Incinerator


Basic Info.

Model NO.:30 kg per hour
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Items/Model TS30(PLC)
Burn Rate 30 kg/hour
Feed Capacity 60kg
Control Mode PLC
Combustion Chamber 330L
Internal Dimensions 75x75x60cm
Secondary Chamber 180L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.5Kw
Oil Consumption (kg/hour) 10.2–20
Gas Consumption (m3/hour) 9.8–20
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 55x50cm
Chimney 5Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800 degree –1000 degree
2nd. Chamber Temperature 1000 degree –1200 degree
Residency Time 2.0 Sec.
Gross Weight 3000kg
External Dimensions 175x120x140cm

Principle of the Incinerator Gear is incineration/combustion/burn.

three chamber system incinerator

The primary factors considered in the design and construction of a modified De-Montfort type intermittent incinerator for combusting medical wastes were the waste types, fuel, chimney size, and flue gas residence time. The design analysis was based on flue gas flow rate of 0.13 m3/s, maximum primary chamber temperature of 870 °C and minimum ambient temperature of 27 °C. The total flue gas residence time of 6.9 s was achieved for the three chamber system of 0.9 m3 total volume. The medical wastes generated from the four medical facilities in Ga East District (Ghana) consisted of infectious sharp objects, syringes, wound dressings and gloves; which were incinerated at a throughput of 80 kg/day with destruction efficiency of 98.47 %, using fuelwood as primary fuel. The natural convection thermo-fluid flow was controlled by ambient wind speed of ~ 3.8 ms-1, at temperature of 31.5 °C. The primary combustion chamber temperature attained was ~ 516 °C, while the third chamber temperature reached 760 °C, which ensured complete combustion of the wastes with reduced particulate matter emissions. At optimum operating capacity of 0.6 m3, up to 4 cycles of incineration were done in a day, each cycle lasting about 80 minutes.

3 Burning Chambers MEDICAL WASTE BURNER


Variation

WS-35

Picture

Burning Price

Typical 35 kgs/hour

Feed Capacity

Regular 80 kgs

Main Burning Chamber

460 Liters

Additional Burning Chamber

200 Litres

3rd Burning Chamber

200 Litres

Smoke Filter Chamber

Damp Scrubber System

Feed Mode

Guidebook

Voltage

220V

Power

2Kw

Gas Type

All-natural Gas/LPG

Heating System

Italy Original

Oil Intake (Diesel Oil)

***

Gas Consumption (Natural gas )

Normal 24 m3n/hour

Internal Dimensions

110 x 70 x 60cm (trick chamber)

Outside Measurements

160 x 100 x 180cm (without moist scrubber)

Temperature Display

Yes

Oil Storage Tank Ability( if petroleum gas)

***

Door Opening

50 x 50cm

Smokeshaft Dimension

5.0 Meters

Smokeshaft Kind

Stainless-steel

Equipment Gross Weight

5000 kgs

Procedure Technical Specs

Secret Chamber Temperature Level

800 ℃–– – – -1000 ℃

Added Chamber Temperature Degree

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Effectiveness

> 98 percent

Waste Lower Calorific Power

Primary chamber:
Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature 

sensor points with complete internal fans.
Secondary Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 

02 Sec gas residence times.
Third Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal 

fans. 02 Sec gas residence time.

HICLOVER – Medical Environmental 

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-25


Clover Incinerator update Social media site, including facebook,twitter,linkedin

we now publish mutil-social media for incinerator online marketing, this will be helpful our marketing and customer relationship.

 

http://www.facebook.com/hiclover

https://twitter.com/hiclovercom

https://www.linkedin.com/in/hiclover

https://plus.google.com/+IncineratorClover

https://www.youtube.com/c/IncineratorClover

https://www.pinterest.com/incinerators

http://cloverincinerator.blogspot.com/

http://cloverincinerator.tumblr.com/

http://vk.com/hiclover

https://www.instapaper.com/p/incinerator

https://www.flickr.com/photos/clover-incinerator/

 

 

 

red bag waste incinerator


“Waste chamber

Chamber capacity 300 kg

Chamber volume .54m3

Chamber size (outside) Width: 91cm, Height: 86cm Length:

152cm

Door opening 66 x 76 cm

Height to door 84 cm

Height to top of stack 5.4 m

Suggested slab size (L x W x Thickness) 1.8

m x 2.4 m x 10 cm

Burn rate: Approximately 45 kg/hr.

Stack:

2′-14″” dia. (36 cm), 14 gauge (1.90 mm) aluminized steel,

refractory lined

8′-12″” dia. (30.5 cm), 16 gauge (1.52″

“Burners Diesel

Operation Manual timer

Electrical service Standard – 115 volt, 60 HZ, 20 amp

General Description:

Primary

Chamber: Heavy-duty steel casing

High quality refractory lining and insulation

Large full size top load door and liquid

retention sill

1 x diesel oil fired ignition burners operated on/off

Ash removal door

Chimney: Heavy-duty stainless steel

casing

1.5m length

0.6m refractory lined stack

Control Panel: Control of 1 burner

Timer control 0-12 hours

Integral fan

timer control

Temperature monitoring

Automatic Control

Cycle time set up

Ancillaries: Operating and maintenance manuals

Spares list

Ash Rake

Containerization: 20 foot shipping container with incinerator fitted

500 litre fuel tank”


Kenya Incinerator Solutions for Hospitals and Humanitarian Camps with HICLOVER

Kenya Incinerator Solutions for Hospitals and Humanitarian Camps with HICLOVER

The growing healthcare sector in Kenya has highlighted the urgent need for reliable medical waste management solutions. Hospitals and clinics across Nairobi, Mombasa, and county-level facilities must handle infectious sharps, contaminated gauze, pharmaceutical residues, and pathological waste safely and sustainably. In this context, the demand for a Kenya incinerator for hospital medical waste disposal has expanded rapidly, driven by both national regulations and donor-funded programs.

Hospital Applications with Refractory Lining

One of the key requirements for Kenyan hospitals is durability and safety under continuous high-temperature operation. Modern medical waste units from HICLOVER are built with high alumina refractory lining (65% Al₂O₃), designed to withstand up to 1750 °C. A well-constructed incinerator with refractory lining for Kenya hospitals ensures:

  • Long service life of the combustion chambers.

  • Consistent burn temperature in the range of 850–1200 °C.

  • Reduced fuel consumption thanks to high thermal retention.

  • Protection against thermal stress in high-throughput operations.

This is particularly vital for county referral hospitals, which generate large volumes of waste daily and require equipment that can operate reliably with minimal downtime.

HICLOVER TS150 PLC – A Reliable Model for Kenya

The HICLOVER TS150 PLC model, rated at 150 kg/hour, is an ideal fit for Kenya’s medium-to-large hospitals. It combines containerized mobility with advanced automation, including:

  • PLC automatic control system with optional manual override.

  • Dual combustion chambers, ensuring a minimum of 2 seconds retention time in the secondary chamber.

  • Automatic ignition with flame stabilization, reducing operator workload.

  • Corundum probe thermometers rated up to 1600 °C for accurate monitoring.

  • Optional wet scrubber to achieve compliance with NEMA and WHO emission standards.

Containerized construction allows the system to be installed without civil engineering works, making it suitable for both urban hospitals and rural county facilities.

Humanitarian Camps and Riello Burner Technology

Kenya hosts numerous UN agencies and NGO operations that support neighboring regions like Somalia and South Sudan. These humanitarian camps generate a diverse waste stream, from medical sharps to general solid waste, requiring robust disposal systems. The incinerator with Riello burner for humanitarian camps in Kenya provides dependable ignition, stable flame, and high combustion efficiency.

Riello G-series burners, widely used in HICLOVER systems, offer:

  • Low fuel consumption for diesel-fired operation.

  • Reliable ignition cycles, even in harsh field conditions.

  • Easy maintenance with available nozzle and electrode kits.

This technology ensures that humanitarian and peacekeeping camps can maintain environmental compliance while minimizing operational challenges.

Containerized and Mobile Advantages

For both hospitals and humanitarian projects, mobility is a decisive factor. HICLOVER’s containerized mobile incinerators are built into ISO containers or trailer-mounted designs, offering:

  • Rapid deployment in emergency response or refugee camp settings.

  • Weatherproof housing suitable for East African conditions.

  • Secure, fire-resistant construction with integrated chimneys.

  • Compatibility with dual-fuel operation (diesel and gas).

This mobility ensures that waste treatment capacity can be relocated as projects shift, a key requirement for NGOs and UN agencies operating across Kenya’s borders.

Conclusion

Kenya’s healthcare facilities and humanitarian operations demand high-quality incineration systems that combine durability, efficiency, and mobility. From a Kenya incinerator for hospital medical waste disposal to an incinerator with refractory lining for Kenya hospitals, and even an incinerator with Riello burner for humanitarian camps in Kenya, HICLOVER provides tailored solutions to match local needs. With models like the TS150 PLC and optional wet scrubber systems, HICLOVER supports Kenya’s commitment to safe, sustainable, and compliant waste management.

For inquiries:
Website: www.hiclover.com
Email: sales@hiclover.com
Mobile (WhatsApp): +86-13813931455

Mobile: +86-13813931455(WhatsApp)

Email:     sales@hiclover.com     
Email:     hicloversales@gmail.com 

 

2025-09-03/13:40:53

Incinerators at 3 facilities to refine medical care waste


a. 2.5 metric heaps daily health care waste burner

b. 1.5 metric heaps daily healthcare waste burner

c. 300 kg daily medical care waste burner

Our favored technology is double-chamber incineration, but if you propose a different modern technology, that is okay.

We request information on the following for every of the above demands:

1. Capital cost (provided expense in Oman)

2. Operation as well as upkeep expenses (yearly )

3. Number of motorists called for

4. Item specs (sizes, temperature levels, home time, cycle time )

5. Various other auxiliary equipment That’s needed or recommended by you


Small Scale Incinerator for Solid Waste


Basic Info.

Model NO.:smokeless crematorium
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Items Specification
Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC)
Main Product List Double Combustion Chamber
Smoke Filter Chamber
PLC Mode Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)