Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
3 Combustion Chambers MEDICAL WASTE BURNER
![]()
Model
WS-35
Image
![]()
Burning Rate
Ordinary 35 kgs/hour
Feed Ability
Average 80 kgs
Main Burning Chamber
460 Litres
Secondary Burning Chamber
200 Liters
3rd Burning Chamber
200 Litres
Smoke Filter Chamber
Damp Scrubber System
Feed Setting
Handbook
Voltage
220V
Power
2Kw
Fuel Type
All-natural Gas/LPG
Burner
Italy Original
Oil Intake (Diesel Oil)
***
Gas Consumption (Gas)
Average 24 m3n/hour
Inner Dimensions
110 x 70 x 60cm (main chamber)
Outside Measurements
160 x 100 x 180cm (without wet scrubber)
Temperature Display
Yes
Oil Container Ability( if oil gas)
***
Door Opening
50 x 50cm
Smokeshaft Length
5.0 Meters
Smokeshaft Kind
Stainless-steel
Tools Gross Weight
5000 kgs
Operation Technical Specs
Primary Chamber Temperature Level
800 ℃–– -1000 ℃
Secondary Chamber Temperature
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Burning Performance
> 98%
Waste Lower Calorific Power
3000Kcal
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
2020-03-25
Heater with Movable stage & & & & Automobile. Door and similarly Style for Pets Person Cremation Company
|
Design for Pets Cremation Service |
Movable system & & & & Vehicle. Door |
|
Independent Placement for Little Pet |
![]()
![]()
Layout
A1500
Image
![]()
Burning Rate
Average 150 kgs/hour
Feed Capacity
Standard 350 kgs/feeding
Main Burning Chamber
1500 Liters
Second Burning Chamber
500 Litres
Mix Combustion Chamber
Yes
Smoke Filter Chamber
Yes
Feed Setting
Hand-operated
Voltage
220V/380V
Gas Kind
Diesel Oil/ All-natural Gas/LPG
Heater
Italy Original
Oil Consumption (Diesel Oil)
Average 53.0 kg/hour
Gas Consumption (Gas)
Typical 63.6 m3n/hour
Inner Measurements
150 x 100 x 100cm (major chamber)
Outside Measurements
240 x 170 x 380cm (without chimney)
Temperature Level Show
Yes
Oil Container Ability ( if petroleum gas)
300 Litres
Door Opening
59 x 81cm
Chimney Size
10.0 Meters
Smokeshaft Sort
Stainless Steel
Tools Gross Weight
8000 kgs
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
2020-06-26
Msw Incinerator Msw1000
Basic Info.
Additional Info.
Product Description
MSW Model is newest layout for municipal solid waste and other solid waste. This equipment quality structural for types of website, such as hospital, environmental department, incinerator yz 20, incinerator, capacity 20 kg, incinerator, medical, 15kg, hour, incinerator; Biological waste; Hospital, incinerator: Calculations for animal cremation bureaus, etc.. CLOVER Incinerator provide upgraded models with double combustion room, mix combustion chamber and smoke filter room using refractory lines, and the combustion room temperature up to 1200 deg C.
Items/Model | MSW2000 | MSW3000 | MSW4000 | MSW5500 |
Burning Rate | 150 kgs/Hr. | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. |
Feed Capacity | 400 kgs | 600 kgs | 800 kgs | 1100 kgs |
Equipment Weight | 7600 kgs | 9500 kgs | 13000 kgs | 16500 kgs |
Primary Chamber (Liters) | 2000 | 3000 | 4000 | 5500 |
Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 |
External Dimensions (cm) | 270x185x380 | 280x230x425 | 320x220x460 | 360x220x475 |
Internal Dimensions (cm) | 180x115x96 | 240x120x105 | 257x147x108 | 300x147x125 |
Oil Tank(Liters) | 300 | 500 | 500 | 500 |
Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 |
Chimney (M) | 10 | 10 | 14 | 14 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES |
1st. Chmaber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
2nd. Chmaber Temperature | 1000degree-1200degree | 1000degree-1200degree | 1000degree-1200degree | 1000degree-1200degree |
Environmental Protection Solutions
System Solutions for Medical Waste Environmental, consisting of Waste Incineration, Smoke Discharge Treatment, High-temperature Sterilization, Waste Crusher, Needle Destroyer, Medical Waste Plan and Containerized Mobile Incinerators.
cheap incinerators
RECYCLABLE WASTE PLASTIC (NON-PVC) 218,693
CARDBOARD 85,046
PAPER 4,956
PVC 15,115
HAZARDOUS WASTE MEDICAL WASTE 1,084
SOLID WASTE CONTAMINATED WITH HYDROCARBONS 300,680
USED ENGINE OIL FILTERS 85,423
HYDROCARBON-CONTAMINATED SOILS 88,680
ORDINARY WASTE FIBERS 14,078
USED AIR FILTERS (AUTOMOTIVE AND SIMILAR) 23,149
PERSONAL PROTECTIVE EQUIPMENT (PPE), INCLUDING CONTAMINATED CLOTHING AND SIMILAR DEBRIS 130,861
Pig corpses / stray dogs and larger animal carcasses cheap incinerators –
Load capacity in the range of up to 300 kg / Burn rate approx. 50 kg per hour
Temperature Controlled Burner. Incinerators to be designed to meet the Norms of Pollution Control. Technology: Heavy-duty casing, to be a quality, rugged, reliable, economical Incinerator with relevant control, easy to operate and self-contained. Units to be pre-assembled, pre-piped, pre-wired & tested before Transport / Export.
Note: Similar Technology and / or Tenderers Proposals are welcome.
Within the framework of an environmental equipment & technology consultation and joint purchasing, this Procurement / Notary Bureau invites applicants for pre-qualification in the aim of primarily selecting capable companies to bid for the above tender.
The supply will comprise the special equipment for effective waste management as mentioned above for a new private environment contract management company with planned operations 2013 in Indonesia and Thailand, and 2015 in West & East Malaysia to carry out those professional services in order to comply with the governments safety disposal requirements for animal waste in the region and to meet the higher technical standard in this particular field in order to protect the public and contain contagious & infectious viruses and animal caused diseases. The spread of a new disease of pigs, also the ‘Nipah Virus Disease’, first evident in 1998 in S.E.Asia, which causes illness and death in both humans and pigs, is on the rise again; as well as the sudden death of sows and boars was recorded in pig farms in Malaysia and other areas in S.E. Asia.