Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Latest Product

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

laboratory incinerator china manufacturer


Solid waste to be incinerated

 

 

Cartons,  rags,  cotton  and  other  wastes  associated  with  generation  of  electricity loaded in the incinerator in

bags.

Loading capacity: At least 100 Kg / h

 

 

Start up fuel

 

 

Diesel Oil

 

 

 

2.3  Incinerator Supply

 

 

The incinerator shall be equipped with sludge pumps that allow homogenous flow of sludge to its burner. These pumps

shall deliver waste oil from the incinerator sludge mixing tank to the incinerator. Operation and control of these

pumps shall be fully automatic. A linear negative feedback control algorithm shall be used to adjust the feed rate of

the sludge pumps and hence vary the quantity of sludge being incinerated. The sludge line shall also be equipped with

appropriate self cleaning filter that will keep impurities away from the burner.

A  sludge  mixing  tank  equipped  with  a  superheated  water  heater  shall  also  be

provided. A Superheated water heater shall be provided to heat the waste oil to the inlet temperature required by the

incinerator. In case a superheated water heater

 

cannot be provided, an electric heater shall be provided for the tank. The tank shall also be equipped with a magnetic

level indicator, level switches and appropriate drain valves, separate overflow and vent pipes.

 

 

Characteristics of superheated water available at the power station are as follows; Pressure and temperature of

superheated water at supply manifold; P = 10 Bars, T = 150 Deg

Pressure and temperature of superheated water at return manifold; P = 8.5 Bars, T = 140 Deg


chinese incinerator manufacturers


In a simple design with a metal steel drum electric. including:
A cage for receipt of biomedical waste;
A combustion chamber with fireplace with a filter to retain ashes;
A cover;
An air supply;
A turbine  allowing the supply of the air.
Combustion temperature: 1800 ° C. Compliance with European standards.
Comes with all necessary accessories
Supply of incinerator model PDR-18 with:

·        Capacity 100 kg/hr of waste containing up to 85% moisture

?      Two combustion chambers

·        Two fully automatic, oil fired, pressure jet burners

·        Panel board

·         Diesel tank of capacity 250 It. with 2 diesel pipelines, filter and valve.
Type: for animals waste
Capacity: 30 kg per hours for a maximum load of 120 kg.
GLP Gas
Voltage: 110V-120V
Semiautomatic control board
Stainless steel chimney, 3.5 meters above the incinerator.
High temperature painting for all the incinerator.
Front door for loading and unloading.
Fuel    Diesel Oil 8/ kerosene
Capacity (m3)    0.57
Ave Capacity    50 kg per hour
Ave time for Burnout     5 hrs
External Dimensions
Length    2000mm
Width    1100mm
Height including flue    3500mm
Door opening
Internal Dimensions
(primary chamber)
Length    1200mm
Width    620mm
Height     660mm
Operation
Min. operating temperature    9500C
Max. operating temperature    13200C
Residency time in second chamber    2.0 seconds
Weight    1850kgs
Ancillaries
Operating and maintenance manuals
Recommended Spare list
300 liter fuel tank
Plant burning rate – 100kg/hr

Fuel – Diesel oil   – 35 sec Redwood

Overall dimensions are as follows:

Width    2261mm

Length  3264mm

Chimney Diameter  –  390mm

Chimney Height      –  8000mm
chinese incinerator manufacturers, We process 8-10 ton waste of sheep carcass and its byproduct per day. We are looking for the equipment: combustion burners(combined fuel supply:natural gas and diesel),control panel and filter system. The diameter of the incinerator is 20 cm. Lower calorific power of the waste is 4KW/KG. Heating power 4000KW


containerised high temp incinerator

1.A two chamber high temperature incinerator for burning hazardous wastes.
a.As a guess I think we would be looking at burning somewhere in the order of 50kg per day of primarily oil filters and oily rags but will contain some oily sludge/waste oil, medical waste, thinners, paint sludge etc.  However it would be good to do it in larger batches so do not have to turn on every day.
b.We will not be burning general plastics, cardboard paper etc in this unit.
2.Diesel is available on site as a fuel supply for the incinerator;
3.Temperature in the first chamber ranges from 800-1,050oC;
4.Temperature in the first chamber ranges from 1,000-1,200oC;
5.The minimum retention time in the second chamber is 2 seconds;
6.Equipped with temperature probes and data loggers which will enable temperatures in areas of interest such as the primary combustor, secondary chamber to be recorded;
7.Equipped with sampling ports to enable discharge monitoring of air emissions if required;

Medical Waste Incinerator


Basic Info.

Model NO.:30kg/hr medical incinerators
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What’s kind of waste can utilize in this gear?  A: This gear to medical waste, pet animal, Municipal waste, reside waste. Prohibit any volatile and radiation substance, liquid gas and waste waste.  GB18484-2001. 

Q: Treatment capacity  A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average power. 

Clover incinerator utilize time daily to 24 hours. Between every feed/combustion time, you will find about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The life of incinerator between 5-10 year according to utilize. 

Ordinarily, we proposition little lab, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, please compute the waste output around 2kgs per people per day. Pet cremation equipment prices, little medical waste incinerator, waste incinerator manufacturers, animal incinerator china, animal waste incinerator, If there are 200 sickbed in the hospital, that's imply you need 1 incinerator capability around 400kgs per day, change to power per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator.  *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Meeting and Testing  A: We provide all files and incinerators simple to installation and functionality. Client can send people visit our factory to find out operation and installation. Generally, we don’t send engineer to local website if not request. The dispatch price is additional according to order.  The second combustion chamber: 1000-1200 centi degree.  PLC mode according to model and order. 

Q: Operation and maintenance costs  A: Operation price according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according version, use situation. 

One person can service 02 device incinerators. The team should have fundamental electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to safeguard worker self with necessary protection element. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Provide of Inclinators for Interim Arrival Domestic Terminal Project


CMC Services for Inclinators for 3 years including all spares, consumables, Skilled Manpower, tools and tackles all complete. As per Scope attached as Annexure
Design, Manufacture, Supply, delivery to site, installation, testing & commission of All weather proof Passenger Inclinators in accordance to the Scope and outline specifications mentioned in Annexure
Spesifikasi Incinerator 100kg/jam

Spesifikasi dan Daftar Material

Dimensi dan Power Capacity

Nama Barang: INCINERATORType / Model: PWR-INC-KMN 10Kapasitas: 100kg/Jam (1 m3)Length: 288 cm  Width: 147 cm  Height: 163 cm  Height of Chimney std: 700 cm  TOTAL WEIGHT: 8000 cm Tool — timer: Digital Included Automobile AlarmFinishing: Sexy endured paint gas tank: 200 Liter Covering Element from steel: 3-8mm Banyaknya Burner: 2 pcs  Banyaknya Blower: 2 pcs Max.  Fuel consumption: 15-30 Liter/Jam Max.  Elektric consumption: 1100 Watt  Bahan bakar: Kerosene / Diesel (solar)  Voltage: 220 V / 1 phase / 50 Hz  

Substance

1.  PANEL CONTROL

Type: Digital Buatan: Local KAMINE ( Panel dan Incinerator satu Merek)Voltage: 220 V / 1 phase / 50 Hz  Safety operator: Emergency Stop System: Microkontroller Pengoperasian: Semi AutomaticTemperatur control: Digital Coupler TypeControl panel: Manual dan automaticTipe: Self Standing Sort / Wall Mounted TypeMaterial: Moderate steelThermocontrol: 2 (Dua)  1200 ºCSet of timer: 0- 2 jamTombol saklar: on/off

2.  CONTRUCTIONS    Fire Brick: SK 34Castable: R 16Castable: R 14Isolator: Insulating Brick serat tahan panas Keramik 1.450 ⁰ CElement from steel: 3-8 mmFinishing: Cat Fetalit coating, Epoxy Resin (hot-endured paint)Complete berat keseluruhan: 8.000 kgKetebalan Dinding Dalam: 21 Cm

3. DIMENSION OF CHAMBER (Dimensi Ruang Bakar)

Chamber 1 Ruang Bakar Utama: 100 x 100 x 98 cm = 980.000 cm3 = 0.98 m3Chamber two Ruang Bakar Kedua: 40 x 100 x 98 cm = 392.000 cm3= 0.39 m3

4.  EXHAUST STACK (Chimney)         –     Diameter (inch): Ø 10″, 8″-Panjang: 700 cm (7 m) dari permukaan tanah -Cerobong pertama dengan platform Cor tipe MWHT-Material Mild steel ( Baja Hitam )

5.  Suhu Control: Optimal                           – Model: Digital                           – Jumlah (device ): 2 (dua) device – Kontrol Mode: On-Off                      2.  Power Supply (volt / fase / / herts): 15A / / 220 V / 1 Phase / 50 Hz                      3.  Panel kandang: Mild Steel + powder coating                      4.  Thermocouple: K                           – Jumlah: 2 (dua) device – Bahan: Stainless Steel + Ceramic                      5.  Timer: 0-2 Jam                      6.  De-ashing: Guide 7.  System pembuangan Abu 2 unit 6.  PINTU Pintu: Baja ringan dan Linning dengan castable Method: Double lock system ( penguncian ganda )

7.  AIR SUPPLY SYSTEM Model / Type: fan sentrifugal 3 “Kapasitas (m3/minute): 3.000 m3/mntStatis Tekanan (mmAq): 98 mmAqPower: 200 watt/unitJumlah (device ): 2 (dua)

8.  FUEL SYSTEM Pembakaran Burner:Type: Gun type OM 2NBahan Bakar: Diesel Oil / KeroseneKonsumsi Bahan Bakar: 10-18 ltr / jamPower: 250 wattJumlah unit: 1 device

Type: Gun type OM 2NBahan Bakar: Diesel Oil / KeroseneKonsumsi Bahan Bakar: 10-18 ltr / jamPower: 250 wattJumlah unit: 1 device

9.  THERMOCOPLERuang bakar pertama dan keduaTipe: KProtective tube: Stainless steel + ceramicMax.  Temperature: 1200 ºCJumlah: 2 unitSistem pemberian umpan: ManualSistem pengeluaran hasil: Manual

10.  TANGKI BAHAN BAKARMaterial: solid steel       Kapasitas: 200 liter

Horizontal Autoclave 155 Liters
Sterilizing chamber:  Steam-heated via double back wall with integrated steam generator
Door and lock:  Hinged door with quick lock and safety lock
Door seal: Blow-out design, even closure, automatic return without vacuum system
Temperature measurement technology: 2 independent sensors for controlling the steam generator + 1 sensor for sterilizing chamber
Preheating key
Security key switch saves program settings
Sterilization phase  indicators
Pressurized-air supply: integrated Compressor for door control circuit and pneumatic set valves
Feed water consumption per batch 0.7 to 5.6 liters
Cooling water consumption per batch for spent-steam condenser 10–25 l at temperatures 15 °C
Water-level control:  Within the double back wall
Low-water safety fuse: Heater Over temperature monitor
Sterile venting:  Membrane filter 0,2um, 0.1 m² hydrophobic, steam-sterillisable, retention  99.5%
Control circuits: separate for heater and door seal, process control and monitoring
Timer Program start by date and time
Selectable Acoustic alarm at program end
Transport security device for door 
Three Autoclave able (Polypropylene or stainless steel) Pans 5-10L 


Clover's Social Media