Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

incinerator manufacturers china


  1. Ash should be only 5% of the waste material

 

  1. Weight of Incinerator – 50-60 Kg

Municipal incinerators with a 10-metric ton/24-hour capacity, complete with Stacks, control panels and all accessories,

complying with 01015 par. 5.16.1

LOT

2.0

 

Medical incinerator with a 10 kg/hour (15 lbs/hour) capacity shall be constructed on the site, complete with Stacks,

control panels and all accessories

 

 

  1. 220V AC

 

  1. Surgical , medical & laboratory waste

 

 

  1. PRODUCT DIMENSIONS

 

Description   Dimensions

Destructive capacity  30 Kg / hour

Operation     12h/24, 6d / 7

Fuel       diesel oil

Chimney       Height: 5m, Diameter: 280mm

Volume of combustion

 

chamber Combustion: 0.3 m3

Post combustion: 0.2m3

Mixed combustion chamber: 0.3m3

` TEMPERATURES:

. Combustion

. Afterburner

900 ° C

1100 ° C

POWER BURNER

Combustion

Afterburner

 

0.11 KW

0.11 KW0

 

Fan power    0.37 kW


Animal Cremation Equipment Prices


Basic Info.

Model NO.:animal cremation equipments china
Export Markets:Global

Product Description

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Picture  
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator Maker in China.

containerised Health care center waste incinerator



One 40′ ′ ′ ′ Need – – – – containerised Heater, and likewise understand you can aid us with the purchase of the same.Waste kind or application: General in addition to Medication

Capability kgs/ human resources: 75 to 350
Clinical center and also Laboratory devices.

Among our valued customer is interested to acquire a Hospital Waste heater according to adhering to specs:

Healthcare center waste heater
Capability: 50 Kg/ Hr
Brand-new overall working system
Burners: Dual discharged (Gas and also diesel).
20ft container with an incinerator plant for melting solid waste consisting of the following important things:

1. INCINERATOR.
2. SPARK ARRESTER.
3. FLUE GAS LOT/ EXHAUST PIPELINE.
4. DIESEL OIL DAYTANK 400 L WEB.
5. INCLUDED FIRE MANAGING SYSTEM.
6. CUSTOMER’S GUIDEBOOK.
7. ADDITIONAL COMPONENTS FOR 1 YEARS PROCEDURE.
medical waste incinerator is from 2.5 to 3 cubic meters as well as additionally it’s capacity is from 60 t0 100kg per hour.



Medical Waste Incinerator PROPOSAL


1.

I. Dimension of this Incinerator 4,410 W x 3,037 L x 4,836 H mm

II. Ability of this Incinerator Medical waste 50 kg/hr. Set feeding (low level calorie worth: 4,000 5,000 kcal/kg)

III. Utility

Utility problem for the incineration apparatus operating is your sticking to.

1) Gas: moderate oil or Kerosene

two ) Electric Power

Electric Motor

-0.1– 110kW: AC 220V x 3PH x 50Hz

– – Below 0.1 kilowatt: Air Conditioner 220V x 1PH x 50Hz Control Circuit

– – MCC controller: A/C 220V x 1PH x 50Hz

– – Instrument: Air Conditioner 220V x 1PH x 50Hz

– – Switch Over Gear: Air Conditioning 220V x 1PH x 50Hz

2. Door -to-door transportation, Setup, Commissioning and Training

3. Prices quotation

– – Cost requires to be given in Ethiopian Birr (incl. VAT)


Clover's Social Media