Pre-assembled containerized type waste incinerator


Pre-assembled, containerized type

 Burning rate: 100 – 120kg / hour medical waste incinerator
 Minimum operating temperature: 8500c
  (Primary combustion)
Maximum operating temperature: 14500c  (afterburner chamber)
Secondary Burning capacity: Compulsory.
Density insulation: 20 mm high hospital waste incinerators
Refractory casting: minimum 65mm
Heavy duty refracting lining to withstand 15000c
Average burn out time: maximum 3.0 hrs
Fuel type: fuel oil (diesel) cannabis waste management
Fuel consumption in L/hr: 7.5 to 9
Residency time in secondary chamber: 2 secs.
Residue ash post 100kg Max 3.8 kg
Installation period Maximum 7days.

HICLOVER Solution for Fighting COVID-19, with ISO9001:2015/CE(2006/42/EC,2014/30/EU) Certification.
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)

Three Combustion Chambers(Optional)

2. Auto Roll Air Filter for Clean Room(Air Purification)

3 Ranked for high risk waste

Pet Cremation Equipment

Nanjing Clover Medical Technology Co.,Ltd.
Tel:  +86-25-8461 0201    

For Pet(small/big) Cremation Business

Mobile: +86-138139 31455
WhatsApp: 008613813931455
WhatsApp: 008615380948599
Twitter ID: @hiclovercom
Wechat: 008613813931455 (ID: hiclovercom)
Wechat: +8615380948599 (ID: wasteincinerator)

Animal Incineration Equipment

For additional animal incineration

Website1: www.hiclover.com 
Email1:     [email protected]
Email2:    [email protected]    
Email3:   [email protected]  

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Typical )

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Brand HICLOVER HICLOVER HICLOVER HICLOVER
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg
Control Mode PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm
Chimney 3Meter 3Meter 5Meter 5Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm

PLC Auto.


PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

2021-03-02

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

CE and ISO Certification Pass Incinerators

 

2021-03-02


Burner to reduce black bag garbage dump waste


30 August 2013 Last upgraded at 21:18 BST

Five councils in south eastern Wales have developed a partnership to take care of black bag waste in a proposal to minimize rubbish going to garbage dump.

Write-up valued quote from the network QQ图片20160218145327

Environment contributor Iolo ap Dafydd reports.

Article priced quote from the network QQ图片20160218145327


20 Kgs Capacity Medical Incinerator


Product Description

Key Features:  * All models with Dual combustion room.  *according to sequence * High temperature, long lifetime of incinerator.  * Free or minimum installation onsite.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.  *according to order  New Design for pet animal cremation enterprise.  * One year warranty on incinerator and components in stock. 

Nanjing Clover Medical Technology Co., Ltd.. Is a top waste incinerator manufacturer in China. We’re local producer and among the greatest exporter of China. Pyrolytic incinerator gear technical is main waste treatment each one of the world, for Medical Waste, Animal Incineration, home waste incinerator in china, hospital burner manufacturere, hospital diesel fuel fired incinerators, hospital gear burner 100kg per day, hospital incinerater, Pet cremation and other good wste. The potential from 10kgs/Hr. To 500kgs/Hr. Up to 6ton per day. Presently, we provide different series for local customer requirements and layout updated incinerator with our top technology. The updated design characteristic of our assortment of incinerators make them among the most cost effective in the world.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Heater YD-100 for Iraq



There are 03 sets Design YD-100 circulation to Iraq between year 2013 to 2014. The heater use for neighborhood a number of structure as well as construction sites in addition to all gas kind is diesel oil.

Items/Model YD-100
Burning Rate (kgs/Hour) 100 kgs/Hr.
Feed Capacity (kgs) 200 kgs
Equipment Weight 5300 kgs
Primary Chamber (Liters) 1200
Secondary Chamber (Liters) 500
External Dimensions (cm) 220x180x360
Internal Dimensions (cm) 130x100x90
Oil Tank(Liters) 300
Door Opening (cm) 55 x 80
Chimney (M) 10
Chimney Type Stainless Steel
Secondary Chamber  YES
Mix-Combustion Chamber YES
Smoke Filter Chamber YES
Combustion Fuel Oil/Gas
Residency Time 2.0 Sec.
Temperature Monitoring YES
1st. Chmaber Temperature 800–1000
2nd. Chmaber Temperature 1000-1200
Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.



waste incinerator manufacturer china


waste incinerator manufacturer china

The incinerator burn waste in primary combustion chamber and burn off the smoke from primary combustion room again to make sure environmentally friendly with no smoke, smelless, decrease pathogenic bacteria disease. System solutions for medical waste ecological, such as waste incineration, smoke cessation treatment, high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc..

incinerator manufacturers


2.1 General Description

The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The controlled sections may contain but not Limited to:
B) Ensure secondary air supply is controlled.
D) Ensure that the gas temperature measured against the inside wall in the secondary chamber and not in the fire zone is not less than 1100 degrees centigrade.
3. Assessment and preparation and construction of a normal incinerator drop with one waste storage space ( see the design )

4. Provision of operation and maintenance manuals and drawings complete with maintenance program and instructions. Fuel oil storage tank- Mild steel1500 liters capacity

6. Onsite training for operation and maintenance employees.

IMPORTANT
9. Ought to have a complete width counterbalance loading door allowing easy access to the main chamber for loading and removing ash.
E) A strong particulate meter/recorder should be provided.
F) Ensure both primary and secondary combustion temperatures are maintained until all waste is totally combusted. The particulate collectors may comprise any of the following or a combination thereof:
6. The stack/chimney.
O) The purpose for measurement of emissions will be provided.

2.7 Instrumentation

a) Instrument for determining the interior wall temperature and not burner flame temperature must be provided for both primary and secondary chambers.
2.3 Main Combustion Chamber.

a) This chamber should be outfitted with burners using low sulphur gas.
B) An audible and visible alarm must be set up to warn the operator once the secondary chamber temperature falls to below the specified temperature.
M ) The chimney should be visible to the operator from the feeding place.
E) All the emission to the atmosphere aside from steam or water vapour must be odourless and totally free of mist, fume and droplets.
B) The chamber should ensure a minimal exit temperature of 850 degrees centigrade.
D) Opacity of this smoke shouldn’t exceed 20% seen by 50 yards with naked eyes.
2. Feed chamber/charging
2. Provision for adherence to OSHA and other statutory requirement relating to Health and Safety of employees during execution of the works covered in this tender.
F) Any other instrument which may be considered necessary.

2.9 Emission Limits

a) Combustion efficiency (C.E) shall be 99.00percent at which C.E =%Carbon dioxide x 100 / [% Carbon dioxide + carbon dioxide ]
b) Electrostatic precipitators
1. Overall plant layout
Capacity/island: 4000 kg/day; 25000 kg/day; 31000 kg/day; 48000 kg/day

Burning temperature — more than 12000C

Two chambers — minimal

Emissions — dioxin and heavy metaly — better afterward Kyoto protocol

Emission — tracking method

Waste unloiding — straight from squander monitor to incinerator

d) A smoke density meter/recorder should be provided.
5.
C ) The secondary chamber gas residence time will probably be 1 second at 1050 +/- 50 degrees centigrade with 3% oxygen in the stack gas.
7. Minimum capacity of primary chamber = 0.18 cubic metres
a) Cyclone separator
Supply, Installation and Commissioning of An Incinerator in Eastern Hydros [ Page 28

2.2 Feeding and Fixing
3. Main combustion chamber
C ) Ensure residence time is not less than two seconds.
4. Particulate scrubbers
Controlled hygienic mechanical feeding that does not negatively influence the atmosphere temperature in the primary and secondary chambers of the incinerator will be used.
G) The average dioxin and furan concentration in the emission should not exceed 80mg/m3 total dioxins and furans if quantified for an interval of 6 to 16 hours.

– Manual technical monitoring is shipped with the hardware together with explanations of failures and settlements
8. Burn speed (speed of waste incineration) = at least 20 kg each hour
1.
C ) Fabric filters
2.6 Chimney/Stack

l) The chimney should have a minimum height of 10 metres above ground level and clear the maximum point of the building by not less than 3 metres for all roofs. The topography and height of adjacent buildings within 50 metres radius should be taken into account.
E) Ensure the emitted oxygen content of the emitted gases is not less than 11%
N ) The minimum exit rate should be 10 metres per second and at least two times the encompassing wind speed (Efflux velocity = wind speed x 2) whichever is higher to ensure no down washing of leaving gases.

1.

Burning temperature – over 12000C

Two chambers – minimum

Emissions – dioxin and heavy metaly – better then Kyoto protocol

Emission – monitoring system

Waste unloiding – directly from waste track to incinerator


Large Scale Municipal Waste Incinerator


Basic Info.

Type:Incinerator
Export Markets:Global

Product Description

Key Attributes:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to sequence * High fever, long life of incinerator.  * Free or minimum installation onsite.  * High speed, from biology waste 2b waste burner, biomedical incinerator available, biomedical waste china, biomedical waste incinerator manufacturers in china, brainwaves systems center east, 10kgs to 500kgs per hourto 6ton daily.  *according to order  New Design for pet animal cremation enterprise.  * One year warranty on incinerator and parts in stock.  Application Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES