Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

3 Combustion Chambers MEDICAL WASTE BURNER



Model

WS-35

Image

Burning Rate

Ordinary 35 kgs/hour

Feed Ability

Average 80 kgs

Main Burning Chamber

460 Litres

Secondary Burning Chamber

200 Liters

3rd Burning Chamber

200 Litres

Smoke Filter Chamber

Damp Scrubber System

Feed Setting

Handbook

Voltage

220V

Power

2Kw

Fuel Type

All-natural Gas/LPG

Burner

Italy Original

Oil Intake (Diesel Oil)

***

Gas Consumption (Gas)

Average 24 m3n/hour

Inner Dimensions

110 x 70 x 60cm (main chamber)

Outside Measurements

160 x 100 x 180cm (without wet scrubber)

Temperature Display

Yes

Oil Container Ability( if oil gas)

***

Door Opening

50 x 50cm

Smokeshaft Length

5.0 Meters

Smokeshaft Kind

Stainless-steel

Tools Gross Weight

5000 kgs

Operation Technical Specs

Primary Chamber Temperature Level

800 ℃–– -1000 ℃

Secondary Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Performance

> 98%

Waste Lower Calorific Power

3000Kcal

Primary chamber:
Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature 

sensor points with complete internal fans.
Secondary Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 

02 Sec gas residence times.
Third Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal 

fans. 02 Sec gas residence time.

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-25



Heater with Movable stage & & & & Automobile. Door and similarly Style for Pets Person Cremation Company


Design for Pets Cremation Service

Movable system & & & & Vehicle. Door

Independent Placement for Little Pet

Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business

Layout

A1500

Image

Burning Rate

Average 150 kgs/hour

Feed Capacity

Standard 350 kgs/feeding

Main Burning Chamber

1500 Liters

Second Burning Chamber

500 Litres

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Setting

Hand-operated

Voltage

220V/380V

Gas Kind

Diesel Oil/ All-natural Gas/LPG

Heater

Italy Original

Oil Consumption (Diesel Oil)

Average 53.0 kg/hour

Gas Consumption (Gas)

Typical 63.6 m3n/hour

Inner Measurements

150 x 100 x 100cm (major chamber)

Outside Measurements

240 x 170 x 380cm (without chimney)

Temperature Level Show

Yes

Oil Container Ability ( if petroleum gas)

300 Litres

Door Opening

59 x 81cm

Chimney Size

10.0 Meters

Smokeshaft Sort

Stainless Steel

Tools Gross Weight

8000 kgs


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-26


Msw Incinerator Msw1000


Basic Info.

Model NO.:MSW1000
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

MSW Model is newest layout for municipal solid waste and other solid waste. This equipment quality structural for types of website, such as hospital, environmental department, incinerator yz 20, incinerator, capacity 20 kg, incinerator, medical, 15kg, hour, incinerator; Biological waste; Hospital, incinerator: Calculations for animal cremation bureaus, etc.. CLOVER Incinerator provide upgraded models with double combustion room, mix combustion chamber and smoke filter room using refractory lines, and the combustion room temperature up to 1200 deg C.

Items/Model MSW2000 MSW3000 MSW4000 MSW5500
Burning Rate  150 kgs/Hr. 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr.
Feed Capacity  400 kgs 600 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 9500 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 3000 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270x185x380 280x230x425 320x220x460 360x220x475
Internal Dimensions (cm) 180x115x96 240x120x105 257x147x108 300x147x125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chmaber Temperature 1000degree-1200degree 1000degree-1200degree 1000degree-1200degree 1000degree-1200degree

Environmental Protection Solutions



Incinerator

System Solutions for Medical Waste Environmental, consisting of Waste Incineration, Smoke Discharge Treatment, High-temperature Sterilization, Waste Crusher, Needle Destroyer, Medical Waste Plan and Containerized Mobile Incinerators.



cheap incinerators

RECYCLABLE WASTE    PLASTIC (NON-PVC)     218,693
CARDBOARD     85,046
PAPER     4,956
PVC     15,115
HAZARDOUS WASTE    MEDICAL WASTE     1,084
SOLID WASTE CONTAMINATED WITH HYDROCARBONS     300,680
USED ENGINE OIL FILTERS     85,423
HYDROCARBON-CONTAMINATED SOILS     88,680
ORDINARY WASTE    FIBERS     14,078
USED AIR FILTERS (AUTOMOTIVE AND SIMILAR)     23,149
PERSONAL PROTECTIVE EQUIPMENT (PPE), INCLUDING CONTAMINATED CLOTHING AND SIMILAR DEBRIS     130,861
Pig corpses / stray dogs and larger animal carcasses cheap incinerators –
Load capacity in the range of up to 300 kg / Burn rate approx. 50 kg per hour

Temperature Controlled Burner. Incinerators to be designed to meet the Norms of Pollution Control. Technology: Heavy-duty casing, to be a quality, rugged, reliable, economical Incinerator with relevant control, easy to operate and self-contained. Units to be pre-assembled, pre-piped, pre-wired & tested before Transport / Export.

Note: Similar Technology and / or Tenderers Proposals are welcome.

Within the framework of an environmental equipment & technology consultation and joint purchasing, this Procurement / Notary Bureau invites applicants for pre-qualification in the aim of primarily selecting capable companies to bid for the above tender.
The supply will comprise the special equipment for effective waste management as mentioned above for a new private environment contract management company with planned operations 2013 in Indonesia and Thailand, and 2015 in West & East Malaysia to carry out those professional services in order to comply with the governments safety disposal requirements for animal waste in the region and to meet the higher technical standard in this particular field in order to protect the public and contain contagious & infectious viruses and animal caused diseases. The spread of a new disease of pigs, also the ‘Nipah Virus Disease’, first evident in 1998 in S.E.Asia, which causes illness and death in both humans and pigs, is on the rise again; as well as the sudden death of sows and boars was recorded in pig farms in Malaysia and other areas in S.E. Asia.

Clover's Social Media