Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste can utilize within this equipment? A: This equipment for medical waste, pet creature, Municipal waste, live squander. Prohibit any explosive and radiation substance, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t mean any waste material. The animal/pet combustion rate around 2/3 of average power.
Clover incinerator utilize time per day up to 24 hours. Between every feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding squander. Actual combustion time per day is about 16 hours. The lifetime of incinerator involving 5-10 year based on usage.
Ordinarily, we proposition small laboratory, small clinic use capability under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output capacity around 2kgs per people every day. If there are 200 sickbed at the clinic, that's mean you need one incinerator capability around 400kgs per day, change to power per hour is around 30-40 kgs per hour. According the performance time every day, waste material, funding, development, etc, you can use capacity from 30-50 kgs each hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Assembly and Testing A: We supply all files and incinerators easy to setup and functionality. Customer can send people visit our factory to learn operation and installation. Generally, We do not send engineer to local site if not request. The dispatch price is extra based on order.
Q: Combustion Temperature A: The very first combustion chamber: 800-1000 centi level. The next combustion chamber: 1000-1200 centi level. PLC mode based on model and order.
Q: Operation and maintenance costs A: Operation price based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according version, utilize situation.
One person can service 02 unit incinerators. Medical waste diesel incinerator, medical waste incinerators, mobile incinerator china, nanjing clover medical technology co., ltd., pet crematorium equipment, The staff must have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on functionality consumer guider, and understand risk of medical waste to safeguard worker self with necessary protection component.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |