Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Incinerators – 2
Basic Info.
Additional Info.
Product Description
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
2nd. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
PLC Incinerator (TS50 PLC)
Basic Info.
Additional Info.
Product Description
Items/Model | TS50(PLC) |
Burn Rate | 50 kg/hour |
Feed Capacity | 100kg |
Control Mode | PLC |
Combustion Chamber | 560L |
Internal Dimensions | 100x80x70cm |
Secondary Chamber | 280L |
Smoke Filter Chamber | Yes |
Feed Mode | Manual |
Voltage | 220V |
Power | 0.7Kw |
Oil Consumption (kg/hour) | 12.1–24 |
Gas Consumption (m3/hour) | 9.9–26.1 |
Temperature Monitor | Yes |
Temperature Protection | Yes |
Oil Tank | 100L |
Feed Door | 70x55cm |
Chimney | 5Meter |
Chimney Type | Stainless Steel |
1st. Chamber Temperature | 800–1000 degree |
2nd. Chamber Temperature | 1000-1200 degree |
Residency Time | 2.0 Sec. |
Gross Weight | 4500kg |
External Dimensions | 230x130x155cm |
medical waste diesel incinerator
medical waste diesel incinerator Burning Rate:47.5–50kg/hour
Minimum Operating Temperature:850o C(primary combustion)
Maximum Operating Temperature:1450 oC(Afterburner chamber)
Secondary Burning Capacity:Compulsory
Density Insulation:20mm High
Refractory Casting:Minimum 65mm
Heavy duty refracting lining to withstand:1500 oC
Average burn out time :maximum:3 hrs
Fuel type:Diesel
Fuel Consumption in L/hr:7.5 to 9
Residence time in secondary chamber:2sec
Residue ash post 100kg:Max 3.8kg
Device for preventing infectious spatter and/or cross-contamination by safely sterilizing needles, rings, etc. by infrared heat.
Electrical characteristics
1) A 120V, 60Hz mono-phase electrical source with line connection plug NEMA 5-15 type.
2) Protections against over-voltage and over-current line conditions.
3) Compliance with applicable Haitian standards and regulations.
Operational characteristics
4) Fast complete sterilization in around 5-7 s.
5) Fully isolated quartz/ceramic tube, to grant safety for the user (no open flame).
6) Working temperature around 820°C.
7) Mounted on a stable base, as per example below.
waste incinerator manufacturers china
5-1- Chambre de post combustion est installée au dessus du foyer de combustion , elle est constituée d’un
cylindre métallique revêtu intérieurement d’une couche d’ isolant et d’une couche de matériaux réfractaires.
5-2- Volume intérieur?: 2,1 m3
Est dimensionnée pour pouvoir garantir un temps de fumée de 2 secondes à 1100°C avec un pourcentage d’oxygène libre
d’au moins 6 %.
5-3 -Accessoires
?Trappe de visite boulonnée frontal pour permettre l’inspection périodique
?La liaison à la chambre de combustion est tapissée de réfractaire
?Installation les br?leurs
?Installation des sondes de mesure température
- PRODUCTION DE L’AIR COMBURANT DE LA CHAMBRE DE POST COMBUSTION
?Ventilateur centrifuge
?Tuyauteries de distribution d’air
?Série de vannes de distribution d’air
?Soupape de régulation de l’air soufflé asservi par la sonde du débit d’ oxygène
- BRULEUR DE LA CHAMBRE DE POST COMBUSTION
Sont prévus 2 br?leurs du type à l’air soufflé au gasoil équipés des dispositifs de sécurité.
A la mise en route du four les deux br?leurs sont allumés pour assurer la température minimale d’au moins 1100°C?;
ils restent en marche successivement pour maintenir la température constante.
Puissance thermique installée (290 + 350) KW.
- CHEMINEE D’EVACUATION
Constitué par un conduit métallique vertical de 8 m de long installée au-dessus de la chambre de PC, diamètre 630 mm
en t?le d’acier au carbone avec garnissage intérieur en réfractaire
- ARMOIRE ELECTRIQUE DE COMMANDE ET REGULATION
Composée de?:
?Circuit 380 V- 50 HZ-3 phases
?Voyant sous tension
?Commande d’arrêt général
?Voyant état des bruleurs
?Affichage des températures des deux chambres
?Minuterie des temps des cycles.
?Une variation des vitesses des ventilateurs
?Le tableau et les cablages sont prévus aux règles CEI avec protection IP 55
?Microprocesseur pour le contr?le et la régulation des températures, ainsi que les cycles d’opération
?Cablages réalisés selon les règles CEI.
- INSTRUMENTATION DE CONTROLE ET DE MESURAGE CONTINU
Les dispositifs suivants sont prévus?:
1)Thermocouples pour la mesure de la température en chambre de combustion? et postcombustion, à la sortie de
l’échangeur dans la section d’entrée du filtre
2)Système de mesure de la concentration d’oxygène dans les fumées humides a la sortie de la chambre de postcombustion
constitué de?:
?Sonde de mesure de l’oxygène à l’oxyde de zirconium
?Pompe à la membrane
?débitmètre
An Incinerator is to be supplied by the Contractor on a rental basis at a location established by the Company. The
Contractor is to provide trained and competent personnel with initial installation, commissioning and operational
training under the supervision of the manufacturer’s technician. The incinerator is to be maintained and operated to
manufacturer’s specifications by trained personnel. Contractor must have sufficient personnel trained and competent to
operate the incinerator throughout the contract period. Specifications for the incinerator are attached in Appendix A.
incineration Furnace for burning patalogical
incineration Furnace for burning patalogical ( such as human tissue or blood ) as west
The weight of this west materials is 700 kg per month and we need an isolated furnace
Without fume and any harmful gas
. INCINERATOR SPECIFICATION
# Description Specification
1 Burning Capacity – 400 kg/time and should not be less than 300 kg/time. Maximum combustion time must be 6 times/day
2 Chimney external diameter – 300 to 400 mm
3 Fan power – Must not exceed 1.1kw
4 Voltage – 220V
5 Oil consumption – Must not exceed 14kg/h
6 Feeding door diagonal dimension (mm) – Not less than 500mm
7 Incineration Temp. (⁰C) – 800 or above
8 Emission
CO – Must not exceed 100 mg/m3
SO2 – Must not exceed 400 mg/m3
HF – (Hydrogen fluoride) Must not exceed 9.0 mg/m3
NO2 – Must not exceed 500 mg/m3
Smoke dust – Must not exceed 100 mg/m3
9 Height of the Incinerator – Not less than 10m above ground level
10 Manufacturer’s Warranty – Not less than 1 year
11 Electrical Connection – From nearest distribution box using 25mm2 electrical cable and all related connections and wiring