Demands and specs to the practice of supply, installation, performance and ensure the three incinerators for burning and incineration of medications as well as harmful chemicals for customizeds branch
Free 3 years guarantee for incinerators from shipment day. In addition of complimentary extra components guarantee letter needs to be valid for 10 years from the end of assurance.
– All doors must possess unique lock aren’t permitted non-persons delegated to operate.
– The iron fencing has to have a 5 meters Width entrance.
Send your manuals for installation systems.
Please provide details to your complying with,.
Electric apparatus should be delivered with support guidebook in English
Send out a person to fix as well as educate our employees for 5 individuals in each area.
Supplies operating as well as emergency scenario maintenance also provides totally free spare parts for 3 in the starting day of the project. The company should make routine upkeep every 3 weeks as well as increase the upkeep report to the administration of public problem and also Care.
– Guarantee that the combustion of materials released from the secondary room has to be at least 2 seconds length as well as the space is lined with high-density ceramic fibbers.
3- Brochures of stove with all the called for specs
The offer cost has to include the following;-.
– heating systems should have certificates are encouraged worldwide ventures and authorities competent for environmental security In the nation of origin or the General Presidency of Meteorology as well as Setting Protection from Saudi Arabia.
– Must have a automatic ignition and petrol is use.
– The floor finishing should be high-quality epoxy paint.
5- Train 5 people for 2 days for each device for a length of 2 days for installation, functionality, and security. Supply certificates.
– The method of feeding the furnace using a side slot or from the top and also the exhaust of the smoke is entirely stopped.
– Incinerators have to have smokeshaft not much less than “4 meters” height in the surface of the oven, also, it ought to be thermally protected and also non-rust able, as well as need to similarly be removable, installment as well as tide default.
– a heating system has the capacity to hold up against acute temperatures as much as “130o c in addition to also, it guarantees continuous procedure of which may be used for 1 day with the capacity to eliminate residues throughout the job of the stove, Protecting coating of calcium have to be present from the chambers with Density not less than 50 mm as well as a wall depth of 100 mm.
The business must make all of the maintenance work also adjustment of the control and defense tools and also filters/ filters detoxify insulation.
Area temperature level sensors.
Files must include all of the information such as pamphlets, technical resources, operating, maintenance guidebooks, as well as pamphlets handling the key-board.
1-Technical explanation includes technological specifications, scope of project, the needs of the process and upkeep.
Two initial costs.
– Automatic anti-rust as well as heat electrical circuit ought to be provided.
– The stove can benefit 24 hr so regarding permit for the burning of materials for a period of not much less than 12 successive hours and the remainder for air conditioning and gives full gas container using a capacity of 1000 L to turn on the oven.
3- Provide certification that the incinerators are environmentally friendly and attach evidence that environmental management businesses in the nation of Origin and also your product must be discharges cost-free as a consequence of the amount of sensitivity of its own worldwide atmosphere vents.
– The remainder of the accessories in most of the tendencies even makes it possible for the employee right feeding as well as maintenance job, cleansing and relocate handily thinking about the propensities of the base to the door for water drainage of water.
– a heating system Have to get two spaces, one of them is the main space of not much less compared to “5” ranges to the practice of burning materials and several other secondary region of not much less “2” ovens to shed resulting gas in the first process as well as the smokeshaft.
– Incinerators have to be fitted with a control board of the digital tricks to monitor all the vital indicators of activation tricks, as well as start-up and switch off so as to be separated inside a steel box together with the existence of the following:.
– Burners must possess the capacity of self-cooling after conclusion of the daily operating period.
– The dimensions of the base are increased by (2 meters) in the medial side of burners.
GARANTEE.
Validity of deal ought to be not less than 6 weeks
– All devices should be very immune to outside conditions like high temperature (50oc).
1. Asking for professionals and drivers for a period not less than two times at each website and give trainees training certifications.
In situation of sequence, we need two certificates of origin That Has to be stamped from Saudi consular office on your nation
– The heating systems are very effective, emissions-free, risk-free, and environmentally friendly as well as have capacity of not less than 3,000 kg of materials as well as the purchase price of melting at 400 kg/ h.
Two – Technical explanation for support technicians training and heater drivers.
– Isolation of shedding region: the place between the walls must be of those “stainless-steel”. Furthermore, shed space must complete of Thermal insulation merchandise.
Timer for Extinguish the stove instantly depending on the moment called for.
Provided moment asap
Alarm system Sensor at the event of (mishaps “heater” or filtration apparatus or heating leakage or interior connections as well as electric wiring).
Indicators for furnaces as well as index overload.
Screens for the warmth level of those rooms.
Aerosols Filter signals / monitors.
– Mount anti-rust and hot Umbrella of brick and also steel (pyramid form) of (5) meters altitude above the ground which setup using the border of the concrete base by columns that are thick .
– Supplying fire extinguisher for each website having an capability of 10 kg at least