensions
(primary chamber)
Length 1200mm
Width 620mm
Height 660mm
Operation
Min. operating temperature 9500C
Max. operating temperature 13200C
Residency time in second chamber 2.0 seconds
Weight 1850kgs
Ancillaries
Operating and maintenance manuals
Recommended Spare list
300 liter fuel tank
Plant burning rate – 100kg/hr
Fuel – Diesel oil – 35 sec Redwood
Overall dimensions are as follows:
Width 2261mm
Length 3264mm
Chimney Diameter – 390mm
Chimney Height – 8000mm
chinese incinerator manufacturers, We process 8-10 ton waste of sheep carcass and its byproduct per day. We are looking for the equipment: combustion burners(combined fuel supply:natural gas and diesel),control panel and filter system. The diameter of the incinerator is 20 cm. Lower calorific power of the waste is 4KW/KG. Heating power 4000KW
containerised high temp incinerator
Medical Waste Incinerator
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can utilize in this gear? A: This gear to medical waste, pet animal, Municipal waste, reside waste. Prohibit any volatile and radiation substance, liquid gas and waste waste. GB18484-2001.
Q: Treatment capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average power.
Clover incinerator utilize time daily to 24 hours. Between every feed/combustion time, you will find about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The life of incinerator between 5-10 year according to utilize.
Ordinarily, we proposition little lab, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, please compute the waste output around 2kgs per people per day. Pet cremation equipment prices, little medical waste incinerator, waste incinerator manufacturers, animal incinerator china, animal waste incinerator, If there are 200 sickbed in the hospital, that's imply you need 1 incinerator capability around 400kgs per day, change to power per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Meeting and Testing A: We provide all files and incinerators simple to installation and functionality. Client can send people visit our factory to find out operation and installation. Generally, we don’t send engineer to local website if not request. The dispatch price is additional according to order. The second combustion chamber: 1000-1200 centi degree. PLC mode according to model and order.
Q: Operation and maintenance costs A: Operation price according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according version, use situation.
One person can service 02 device incinerators. The team should have fundamental electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to safeguard worker self with necessary protection element.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Provide of Inclinators for Interim Arrival Domestic Terminal Project

Design, Manufacture, Supply, delivery to site, installation, testing & commission of All weather proof Passenger Inclinators in accordance to the Scope and outline specifications mentioned in Annexure
Spesifikasi Incinerator 100kg/jam
Spesifikasi dan Daftar Material
Dimensi dan Power Capacity
Nama Barang: INCINERATORType / Model: PWR-INC-KMN 10Kapasitas: 100kg/Jam (1 m3)Length: 288 cm Width: 147 cm Height: 163 cm Height of Chimney std: 700 cm TOTAL WEIGHT: 8000 cm Tool — timer: Digital Included Automobile AlarmFinishing: Sexy endured paint gas tank: 200 Liter Covering Element from steel: 3-8mm Banyaknya Burner: 2 pcs Banyaknya Blower: 2 pcs Max. Fuel consumption: 15-30 Liter/Jam Max. Elektric consumption: 1100 Watt Bahan bakar: Kerosene / Diesel (solar) Voltage: 220 V / 1 phase / 50 Hz
Substance
1. PANEL CONTROL
Type: Digital Buatan: Local KAMINE ( Panel dan Incinerator satu Merek)Voltage: 220 V / 1 phase / 50 Hz Safety operator: Emergency Stop System: Microkontroller Pengoperasian: Semi AutomaticTemperatur control: Digital Coupler TypeControl panel: Manual dan automaticTipe: Self Standing Sort / Wall Mounted TypeMaterial: Moderate steelThermocontrol: 2 (Dua) 1200 ºCSet of timer: 0- 2 jamTombol saklar: on/off
2. CONTRUCTIONS Fire Brick: SK 34Castable: R 16Castable: R 14Isolator: Insulating Brick serat tahan panas Keramik 1.450 ⁰ CElement from steel: 3-8 mmFinishing: Cat Fetalit coating, Epoxy Resin (hot-endured paint)Complete berat keseluruhan: 8.000 kgKetebalan Dinding Dalam: 21 Cm
3. DIMENSION OF CHAMBER (Dimensi Ruang Bakar)
Chamber 1 Ruang Bakar Utama: 100 x 100 x 98 cm = 980.000 cm3 = 0.98 m3Chamber two Ruang Bakar Kedua: 40 x 100 x 98 cm = 392.000 cm3= 0.39 m3
4. EXHAUST STACK (Chimney) – Diameter (inch): Ø 10″, 8″-Panjang: 700 cm (7 m) dari permukaan tanah -Cerobong pertama dengan platform Cor tipe MWHT-Material Mild steel ( Baja Hitam )
5. Suhu Control: Optimal – Model: Digital – Jumlah (device ): 2 (dua) device – Kontrol Mode: On-Off 2. Power Supply (volt / fase / / herts): 15A / / 220 V / 1 Phase / 50 Hz 3. Panel kandang: Mild Steel + powder coating 4. Thermocouple: K – Jumlah: 2 (dua) device – Bahan: Stainless Steel + Ceramic 5. Timer: 0-2 Jam 6. De-ashing: Guide 7. System pembuangan Abu 2 unit 6. PINTU Pintu: Baja ringan dan Linning dengan castable Method: Double lock system ( penguncian ganda )
7. AIR SUPPLY SYSTEM Model / Type: fan sentrifugal 3 “Kapasitas (m3/minute): 3.000 m3/mntStatis Tekanan (mmAq): 98 mmAqPower: 200 watt/unitJumlah (device ): 2 (dua)
8. FUEL SYSTEM Pembakaran Burner:Type: Gun type OM 2NBahan Bakar: Diesel Oil / KeroseneKonsumsi Bahan Bakar: 10-18 ltr / jamPower: 250 wattJumlah unit: 1 device
Type: Gun type OM 2NBahan Bakar: Diesel Oil / KeroseneKonsumsi Bahan Bakar: 10-18 ltr / jamPower: 250 wattJumlah unit: 1 device
9. THERMOCOPLERuang bakar pertama dan keduaTipe: KProtective tube: Stainless steel + ceramicMax. Temperature: 1200 ºCJumlah: 2 unitSistem pemberian umpan: ManualSistem pengeluaran hasil: Manual
10. TANGKI BAHAN BAKARMaterial: solid steel Kapasitas: 200 liter
Horizontal Autoclave 155 Liters
Sterilizing chamber: Steam-heated via double back wall with integrated steam generator
Door and lock: Hinged door with quick lock and safety lock
Door seal: Blow-out design, even closure, automatic return without vacuum system
Temperature measurement technology: 2 independent sensors for controlling the steam generator + 1 sensor for sterilizing chamber
Preheating key
Security key switch saves program settings
Sterilization phase indicators
Pressurized-air supply: integrated Compressor for door control circuit and pneumatic set valves
Feed water consumption per batch 0.7 to 5.6 liters
Cooling water consumption per batch for spent-steam condenser 10–25 l at temperatures 15 °C
Water-level control: Within the double back wall
Low-water safety fuse: Heater Over temperature monitor
Sterile venting: Membrane filter 0,2um, 0.1 m² hydrophobic, steam-sterillisable, retention 99.5%
Control circuits: separate for heater and door seal, process control and monitoring
Timer Program start by date and time
Selectable Acoustic alarm at program end
Transport security device for door
Three Autoclave able (Polypropylene or stainless steel) Pans 5-10L