Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Latest Product

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

Oil Waste Incinerator


Basic Info.

Model NO.:Pet Crematory Equipment
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What’s kind of waste may utilize in this equipment?  A: This equipment for medical waste, pet animal, Municipal waste, reside squander. Prohibit any volatile and radiation material, liquid gas and waste waste.  GB18484-2001. 

Q: Remedy capacity  A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not indicate any waste material. The animal/pet combustion rate around 2/3 of ordinary power. 

Clover incinerator utilize time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time plus time for feeding squander. Incinerator combustion room photo, incinerator crematory, incinerator dealers, incinerator diesel fired, incinerator for medical waste, incinerator for medicial waste, Actual combustion time daily is around 16 hours. The life of incinerator involving 5-10 year based on utilize. 

Ordinarily, we proposal small laboratory, small clinic use capability under 20 kgs per hour. If incinerator use in hospital, then please calculate the waste output capacity around 2kgs per individuals every day. If there are 200 sickbed at the hospital, that's mean you need 1 incinerator capability around 400kgs every day, switch to power per hour is approximately 30-40 kgs per hour. According the operation time every day, waste material, funding, development, etc, you may use capacity from 30-50 kgs per hour incinerator.  *How to calculate Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Meeting and Testing  A: We supply all documents and incinerators easy to installation and functionality. Client can send individuals visit our factory to learn installation and operation. Generally, We do not send engineer to local website if not request. The dispatch cost is additional based on order. 

Q: Combustion Temperature  A: The very first combustion chamber: 800-1000 centi level.  The second combustion chamber: 1000-1200 centi level. 

Q: Incinerator Control Mode  A: Default Control manner is common control case. PLC mode based on model and order. 

Q: Operation and maintenance costs  A: Operation cost based on fuel consumption rate and power/staff, etc. 

Annual approximately $500-$1000USD annually maintenance according model, utilize situation. 

One individual can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation consumer guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency period in combustion chamber  A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day


hot medical waste disposing machine, Operation Condition: 8-16 hr/ day 
Control: Built-in data recording
Operating temperature: Incinerator 
/Primary Combustion Chamber
Primary Chamber: 900 – 1200 0C


Type: horizontal/vertical
Temperature:  1200- 1300 oC
Residence time of gases : >2 seconds
Ash Residue: <5% of original waste size
Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash
Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity
Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc 
Auxiliary device: Fuel cut-off device
Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                      
Chimney (Stack):
Type: Vertical type
height:>7 meter’
Material: Fireproof cast, stainless steel
OUTPUT: 
GAS- SMOKELESS,ODORLESS 
ASH -Max <5% of original waste size
Reduction of Pollutant gas SO2, HCL, HF and line particulate
Emission standard:
WHO/ European
Test report for emission testing provided?
Heat exchange mode: Automatic

Type: Constant loading, Best LoadingCapacity/Burn Speed per hour: 250 -300 kg/hr Substance:External- 3 layers Internal lining:  a fire proof Substance of pre-fired refractory bricks Using Aluminium lining, resistant to corrosive waste or gas and to thermal shockSecondary Combustion Chamber:


Containerized Kind Pre-Assembled Mobile Medical Facility Waste Burner Model CA100


Items/Model

CA100

Photo

Concept

Medical Waste Incineration Therapy

Burn Rate

Standard 100 kg/hour

Feed Capacity

Average 200kg/feeding

Control Putting

PLC( Programmable Reasoning Controller Incinerator)

Burning Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Handbook

Voltage

220V

Power

1.3 Kw

Oil Utilization (kg/hour)

Average 20.4 Kgs/Hour

Gas Utilization (m3/hour)

***

Temperature Level Screen

Digital Show

Temperature Level Defense

Yes

Oil Tank

200L

Feed Door

80x60cm

Chimney

5Meter

Chimney Type

Stainless-steel

1st.

800 ℃–– -1000 ℃

2nd. Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

Exterior Measurements

HICLOVER – Medical Environmental 

260x150x180cm


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 


Debaye Over Dioxin Emission From Waste Incineration


Basic Info.

Model NO.:incinerator double chamber 100kg per hour manufac
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Nanjing Clover Medical Technology Co., Ltd..

INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer

hospital for burning hazardous waste and chimicals

use in the hospital for burning hazardous waste and chimicals, minimum Capacity 300 per hour. I will be reselling to my client?. Below is the information I was given and nothing else. The hospital incinerator for use in the clinical waste as required by international environmental management. Minimum 300 Kg capacity/hr, Fuel fired, refractory lined, chimney and sampling prot. Minimum temperature of 1100 degree Celsiu.the incinerator machine for burn 500kg per hour. project about burn medical waste of the hospitals.Just want to price of you various types of Medical Rubbish Incinerators.need all information on 300 kg per hour unit.  availability.  operational costs using diesel (other).the waste is Human Tissues. And we have 10 kg per day; we need incinerator for medical waste.Burn Capacity: 50kgs per hour (Average capacity according to Medical Waste).please forward information about pricing on all of you pet crematory models.Regarding Gas Incinerator, Please note that Fuel for the Incinerator
will be Gas. As gas is chip in our country.

Clover's Social Media