30kgs rate 60kgs feed oil and also burner tiny waste burner


30kgs rate 60kgs feed oil and gas burner small waste incinerator for Afghanistan

Machine Working setting

Oil or Gas + Power

Voltage

220V

Oil usage (lit/hour)

Typical 13.3 lit/hour/chamber

Gas consumption (NG) (m3/hour)

16.0 (m3/hour) (NG)

Gas intake (LPG) (m3/hour)

11.7 (m3/hour) (LPG)

Burning rate

Ordinary 30kg/hour

Feed setting

Hand-operated

Key Combustion chamber

360 Liters

Second Burning chamber

200 Liters

Combustion Chamber Product

Refractory Concrete Cement+ firebrick

Interior dimensions

Yes (Main chamber)

External measurements

210x120x210cm( without smokeshaft)

Door opening

48X60 centimeters

Fuel Kind

Diesel Oil/ Gas/ LPG

Burner

Initial

Smokeshaft size

13.0 Meters

Smoke filter chamber

Yes

Temperature monitor

2 number Digital Show

Temperature level protection

Yes

Oil container

200L

Burning Performance

>> 98%

Chimney type

Stainless-steel

1st. chamber temperature

800c– 1000c

second. chamber temperature level

1000c– 1200c

Residency time

2.0 sec.

Gross weight

4000kg

Electric Plastic as well as glasses Shredder

Yes

Scrubber

Yes

Service Warranty Period

1. year

Main combustion chamber

Yes

Secondary burning chamber

Yes

Incinerator control situation

S. steel

Incinerator chimney

Initial

Gas Heater

Yes

Oil Storage tank ability

Yes

Oil Stand assistance

Yes

Dry Smoke Filter Chamber

Yes

Air Follower

Yes

Overall waste incineration capacity/time

Minimum 60KG

for Ministry of Public Wellness, Kabul, Afghanistan

animal incinerator for poultry usage 
burning rate around 150 kg/hr 
load capacity around 350 kg .
Municipal waste incinerator for waste production rate of 50 ton/day
Medical waste incinerator for waste production rate of 200 kg/day
Medical waste incinerator for waste production rate of 500 kg/day
Medium Unit – to handle an average waste production of 500 kg/day and meet the capacity
Automatic PLC controller incinerator plant with Dual heat burners and dual chamber.
Burning capacity up to 30 Kg per hour.
Water showering cyclone air cleaner 
Stain less steel 304 grade sheet for water scrub chamber 
Time up to 250 mints.
Fully automatic electric control circuit with timers
Primary temperature up to 850 deg C
Secondary temperature up to 1100 deg C
Manual/automatic loading /unloading
Automatic start at power fail during process 
Fast temperature rise control automatic detects fast burning materials and save burner fuel consumption by turn off /on burner automatically.
Suitable for waste of hospitals
Number of burner   2 Nos
Voltage  440 V 50 Hz
Operational enjoinment          5 C 60 C Humidity 10 C 90%
Fuel type               Natural gas Number of chamber      02 Nos 

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-30


burner manufacturer 200kgs/h



Waste is thermally rotted in the main chamber at temperature degrees of 800 ° C +. The resulting aeriform products are entirely oxidized in the second chamber at higher temperature levels with ample resident time. Various other specs are as adheres to. A burning chamber of waste:

* Flawlessly limited door for the hands-on loading of waste. The filling should certainly be Handbook, Set Tons

* A heater of lights which the use is restricted to the ignition of waste.

* Frontage of packing with door seals risen on hinges, wheel of screw plug, versatile joint, in addition to packing securing out of refractory.

* The insulation of the burning chamber need to be comprised of refractory blocks, having a high internet material of light weight aluminum as well as guards blocks in order to assure a minimum temperature level on the outside sheet steel.

* Composition of the refractory

Burning Capability

Max. 200kgs/h

Supporting Gas

Diesel

Kind of Heating Unit

Monoblock automatic heating units

Temperatures

Key Chamber: 800 ° C ± 50 ° C. Extra Chamber: 1300 ° C ±

50 ° C. Kind.

240 W.

Pump pressure.

* Make-up of the refractory

Burning Capacity

Max. 200kgs/h

Sustaining Gas

Diesel

Kind of Heating System

Monoblock automated heating systems

Temperatures

Main Chamber: 800 ° C ± 50 ° C. Extra Chamber: 1300 ° C ±

50 ° C. Kind.

Refractory thickness.

240 W.

Pump stress.

Refractory thickness.

115 mm thick.

Product.

Refractory blocks.

Insulation density.

50 mm thick.

Type.

Centrifugal.

Inflection.

Manual damper control.

Product of Construction.

Mild Steel.

Sort of temperature controller.

Digital.

End up & & paint kind.

Dual coat.

Material of construction & & capacity

. Mild Steel/ Plastic, appropriate capacity.

Other Standard Accessories.

Diesel oil degree sign, piping with shutoffs & & Non-return shutoff.

Aesthetic Monitoring of Gas.

Offered.

No. of Burners.

2 one in primary and also in second chamber).

Type & & Design

. Monoblock automated oil fired.

Make.

Riello.

Fuel.

Diesel.

Fuel shipment.

10 C 20 kg/h.

Discharging phase.

1.

Thermal power.

118 C 236 kW.

Motor power.

240 W.

Pump pressure.

10 C 12 bar (basic calibration), Max. pressure 15 bar.

Electrical supply.

Single phase 220V, 50Hz.

Material of building and construction.

Burned bricks.

Height.

9 meters from ground degree.



mobile burner



  1. Petrol: diesel
  1. Consumption: 8-10liter/hour
  1. Capacity: to cremate (carrion and spoils) 350-400kg/hour
  1. Temperature: 900-1350?C
  1. Operation temperature: -30~40?C
  1. Incinerator weight: 1800-2000 kg
  1. Volume: 0.70-0.80m/cube
  1. Exterior dimension: 1.4-1.6*1.0-1.15m (L*W)

A heater stands for a complete service to the problem of disposal of all clinical facility waste kinds. The fluid fuel

is diesel. The burner ought to meet the setup requirements. Expected Technical specifications

The burner will be totally self included. incinerators that are stainless

steel with destruction rate of 15kg per hr. bactch lots of 10-15kg of

waste in addition to average temperature degree of 8500 degress c.



Supply of Inclinators for Interim Arrival Domestic Terminal Project


CMC Services for Inclinators for 3 years including all spares, consumables, Skilled Manpower, tools and tackles all complete. As per Scope attached as Annexure
Design, Manufacture, Supply, delivery to site, installation, testing & commission of All weather proof Passenger Inclinators in accordance to the Scope and outline specifications mentioned in Annexure
Spesifikasi Incinerator 100kg/jam

Spesifikasi dan Daftar Material

Dimensi dan Power Capacity

Nama Barang: INCINERATORType / Model: PWR-INC-KMN 10Kapasitas: 100kg/Jam (1 m3)Length: 288 cm  Width: 147 cm  Height: 163 cm  Height of Chimney std: 700 cm  TOTAL WEIGHT: 8000 kg Panel — timer: Digital Included Auto AlarmFinishing: Sexy suffered paint Fuel tank: 200 Liter Covering Element from steel: 3-8mm Banyaknya Burner: 2 pcs  Banyaknya Blower: two pcs Max.  Gas consumption: 15-30 Liter/Jam Max.  Elektric consumption: 1100 Watt  Bahan bakar: Kerosene / Diesel (solar)  Voltage: 220 V / 1 phase / 50 Hz  

Substance

1.  PANEL CONTROL

Sort: Digital Buatan: Local KAMINE ( Panel dan Incinerator satu Merek)Voltage: 220 V / 1 phase / 50 Hz  Safety operator: Emergency Stop System: Microkontroller Pengoperasian: Semi AutomaticTemperatur controller: Digital Coupler TypeControl panel: Manual dan automaticTipe: Self Ranking Type / Wall Mounted TypeMaterial: Moderate steelThermocontrol: two (Dua)  1200 ºCSet of timer: 0- 2 jamTombol saklar: on/off

2.  EXHAUST STACK (Chimney)         –     Diameter (inch): Ø 10″, 8″-Panjang: 700 cm (7 m) dari permukaan tanah -Cerobong pertama dengan system Cor tipe MWHT-Material moderate steel ( Baja Hitam )

5.  INSTRUMENTATION & KONTROL                      1.  Suhu Control: Optimal                           – Model: Digital                           – Jumlah (device ): 2 (dua) device – Kontrol Mode: On-Off                      2.  Power Supply (volt / fase / herts): 15A / 220 V / 1 Phase / 50 Hz                      3.  Panel kandang: Mild Steel + powder coating                      4.  Thermocouple: K                           – Jumlah: 2 (dua) device – Bahan: Stainless Steel + Ceramic                      5.  De-ashing: Guide 7.  System pembuangan Abu two unit 6.  PINTU Pintu: Baja ringan dan Linning dengan castable System: Double lock program ( penguncian ganda )

7.  AIR SUPPLY SYSTEM Model / Form: enthusiast sentrifugal 3 “Kapasitas (m3/minute): 3.000 m3/mntStatis Tekanan (mmAq): 98 mmAqPower: 200 watt/unitJumlah (device ): 2 (dua)

8.  FUEL SYSTEM Pembakaran Burner:Sort: Gun kind OM 2NBahan Bakar: Diesel Oil / KeroseneKonsumsi Bahan Bakar: 10-18 ltr / jamPower: 250 wattJumlah unit: 1 unit 

Sort: Gun kind OM 2NBahan Bakar: Diesel Oil / KeroseneKonsumsi Bahan Bakar: 10-18 ltr / jamPower: 250 wattJumlah unit: 1 unit 

9.  THERMOCOPLERuang bakar pertama dan keduaTipe: KProtective tube: Stainless steel + ceramicMax.  Temperature: 1200 ºCJumlah: two unitSistem pemberian umpan: ManualSistem pengeluaran hasil: Guide

10.  TANGKI BAHAN BAKARMaterial: Mild steel       Kapasitas: 200 liter

9. THERMOCOPLE
Ruang bakar pertama dan kedua
Tipe : K
Protective tube : Stainless steel + ceramic
Max. temperature : 1200 ºC
Jumlah : 2 unit
Sistem pemberian umpan : Manual
Sistem pengeluaran hasil : Manual

10. TANGKI BAHAN BAKAR
Material : Mild steel
       Kapasitas : 200 liter

Horizontal Autoclave 155 Liters
Sterilizing chamber:  Steam-heated via double back wall with integrated steam generator
Door and lock:  Hinged door with quick lock and safety lock
Door seal: Blow-out design, even closure, automatic return without vacuum system
Temperature measurement technology: 2 independent sensors for controlling the steam generator + 1 sensor for sterilizing chamber
Preheating key
Security key switch saves program settings
Sterilization phase  indicators
Pressurized-air supply: integrated Compressor for door control circuit and pneumatic set valves
Feed water consumption per batch 0.7 to 5.6 liters
Cooling water consumption per batch for spent-steam condenser 10–25 l at temperatures 15 °C
Water-level control:  Within the double back wall
Low-water safety fuse: Heater Over temperature monitor
Sterile venting:  Membrane filter 0,2um, 0.1 m² hydrophobic, steam-sterillisable, retention  99.5%
Control circuits: separate for heater and door seal, process control and monitoring
Timer Program start by date and time
Selectable Acoustic alarm at program end
Transport security device for door 
Three Autoclave able (Polypropylene or stainless steel) Pans 5-10L 


Little Waste Incinerators 30 and 50kgs


we produce small scale waste incinerators, the capacity from 10kgs,20kgs,30kgs,50kgs,100kgs per hour.

Key Features:
* Stainless Steel chimney/stack, long lifetime.
* All versions with Dual combustion room.
* One year guarantee on incinerator and parts in stock.
* High temperature, long lifetime of incinerator.
* Free or minimal installation on site.

small waste incinerator


Medical Waste Incineration Plant


Product Description

Nanjing Clover Medical Technology Co., Ltd..

Item Specification
Model TS50 PLC
Main Product List per 01 set Primary Combustion Chamber
Secondary Combustion Chamber
Smoke Filter Chamber
Incinerator PLC Control Case
Chimney:5.0Meters
*(upgrade to Stainless Steel, free cost)
Italyoil/gas burner: 02 units
Oil Tank (if oil fuel): 100Liters

PLC( Programmable Logic Controller), Smart and Automated operation. Set combuston time based on different waste material and incinerator cease combustion .

Waste Incineration Therapy BURNING PRICE: 100-150kgs per hr HICLOVER TS150


BURNING RATE: -100 -150 kgs per hour

MINIMUM OPERATING TEMPERATURE: 800-1000 oC (PRIMARY BURNING)

MAX OPERATING TEMPERATURE LEVEL: 1000-1200 oC (AFTER HEATER BURNING)

SECONDARY MELTING CAPABILITY: COMPULSORY

DENSITY INSULATION: 50 mm high

Refractory capability: minutes 114mm

STURDY REFRACTING LINING TO WITHSATND 17500C

AVEARGE BURN OUT TIME: MAXIMUM 3HRS

GAS TYPE: FUEL OIL (DIESEL)

FUEL INTAKE IN LTRS/HR: average 14

RESIDNECY TIME IN SECONDARY CHAMBER: 2 PHASES

Items/Model

TS150( PLC)

Photo

Concept

Waste Incineration Treatment

Burn Price

Standard 100-150 kg/hour

Feed Capability

Standard 750kg/feeding

Control Setting

PLC( Programmable Reasoning Controller Incinerator)

Chamber Material

High Alumina Fire Brick Wall, 1750 ℃ Rate

Paint for outdoors face

800 ° C Price

Burning Chamber

1570L

Inner Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Guidebook

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Consumption (Liter/hour)

Ordinary 14( D.O)

Gas Intake (m3/hour)

***

Temperature Screen

Digital Show

Temperature Level Defense

Yes

Oil Tank

2000L

Feed Door

80x60cm

Chimney

10Meter

Smokeshaft Kind

Stainless Steel

1st. Chamber Temperature

800 ℃–– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

Exterior Dimensions

300x160x280cm( without chimney)



HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-28


animal incinerators


The incinerator shall be equipped with a Diesel oil tank that will be supplied with DO from our DO tank located in the

power station. The tank shall be equipped with level switches and appropriate solenoid valves for automatic filling of

the tank. The tank shall also be equipped with a magnetic level indicator, level switches and appropriate drain valves,

separate overflow and vent pipes.

Oil-fired multi-stage waste incinerator of pyrolytic type shall be installed complete with interconnecting flue gas

ductwork between the incinerator and the chimney outlet.

 

The unit shall be manufactured in accordance with the latest ASME code, BS and DIN standards.

 

The waste disposal shall be environmentally acceptable and the incineration emission shall comply with the admissible

emission limits (international EC-Standards). The visibility of flue gases shall not exceed one Ringelmann. The waste

shall be completely burnt and the content of un burnt organic matter of the ash shall not exceed 3%.

 

The unit shall allow for a minimum of 2.0 seconds retention time.

 

1.2        QUALITY ASSURANCE:

 

  1. Coordinate the entire assembly of incinerator, stack, controls, fuel supply.

 

  1. Provide written certification that the entire assembly has been coordinated to achieve the required performance

and to provide the required features.

 

  1. Equipment, installation, and operation shall conform to NFPA 82. Where conflicts exist between NFPA 82 and this

specification, this specification shall govern.

 

1.3        SUBMITTALS:

 

  1. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

 

  1. Incinerator:

 

  1. Arrangement, description of construction, and outline drawings of incinerator and accessories showing

clearances and dimensions.

 

  1. Predicted performance including burn time based on waste composition specified.

 

  1. Calculation of secondary chamber retention time.