Pet Cremation Incinerator Costs


Product Description

Key Features:  * All models with Dual combustion room.  * High temperature, long lifetime of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 600kgs per hourto 10ton daily.  * PLC Control Plane for Intelligent functioning.  * One year guarantee on incinerator and parts in stock.

Item Specification
Model TS50 PLC
Main Product List per 01 set Primary Combustion Chamber
Secondary Combustion Chamber
Smoke Filter Chamber
Incinerator PLC Control Case
Chimney:5.0Meters
*(upgrade to Stainless Steel, free cost)
Italyoil/gas burner: 02 units
Oil Tank (if oil fuel): 100Liters

Animal Incinerators


Basic Info.

Model NO.:animal incinerator manufacturers
Export Markets:Global

Product Description

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Picture  
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Our Story  Nanjing Clover Medical Technology Co., Ltd..

Incinerator Yd-150


Product Description

Nanjing Clover Medical Technology Co., Ltd..

Model YD-150 
 Burning Rate  150 kgs/hour
Feed Capacity 300 kgs
Paimary Combustion Chamber 1500 Liters
Secondary Combustion Chamber 500 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 1.03Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 17–36 kg/hour
Gas Consumption (Natural Gas) 11–36.7 m3/hour
Internal Dimensions 150 x 100 x 96cm (paimary chamber)
External Dimensions 240 x 170 x 380cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 300 Liters
Door Opening 59 x 81cm
Chimney Length 10.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 7000 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800degree–1000degree
Secondary Chamber Temperature 1000degree-1200degree
Residency Time 2.0 Sec.
Burning Efficiency >98%
Waste Lower Calorific Power 3000Kcal

Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long life. *according to sequence * High temperature, long life of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 500kgs per hourto 6ton daily.  * PLC Control Plane. *according to order  * New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and parts in stock.

Big Scale Medical Waste Incinerator


Product Description

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Picture  
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Nanjing Clover Medical Technology Co., Ltd..

2 combustion chambers type heater



Load Capacity minimum:  1500 kg
Burner fuel type:  Diesel
Burner fuel rate max.:   20-25 Liter diesel/ per hour
Burners minimum: 3
Burning rate minimum: 200-300kg/per hour
Furnace bar area minimum: 2 м3
Fuel tank capacity minimum: 300L
Main chamber burning temperature min. 1100 0C
Afterburner chamber burning temperature min.  1300 0C
Power supply 220V
Incinerator items and electrical appliances should be weather proof
and humidity resistant within the range of 30-90 %
Incinerator should be compliant to the environmental protection rules
in accordance to national legislation
Maximum dimensions – Length – 5m, width – 3.5m, height – 5m.Medical and Biological wastage.
3.1              Main unit
3.1.1
Application      For incineration, general and pathological
3.1.2                                            Capacity       100 – 120 kg/h burn rate
3.1.3
Type    Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit
3.1.4         Operating time                   Minimum 8 hours daily
3.1.5          Operating temperature        From 850 0C to 1200 0C, Automatic controlled
3.1.6          Residual Ash                       5 to 10%
3.2     Primary Chamber
3.2.1
Construction    Constructed from heavy duty mild or aluminized  steel
Or equal and approved equivalent
3.2.2
Insulation material               Refractory material lining similar or equal to calcium
Silicate and hot face combination of heavy duty brickwork
3.2.3
Internal Construction           Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material
3.2.4
Charging Door                      Suitable for manual loading of wastes and with smooth
Dear seal equivalent of Ceramic seals with hinges.
3.2.5          Door Lock                             Automatic, Electric type
3.2.6
Ash removal door       Provided, for removing resultant bottom ash leftovers                              from the Primary chamber
3.2.7                                    Gratings       Provided
3.2.8                                            Loading    Manual loading of waste
3.2.9           Primary Burner                           Fully automatic, with fuel, temperature and speed  controls with ignition system  flame detector                                                         Air fan Complete with safety features, flame failure                                                                    Diesel fired fuel injector type
Flange mounted
3.2.10    Blower      Provided.  3 phase for supplying excess combustion air through the distribution system with speed control system
3.2.11    Temperature    Minimum exit 850 0C
3.2.12                               Observation port    To be provided with protective glass type
3.3    Secondary chamber
3.3.1
Construction    Constructed from heavy duty mild or aluminized steel or equal and approved equivalent
3.3.2                                            Insulation    Refractory material lining
3.3.3             Combustion Temperatures      Above 850 0C, controlled electronically
3.3.4             Gas residue or retention time                                              > 2 second at minimum 850 0C
3.3.5    Secondary Burner    Provided,
Diesel fired,
Fully automatic, with fuel, temperature and speed controls
With ignition system
Flame detector
Air fan
Complete with safety features, flame failure
Diesel fired fuel injector type
Flange mounted
3.3.6    Ejector    Provided, Venturi type, for cooling the flue gases
3.3.7
Combustion Air Fan                      Provided for supplying combustion and creating a
negative drift and turbulences with variable speed control
3.3.8                                         Temperature    Maximum  1600 0C
3.4       Chimney
3.4.1
Construction    Constructed from heavy duty mild or aluminized steel  or equal and approved equivalent
Refractory material lining
3.4.2                                                    Length    10 m above ground
3.4.3                                                        Bore    about 350mm diameter
3.4.4            Discharge temperatures             About 850 0C
3.4.5                                            Emissions    To comply with standards in section 9 of third schedule of the waste management regulations, 2006.
3.5       Electrical System
3.5.1    Control unit                                           Fully automatic with microprocessor based control
unit (PLC) automating all operations of the incinerator
Capable of monitoring all incinerator parameters
With large LCD or similar for display of all progress
Parameters  i.e. temperature of primary and second chambers , turbulence and time
With status lamp
With user of defined and differed programmed operating cycles for different type of loads/conditions
With safety interlocks, display of errors and visible and audio alarms.
System for continuous  emission monitoring
3.5.2    Isolator switch                                  Supply and install isolator switch 100A, 3 phase, 415V, 50Hz, for the incinerator unit , including all necessary cables 10m
3.5.3
Distribution Board           Supply and install distribution board 100 A, 3 phase 415V, 50Hz, complete with MCBs suitable for the rating of the incinerator unit and associated equipment.  Wiring   to be done according IEE regulations.
3.5.4
Wiring       Make provisions for wiring the isolator switch,
Distribution Board control unit to Incinerator and all associated equipment inside to incinerator room.
Working length 20m.
Wiring to be done using PVC Sheath cable on steel conduits and trucking and in accordance with IEE regulations
3.6    Fuel System
3.6.1          Fuel Tank                                            Supply and install storage fuel tank inside the incinerator room at an elevated position (about 1.5 m above the floor)
Tank capacity, 500 liters, constructed from preferable
suitable metallic material or high temperature
resistance material
Fuel type    Diesel
3.6.2
Fuel Lines                                       Supply and install fuel lines, complete with fuel filters, pump, sight glass, fuel level and all other safety devices and connect from fuel tank to incinerator.  Working length , 20m
Fuel pipe material    Special copper pipes or similar and approved materials
4. Physical characteristics
4.1              Main unit                                           Floor mounted, stand alone, fixed hearth type
Dimensions    About 2.5 x 2.8m (WxD)
5.  Operating environment
5.1              Power Requirements                      415V, A/C 50Hz, Three phase, with PE
Ambient temperature                     10 0C to 40 0C
Relatively humidity                          40% to 90%
6             Accessories
6.1             Rack, 2 m long                               1 piece
Waste cart, stainless steel               1 piece
7. Spare parts
7.1                                                      Burner        1 set
7.2              Fuel Filters                                         6 sets
7.3
All other spare parts                 required for replacement during and after 12 months of operations.    2 pieces of each
8              Quality Standards
8.2
Manufacturing standards               Environmental Management and Coordination Act, 1999
Legal Notice No.121 of 29th September 1999 on                                                                         waste Management Regulations
EU waste incinerator Directive- EC 76/2000
BS 3316
WHO Emission Standards
World Bank Emission Standards or any other internationally recognized standards
Conformity to standards                      CE marked or any other internationally recognized documents
9          Local back up service
9.1                                                         Available    Should be available locally
9.2           Capacity to service equipment                                                                         Manufacturer/Agent shall have adequate facilities, spare parts, qualified and skilled technical staff to offer comprehensive maintenance  service and spare parts sales for the lifespan of the incinerator
10       Delivery point
10.1                                                        KEMSA    For inspection and verification
10.2
Moi Voi, Makindu
Maragua, Eldama Ravine and Isiolo Hospitals      For installation, testing, NEMA Certification and commissioning
11    Pre installation works
Provide for foundation plinth, necessary plumbing works, Fuel piping works, Elevated Diesel oil storage tank, electrical works including cabling, trunking and switch gears required to install the incinerator and all its accessories to required IEE standards
12    Installation and testing    Complete installation and setup of the incinerator at designated as per manufacturer’s instructions
Provide fuel and test run the incinerator for 3 hours daily for 7 days
13            Training
13.1
User training                                           On site user training on operation and daily up keep
13.2
Maintenance training                            On-site maintenance training on Preventive Maintenance, repair and trouble shooting
14    Technical Documentations
14.1         User manuals                                          2 sets
14.2         Service manuals                                     2 sets
14.3                                                     Drawings    2 sets
15        Commissioning
15.1    Testing and Commissioning of the machine to the satisfaction of the user
16    Warranty
16.1                                                  Equipment      Minimum of one year after commissioning on all parts.
16.2       Equipment system                                     Nil
17.    Maintenance contract
17.2         Comprehensive preventive & repair         service      Provided a 12 months comprehensive preventive and repair service contract inclusive of spare parts and material from date of commissioning

Capacity per day around 8-10 kg wastage/day.·         Which product do you offer, only incinerator or also compactor, shredder machine, any other equipment related to waste treatment ?

·         For the incinerator, can you propose (and of so please send us specs and price) incinerator for 25 kg/hr, 50 Kg / hr, 100 kg / hr, 200 kg / hr ? what is your minimum and maximum size available ?

·         As we are not so experience in incineration process, can you tell us which type of waste can go into the incinerator and still respecting international environmental regulation ?

·         Do you equipped your incinerator with filters ? if so which one and they are following which standard ?

·         Can you supply exhaust pipe from incinerator to the roof, and then whirly bird to avoid the rain water to go into the pipe ?

·         When we install an incinerator within a building, what are the distance to observe between equipment and wall and roof (as we need to supply also the building to house the incinerator )



Municipal Waste Incinerator


Basic Info.

Model NO.:medical waste incinerator manufacturer
Export Markets:Global

Product Description

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *based on order  * High fever, long life of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 500kgs per hourto 6ton per day.  *based on order  New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and parts in stock.

Items/Model MSW2000 MSW3000 MSW4000 MSW5500
Burning Rate  150 kgs/Hr. 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr.
Feed Capacity  400 kgs 600 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 9500 kgs 13000 kgs 16500 kgs
Picture  
Primary Chamber (Liters) 2000 3000 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270x185x380 280x230x425 320x220x460 360x220x475
Internal Dimensions (cm) 180x115x96 240x120x105 257x147x108 300x147x125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

MUNICIPAL SOLID WASTE INCINERATORS

a specific type to use at a crematorium. Something that allows specifically for ash collection etc.cremation option to the deceased’s family. Is this product suitable, are ashes easily collected etc. a cremator, for pet clinic, could you introduce and all detail of sales, tax, environtment.-Plastic. 500Kg/hr and to be used maximum 6 times, is this means it will provide only 3 tons per day? Noting that project documents requires 10 tons/day
Plastic bottle-
-Rags & oiled
Glass bottles and aluminum-
-Oils
Fat-
Filter, tires, belts
-Chemicals, paint
Household waste-
Municipal incinerators with a 10-metric ton/24-hour capacity, complete with Stacks, control panels and all accessories, complying with 01015 par. 5.16.1
LOT
2.0

Medical incinerator with a 10 kg/hour (15 lbs/hour) capacity shall be constructed on the site, complete with Stacks, control panels and all accessories , complying with 01015 par. 5.16.2
MUNICIPAL SOLID WASTE INCINERATORS

Municipal waste incinerator quantities and capacities shall be designed for 24-hour 7-day-a-week continuous operation.

Incinerators shall be capable of processing both wet and dry material and operating on either diesel fuel, JP-8 fuel,

or waste oil; see Plumbing for fuel storage system requirements. The following shall be provided as a minimum:

Reinforced concrete mounting foundations, feed or charging hoppers (or loaders), primary combustion chambers

with ash cleanout doors, secondary combustion chambers with ash cleanout doors, cyclone air filters (or separators),

and forced air exhaust stacks (or chimneys).

The charging system shall consist of, as a minimum, a hopper for top feeding and mechanically operated hydraulic

charging ram or augur. To prevent warpage or excessive thermal expansion, a charger cooling system using either

air or water shall be provided.

Primary combustion chamber shall be either the rotary- or stationary fixed-hearth (or kiln) type incinerator. Burner

and combustion air controls shall be fully automatic comprising of, as a minimum, electronic ignition and all

necessary interlocks and safety devices to provide safe operation. The chamber and burner shall be designed to

maintain a minimum combustion temperature of at least 700 to 870 C (1300 to 1600 F), but shall not to exceed 980

C (1800 F). The ash-removal system shall consist of the automatic continuous removal of the ash into an ashquench

pit where cooled by water and removed by conveyor.

Secondary combustion chamber shall be either the rotary- or stationary-hearth (or kiln) type incinerator designed to

oxidize (or burn) the organic vapors and gases. Burner and combustion air controls shall be fully automatic

comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to provide safe

operation. The chamber and burner shall be designed to maintain a minimum combustion temperature of at least

930 to 980 C (1700 to 1800 F), but shall not to exceed 1150 C (2100 F). The ash-removal system shall consist of, as

a minimum, the direct manual removal into a dry

Cyclone air filters shall be provided to remove the larger particulates. Cyclone air separators may be provided with

powered fans to increase the velocity of the gases inside the cyclone to improve the collection efficiency for smaller

particles.

5.16.2 MEDICAL WASTE INCINERATORS

Medical waste incinerators shall be specifically designed by the manufacturer to dispose of all medical wastes. All units shall be designed for 8 hours

per day of continuous operation and be rated in quantity per hour (i.e. kg/hr or lbs/hr).

Incinerator loading or charging of medical waste shall be batched-fed manually.

Primary combustion chamber shall be the stationary fixed-hearth (or kiln), multiple-chamber, retort type or larger

capacity rotary-hearth (or kiln) type. Burner and combustion air controls shall be fully automatic comprising of, as a

minimum, electronic ignition and all necessary interlocks and safety devices to provide safe operation. The

chamber and burner shall be designed to maintain a minimum combustion temperature of at least 760 to 870 C

(1400 to 1600 F). The ash-removal system shall consist of the automatic continuous removal of the ash into an ashquench

pit where cooled by water and removed by conveyor.

Secondary combustion chamber shall be a solid-walled and -floored, horizontal, refractory-lined cylinder type

incinerator designed to oxidize (or burn) the organic vapors and gases. Burner and combustion air controls shall be

fully automatic comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to

provide safe operation. The chamber and burner shall be designed to maintain a minimum combustion temperature

of at least 930 to 1200 C (1700 to 2200 F) with a minimum gas residence (or dwell) time of 2.0 seconds. The ashremoval

system shall consist of, as a minimum, the direct manual removal into a dry collection hopper.

Cyclone air filters shall be provided to remove the larger particulates. Cyclone air separators may be provided with

powered fans to increase the velocity of the gases inside the cyclone to improve the collection efficiency for smaller

particles.

5.16.3 INCINERATOR STACKS (OR CHIMNEYS)

Stack size shall be in accordance with the manufacturer’s recommendations. Stacks shall be the forced-air type and

completely self-supporting and unattached to nearby structures. As a minimum, stack heights shall minimize

downwash of stack emissions due to aerodynamic influences from nearby structures and be calculated in accordance

with DoD 4715.05-G, Overseas Environmental Baseline Guidance Document. Stacks shall be provided with

corrosion-resistant steel weather caps.”

Large Scale Municipal Waste Incinerator


Product Description

Waste Incinerator International Market Analytics  Date.

Keyword:  Small incinerators  Medical waste incinerator  Pet animal cremation incinerator  Incinerator makers

Incinerator is a incineration gear, direct fire squander from gas fuel or oi gas. As distinct circumscription, incinerator can be termed many words as under: 

Treatment ability: Small scale incinerator, large scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators  Incinerator gas: Gas incinerator, petroleum incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator manufacturer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.  Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)  Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

Pyrolytic incineration specialized is conventional waste treatment way for many years. All over the world, in many countries, individuals anti incinerator because the incinerator will create a large Dioxin from the smoke. “Dioxins” refers to a set of toxic chemical compounds that share certain chemical structures and biological features. Dioxins can be released to the environment through forest fires, backyard burning of garbage, particular industrial activities, and residue from beyond business burning of waste. Dioxins break down very slowly and previous releasesparts such as incinerators, pet cremation burner, pet cremation burners, pet cremation equipment cost, pet cremations equipment china, pet crematorium + manufacturer china, of dioxins from both man-made and natural resources still exist in the environment. Anyhow, we have to remind that, this is large scale incineration pant, generally more than 30 ton every day. This is a social problem, to analyze and indicate ways in various angles from the general public, government, economic growth, environmental protection, technology advancement, etc. 

So, why people use incinerator?  To begin with, for your medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management.  Secondly, for human body, pet animal, in many countries and regions, we desire to cremation them. This is the service in the process of society growth, and ceremonies to commemorate the disappearance of life. 

As previously two rationale although not just above, we nevertheless utilize incinerators. 

the way you can discover reasonable incinerator for your regional website?  Incinerator is not a cheap equipment, generally the little scale version 's cost around $5, 000USD per unit and large scale version 's cost more than $50, 000USD each unit. Thus, before purchase one unit incinerator, you need to make clear following items: A, burn out what? Incinerator is a incineration gear, function is fire squander. So what kind of waste that you want to cure?  B, little or large? This according to the waste output daily or the waste volume per feed period, like animal dimensions.  Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and also the smoke cleaner than petroleum fuel model. But some neighborhood website don't have gas distribution system.  And other technology items, such as electricity (220V, 380V), waste feed doorway kind, incinerator construction, etc. 

After you clarify these, you can go to discover a local or global producers, asking prices, technical specifications and ultimately buying the right products. 

Items/Model YD-30 YD-50 YD-100 YD-150 Items/Model YD-200 YD-300 YD-500 YD-600 Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 360 900 1200 1500 Primary Chamber (Liters) 2000 2400 4000 5500 Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 200 200 500 500 Secondary Chamber (Liters) 500 1200 1500 1500 Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 200 300 300 500 Oil Tank(Liters) 300 500 500 500 Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 5 5 10 10 Chimney (M) 10 10 14 14 Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES Temperature Monitoring YES YES YES YES Temperature Monitoring YES YES YES YES

Wrote by Nicky