Model Poultry Incinerator


Basic Info.

Export Markets:Global

Product Description

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *based on sequence * High fever, long life of incinerator.  * Free or minimum installation onsite.  * High speed, from 10kgs to 500kgs per hour, up to 6ton per day.  *based on order  * New Design for pet animal cremation business.  * One year guarantee on incinerator and components in stock. 

Application Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation 

Incinerator is a incineration equipment, direct fire squander by gasoline fuel or oi gas. As different circumscription, incinerator could be named many words as under: 

Treatment ability: Small scale incinerator, big scale incinerator and incineration pant. 

Waste substance: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators 

Incinerator gas: Gas incinerator, petroleum incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator producer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer. 

Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 

Burning Speed: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

2 Chamber Medical Waste Incinerator


Product Description

YDC incinerator is newest design for waste treatment, include medical waste, animal cremation and other solid waste. This gear quality structural for kinds of website, such as hospital, environmental department, animal cremation agencies, etc.. Animals squander medical waste china, aravali incinerator of 30 kg per hour capability price, bahrain, pet incinerator, batch incinerator in china, batch load crematory, 

CLOVER Incinerator provide updated versions with dual combustion chamber, mix combustion chamber and smoke filter chamber using refractory lines, and the combustion chamber temperature up to 1200 deg C.

Items Specification
YDC Model YD-10C / YD-20C / YD-30C / YD-50C
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Process Engineering Design of Pathological Waste Incinerator


Basic Info.

Model NO.:small medical waste incinerator manufacturers
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste can utilize within this equipment?  A: This equipment for medical waste, pet creature, Municipal waste, live squander. Prohibit any explosive and radiation substance, liquid waste and gas waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Treatment capacity  A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t mean any waste material. The animal/pet combustion rate around 2/3 of average power. 

Clover incinerator utilize time per day up to 24 hours. Between every feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding squander. Actual combustion time per day is about 16 hours. The lifetime of incinerator involving 5-10 year based on usage. 

Ordinarily, we proposition small laboratory, small clinic use capability under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output capacity around 2kgs per people every day. If there are 200 sickbed at the clinic, that's mean you need one incinerator capability around 400kgs per day, change to power per hour is around 30-40 kgs per hour. According the performance time every day, waste material, funding, development, etc, you can use capacity from 30-50 kgs each hour incinerator.  *How to compute Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Assembly and Testing  A: We supply all files and incinerators easy to setup and functionality. Customer can send people visit our factory to learn operation and installation. Generally, We do not send engineer to local site if not request. The dispatch price is extra based on order. 

Q: Combustion Temperature  A: The very first combustion chamber: 800-1000 centi level.  The next combustion chamber: 1000-1200 centi level.  PLC mode based on model and order. 

Q: Operation and maintenance costs  A: Operation price based on fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according version, utilize situation. 

One person can service 02 unit incinerators. Medical waste diesel incinerator, medical waste incinerators, mobile incinerator china, nanjing clover medical technology co., ltd., pet crematorium equipment, The staff must have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on functionality consumer guider, and understand risk of medical waste to safeguard worker self with necessary protection component. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Small Scale Incinerator 10kgs Feb Hour


Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

Essential Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long lifetime. *based on sequence * High fever, long lifetime of incinerator.  * Free or minimal installation onsite.  * High burn rate, from 10kgs to 500kgs per hourto 6ton per day.  * PLC Control Plane. *based on order  * New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock.

Items Specification
YDC Model YD-10C / YD-20C / YD-30C / YD-50C
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Solid Waste Incineration


Product Description

Incinerator is a incineration gear, direct fire waste by gasoline fuel or oi gas. As different circumscription, incinerator can be termed many words as below: 

Therapy ability: Small scale incinerator, big scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators  Incinerator gas: Gas incinerator, oil incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator manufacturer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.  Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)  Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

YDC incinerator is newest design for waste treatment, include health care waste, animal cremation and other solid waste. This gear quality structural for kinds of site, such as incinerators for animal waste sweden, incinerators for hospital wastes, incinerators for pets purchase, incinerators for poultry out of china, incinerators available kenya, hospital, environmental division, animal cremation bureaus, etc.. CLOVER Incinerator provide updated versions with dual combustion chamber, mix combustion chamber and smoke filter chamber using refractory lines, and the combustion chamber temperature up to 1200 deg C.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Municipal Waste Incinerator


Basic Info.

Model NO.:medical waste incinerator manufacturer
Export Markets:Global

Product Description

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *based on order  * High fever, long life of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 500kgs per hourto 6ton per day.  *based on order  New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and parts in stock.

Items/Model MSW2000 MSW3000 MSW4000 MSW5500
Burning Rate  150 kgs/Hr. 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr.
Feed Capacity  400 kgs 600 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 9500 kgs 13000 kgs 16500 kgs
Picture  
Primary Chamber (Liters) 2000 3000 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270x185x380 280x230x425 320x220x460 360x220x475
Internal Dimensions (cm) 180x115x96 240x120x105 257x147x108 300x147x125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Clover Medical Limited a Top Waste Incinerator


Basic Info.

Model NO.:construction of an incinerator
Export Markets:Global

Product Description

Incinerator is a incineration gear, direct fire squander by gasoline fuel or oi gas. As distinct circumscription, incinerator could be termed many words as below: 

Treatment ability: Small scale incinerator, large scale incinerator and incineration pant. 

Waste substance: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators 

Incinerator gas: Gas incinerator, oil incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator producer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer. 

Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 

Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES