Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
laboratory incinerator china manufacturer
Incinerator dual chamber with capacity 1.5 m3/batch or 6 m3/ day, digital thermocontrol range 0‐1200
C, thermocouple, air supply capacity 10m3/ minute, power consumption 1.2kWH/ hour, power 3
phase with netral, cooling water sprinkler capacity 5L/ minute, completed with refractory (insulation,
castable, ceramic blanket) and PLC
SUPPLY, INSTALLATION AND COMMISSIONING OF WASTE INCINERATOR – TECHNICAL SPECIFICATIONS
The Waste Incinerator is designed to burn Type IV of pathological waste and infectious, contaminated “red bag,” surgical
dressings, plastic test devices and other wastes.
General Specifications
Burner: 2 burners (primary burner and second burner)
Fuel: Oil
Capacity (Cubic Mtr): 0.65
Ave Capacity: 60 kg per hour
Fuel Consumption (ltrs / hr):13
External Dimensions
Length (mm): 2300
Width (mm): 1220
Height Incl. Flue (mm) 7000
Door Opening (mm) 610 x 710 610 x 710
Operation
Min. Operating Temperature: 950
Max. Operating Temperature: 1320
Residency Time in Second Chamber: 5 sec
Temperature Monitoring: YES
Other clarification
Easy and safe operation
Large counter-balanced fill door with electrical lockout.
Automatic control system provides preset burn times and shut off.
Reload light indicates to operator when it is time to recharge.
Be required for burnout of final charge.
Low energy consumption levels
Programmable digital temperature controls maintain temperature, assuring complete combustion while conserving fuel.
Pressure blower with modulating air control creates turbulence and distributes combustion air to secondary chamber.
Secondary burner with temperature activated modulating control provides fast preheat and sustains high temperature
performance at low energy consumption levels.
Charging rate
medical waste incinerator manufacturer
GOODS: ONE INCINERATORS IN ACCORDANCE WITH THE | SUPPLIER’ | |||||
REQUIREMENT | S | OWN | ||||
PROPOSED | ||||||
SPECIFICA | ||||||
TION/ | ||||||
CONFIRM | ||||||
ATION | ||||||
SPECS | ||||||
Incinerator walls and roof : 1550 °C castable monolithic refractory | ||||||
concrete | ||||||
Temperature: ≥90 °C | ||||||
Insulation to walls: 1000 °C castable insulation | ||||||
Electricity supply required: 220volt, 15amp single phase | ||||||
Controls | ||||||
Draught control: barometer indicator, door operated draught limiter | ||||||
Air supply: built-in forced heated air ducts, primary and secondary | ||||||
(intensifier) | ||||||
Electric: control panel includes-circuit breakers, main switch, timer, | ||||||
pilot lights, 2 set point pyrometer and one set point pyrometer | ||||||
3.Experience and Qualifications | ||||||
Experience and Qualifications | ||||||
Company | ||||||
The companies responding to this ToRs must have at least 5 year | ||||||
experience of incinerator installation and maintenance or related | ||||||
field. It must be registered, have trader’s licence and be compliant | ||||||
with tax requirements. | ||||||
Project Leader | ||||||
The proposed expert should be able to demonstrate a breadth of | ||||||
relevant experience in operations and maintenance of incinerators or | ||||||
environmental management. The project leader should have at least | ||||||
a degree in environmental management or mechanical engineering | ||||||
or related field with at least 5 year experience in project | ||||||
coordination. Previous work in Lesotho or Southern African | ||||||
Development Community (SADC) experience will be an advantage. | ||||||
Health and Safety Officer | ||||||
He/she should be a health and safety professional, such as | ||||||
occupational health and safety; safety, health and environment, with | ||||||
at least 4 years of carrying out compliance inspections and audits of | ||||||
incinerators or construction projects. A minimum of a diploma in | ||||||
health and safety or a relevant discipline is required. Prior | ||||||
experience in Lesotho will be an added advantage. | ||||||
37 |
N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set
N95 Face Mask Machine Production Line on Sale Now! $250,000USD per setN95 Face Mask Machine Production Line on Sale Now! $250,000USD per set
l Dimension(L*W*H): 1037*855*1780
l Power Supply 15.3kw mono phase
l Net Weight: approx.: 1500kg
HICLOVER – Medical Environmental
Waste IncineratorsMedical Waste IncineratorPet Animal CremationSolid Waste Incinerator
Tel: +86-25-8461 0201Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]Nanjing Clover Medical Technology Co.,Ltd.2020-04-10
incinerator manufacturer
“PYROLYTIC” combustion, by controlling the gasification of waste
The incinerator manufacturer must avoid the release of black smoke and fine dust, during the loadings.
It shall be able to reduce the volume of wastes by 98%.
It shall be able to hold emission in the second burn with gas residence of not less than 2 seconds.
The incineration should be completely free from visible smoke as well as offensive odours.
1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.
The primary combustion chamber shall be constructed from heavy steel plate and the unit is internally lined with a
complete layer of hote face refractory and high efficiency insulation.
The Internal diameter of the Chimney at least: ? 400 and its height: 8 m
100 Kg/Hr Incinerator for Hospital Waste
Basic Info.
Product Description
Nanjing Clover Medical Technology Co., Ltd.
Nanjing Clover Medical Technology Co., Ltd..
The factory workshop local in liuhe Economic Development Zone, suburb of Nanjing and business office local in downtown region. Currently, incinerator line products market cover former Soviet Union region, Africa countries, Asia countries and Middle East region. From year 2010, we negotiated with upgraded technology from Europe and America producers and establish alliance relationship in the land of China market. Little incinerators, waste incinerator, creature incinerators available, clover incinerator restricted, incinerator 500kg per, incinerator china manufacturer, Regrettably, competition in other countries market, country discrimination and anxieties of intellectual property rights cause failure finally. Presentlywe investment more attempt, funding and technology advancement in our own brand, we’re to be one of the most significant incineration equipment on earth. We have trading division company for expert export business service.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |