Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Top Feeding Door Solid Waste Incinerators HICLOVER
HICLOVER Top Feeding Door Waste Incinerators▲▲▲Large Feeding Door▲▲▲Better for Animal Waste Cremation▲▲▲HICLOVER Brand Section***Primary Combustion Chamber***Secondary Combustion Chamber***Smoke Filter Chamber***Optional Wet Scrubber System(1 section or 3 sections)
Email: [email protected]
Email: [email protected]Nanjing Clover Medical Technology Co.,Ltd.
Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter difficult Safty safe safer Incinerator Shape L/ I L Loading manual big door can be by Forklift Land occupation small big Ash door same with feeding door or alone alone market share Most-CHINA/USA/INDIA Few- UK/USA Dooring open type Manual Pry bar/Hydraulic pressure Dooring Open size small big Better for medical bag waste animal waste open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke parts of an incineratorphysical method of disposing hazardous chemical wasteportable incinerators typesproper ways of waste disposal in the communityquestionnaire to ask about incinerators for collection of dataHICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator
2020-08-07
50-100-150-200 Kgs per Hr Solid Waste Incinerator for sale
Waste Incinerator Design TS150 PLC, Testimonial



Items/Model
TS150( PLC)
Photo
![]()
Principle
Waste Incineration Treatment
Burn Rate
Average 150 kg/hour
*( 50/100/200kgs/ hr optional)
Feed Capability
Standard 750kg/feeding
Control Establishing
PLC( Programmable Logic Controller Heater)
Text Steel
8mm thickness
Chamber Product
High Alumina Fire Block Wall, 1750 ℃ Rate
Paint for outdoors face
800 ° C Rate
Burning Chamber
1570L
Internal Dimensions
150x100x105cm
2nd Chamber
750L
Smoke Filter Chamber
Yes
Feed Mode
Manual
Voltage
210/230V 50/60Hz
Power
0.9 Kw
Oil Consumption (kg/hour)
Common 20.4-28.0( D.O)
Gas Intake (m3/hour)
***
Temperature Level Screen
Digital Program
Temperature Level Safety
Yes
Oil Container
300L
Feed Door
80x60cm
Chimney
10Meter
Smokeshaft Type
Stainless-steel
1st.
Gross Weight
8500kg
Outside Dimensions
300x160x280cm( without smokeshaft)
Gross Weight
8500kg
Exterior Dimensions
300x160x280cm( without smokeshaft)
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
family pet dog incinerator up for sale
1. Capability of damage in weight: 60 Kg/h.
2. It should be able to run very little less than 10 hours/day
3. This burner needs to have the ability to destroy all combustible wastes created by healthcare facilities, unique centers, research laboratories, institutes, and so forth.
4. Style Requirements: Kinds A, B, C, D, as well as E of clinical waste
5.” PYROLYTIC” burning, by taking care of the gasification of waste.
6. The burner needs to remain clear of the release of black smoke as well as likewise fantastic dust, throughout the loadings.
7. It must have the capacity to minimize the volume of wastes by 98%.
8. It should certainly be able to hold discharge in the 2nd shed with gas house of not much less than 2 secs.
9. The incineration must be entirely without noticeable smoke in addition to upseting odours.
The minimized calorific power (L.C.P) of this waste will be 3,500 kcal/kg
? The Temperature levels of burning: Minimum will be 850oC as well as likewise max 1400oC
?
The Quantity of the burning chamber: 1.200 L.
13. The Measurement of the door for filling in cm: 70 × 70.
14. Heater procedure need to be Automatic On/Off.
15. Fuel: diesel.
16. The company needs to supply needed details for the best of the installment.
This heater with “PYROLYTIC” burning need to have:.
17. A burning chamber of waste:.
* Totally restricted door for the hands-on loading of waste. The loading must be Manual, Set Lots.
* A heater of lighting which the usage is restricted to the ignition of waste.
* Frontage of loading with door seals boosted on joints, wheel of screw plug, versatile joint, as well as also loading protecting out of refractory.
low-cost medical waste incinerator
Stack:
Type: Wire Supported
MOC: Mild Steel of ISstd
Height :3 Meters or more
• PROCESS AT LEAST 1 METRIC TON OF WASTE PER DAY
• OPERABLE BY 1 PERSON, WITH NO TRAINING REQUIRED
• REGULAR MAINTENANCE CAN BE COMPLETED BY 1 PERSON WITH LIMITED TRAINING
• REGULAR MAINTENANCE SHOULD NOT EXCEED 1-HOUR PER DAY
• COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS
• ABILITY TO INCINERATE WASTE PETROLEUM, OILS, AND LUBRICANTS
• TEMPRATURES DURING THE COMBUTION PROCESS MUST EXCEED 1,500 °F FOR AT LEAST 1-HOUR
• CAN BE TRANSPORTED TO AND FROM DEPLOYMENT LOCATION IN A 20-FOOT OR SMALLER SHIPPING ISO CONTAINER
• CAPABLE OF 24 HOURS OF CONTINUOUS USE
• AUTOMATIC LOADING SYSTEM
• AUTOMATED ASH REMOVAL SYSTEM
• GAS SCRUBBING SYSTEM
• 95% REDUCTION OF SOLID WASTE
• OPERABLE WITH DIESEL, JP8, OR FUEL OIL
• CAPABLE OF BURNING 4 UNITS OF WASTE PER UNIT OF FUEL
• ABLE TO INCINERATE COMBUSTIBLE WASTE TO INCLUDE: PAPER, PLASTIC, CARDBOARD, FOOD, USED OILS, SLUDGE, OILY RAGS, AND
WOOD PALLETS.
• NO PRE-TREATMENT OF WASTE REQUIRED
• VENDOR REPAIR OFFERED AT POINT OF SHIPMENT
• FIVE (5) YEAR COMPONENT WARRANTY FROM DATE OF ACCEPTANCE
We are an aerosol manufacturing company.. Our products includes Deodorants, Anti perspirant deodorants ,air freshners,
Insect killers etc..
Incinerator Main Combustion Chamber

trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.
Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures,
eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal
for military and civil camps and remote locations where infrastructure is scarce.
other disposal methods.
Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid
cross-contamination risk and to keep waste treatment costs at acceptable level.
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd..