Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
red bag waste incinerator
“Waste chamber
Chamber capacity 300 kg
Chamber volume .54m3
Chamber size (outside) Width: 91cm, Height: 86cm Length:
152cm
Door opening 66 x 76 cm
Height to door 84 cm
Height to top of stack 5.4 m
Suggested slab size (L x W x Thickness) 1.8
m x 2.4 m x 10 cm
Burn rate: Approximately 45 kg/hr.
Stack:
2′-14″” dia. (36 cm), 14 gauge (1.90 mm) aluminized steel,
refractory lined
8′-12″” dia. (30.5 cm), 16 gauge (1.52″
“Burners Diesel
Operation Manual timer
Electrical service Standard – 115 volt, 60 HZ, 20 amp
General Description:
Primary
Chamber: Heavy-duty steel casing
High quality refractory lining and insulation
Large full size top load door and liquid
retention sill
1 x diesel oil fired ignition burners operated on/off
Ash removal door
Chimney: Heavy-duty stainless steel
casing
1.5m length
0.6m refractory lined stack
Control Panel: Control of 1 burner
Timer control 0-12 hours
Integral fan
timer control
Temperature monitoring
Automatic Control
Cycle time set up
Ancillaries: Operating and maintenance manuals
Spares list
Ash Rake
Containerization: 20 foot shipping container with incinerator fitted
500 litre fuel tank”
Kenya Incinerator Solutions for Hospitals and Humanitarian Camps with HICLOVER
Kenya Incinerator Solutions for Hospitals and Humanitarian Camps with HICLOVER
The growing healthcare sector in Kenya has highlighted the urgent need for reliable medical waste management solutions. Hospitals and clinics across Nairobi, Mombasa, and county-level facilities must handle infectious sharps, contaminated gauze, pharmaceutical residues, and pathological waste safely and sustainably. In this context, the demand for a Kenya incinerator for hospital medical waste disposal has expanded rapidly, driven by both national regulations and donor-funded programs.
Hospital Applications with Refractory Lining
One of the key requirements for Kenyan hospitals is durability and safety under continuous high-temperature operation. Modern medical waste units from HICLOVER are built with high alumina refractory lining (65% Al₂O₃), designed to withstand up to 1750 °C. A well-constructed incinerator with refractory lining for Kenya hospitals ensures:
-
Long service life of the combustion chambers.
-
Consistent burn temperature in the range of 850–1200 °C.
-
Reduced fuel consumption thanks to high thermal retention.
-
Protection against thermal stress in high-throughput operations.
This is particularly vital for county referral hospitals, which generate large volumes of waste daily and require equipment that can operate reliably with minimal downtime.
HICLOVER TS150 PLC – A Reliable Model for Kenya
The HICLOVER TS150 PLC model, rated at 150 kg/hour, is an ideal fit for Kenya’s medium-to-large hospitals. It combines containerized mobility with advanced automation, including:
-
PLC automatic control system with optional manual override.
-
Dual combustion chambers, ensuring a minimum of 2 seconds retention time in the secondary chamber.
-
Automatic ignition with flame stabilization, reducing operator workload.
-
Corundum probe thermometers rated up to 1600 °C for accurate monitoring.
-
Optional wet scrubber to achieve compliance with NEMA and WHO emission standards.
Containerized construction allows the system to be installed without civil engineering works, making it suitable for both urban hospitals and rural county facilities.
Humanitarian Camps and Riello Burner Technology
Kenya hosts numerous UN agencies and NGO operations that support neighboring regions like Somalia and South Sudan. These humanitarian camps generate a diverse waste stream, from medical sharps to general solid waste, requiring robust disposal systems. The incinerator with Riello burner for humanitarian camps in Kenya provides dependable ignition, stable flame, and high combustion efficiency.
Riello G-series burners, widely used in HICLOVER systems, offer:
-
Low fuel consumption for diesel-fired operation.
-
Reliable ignition cycles, even in harsh field conditions.
-
Easy maintenance with available nozzle and electrode kits.
This technology ensures that humanitarian and peacekeeping camps can maintain environmental compliance while minimizing operational challenges.
Containerized and Mobile Advantages
For both hospitals and humanitarian projects, mobility is a decisive factor. HICLOVER’s containerized mobile incinerators are built into ISO containers or trailer-mounted designs, offering:
-
Rapid deployment in emergency response or refugee camp settings.
-
Weatherproof housing suitable for East African conditions.
-
Secure, fire-resistant construction with integrated chimneys.
-
Compatibility with dual-fuel operation (diesel and gas).
This mobility ensures that waste treatment capacity can be relocated as projects shift, a key requirement for NGOs and UN agencies operating across Kenya’s borders.
Conclusion
Kenya’s healthcare facilities and humanitarian operations demand high-quality incineration systems that combine durability, efficiency, and mobility. From a Kenya incinerator for hospital medical waste disposal to an incinerator with refractory lining for Kenya hospitals, and even an incinerator with Riello burner for humanitarian camps in Kenya, HICLOVER provides tailored solutions to match local needs. With models like the TS150 PLC and optional wet scrubber systems, HICLOVER supports Kenya’s commitment to safe, sustainable, and compliant waste management.
For inquiries:
Website: www.hiclover.com
Email: sales@hiclover.com
Mobile (WhatsApp): +86-13813931455
Incinerators at 3 facilities to refine medical care waste
a. 2.5 metric heaps daily health care waste burner
b. 1.5 metric heaps daily healthcare waste burner
c. 300 kg daily medical care waste burner
Our favored technology is double-chamber incineration, but if you propose a different modern technology, that is okay.
We request information on the following for every of the above demands:
1. Capital cost (provided expense in Oman)
2. Operation as well as upkeep expenses (yearly )
3. Number of motorists called for
4. Item specs (sizes, temperature levels, home time, cycle time )
5. Various other auxiliary equipment That’s needed or recommended by you
Small Scale Incinerator for Solid Waste
Basic Info.
Product Description
Items | Specification | ||||
Model | TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) | ||||
Main Product List | Double Combustion Chamber | ||||
Smoke Filter Chamber | |||||
PLC Mode Control Case | |||||
Stainless Steel Chimney | |||||
Italy oil/gas burner: 02 units | |||||
Oil Tank (if oil fuel) |
General requirements of a 100 kg/hr 3 combustion Chambers Burner
General specifications of a 100 kg/hr incinerator | |||
No. | Description | Parameter value | |
model | HICLOVER YD100 | ||
1 | Machine working mode | Oil + Power | Oil + Power |
2 | Voltage | 220V C 3 phase or 1 phase | 220V 1P |
3 | Oil consumption (lit/hr) | Average 25-32 lit/hr/chamber | Average 33Liters/hour/total incinerator 3 burners |
6 | Incineration rate | 100 kg/hr = 400-600 kg/8hr | average 100kgs per hour |
7 | Feed mode | Manual | manual |
8 | Primary combustion rate | 1000 lit | 1080 liters |
9 | Secondary combustion rate | 240 lit | 207 Liters |
10 | Tertiary combustion rate | 416 lit | 452 liters |
11 | Combustion chamber material | High temp. resistant concrete | High temp. resistant concrete |
12 | Internal dimensions (1st chamber) | 100*100*100 cm (l*w*h) = 1000 lit | 120*100*90cm(l*w*h) = 1080 lit |
13 | Internal dimensions (2nd chamber) | 40*40*150 cm = 240 lit | Diameter 42*150cm=207 Liters |
14 | Internal dimensions (3rd chamber) | 40*40*260 cm = 416 lit | Diameter 60*160cm=452 Liters |
15 | External dimensions | 300*155*200 cm (l*w*h) | 220*160*370 cm (l*w*h) |
16 | Door opening | 90*90 cm | 90*90 cm |
17 | Additional air fan | 1 fan (on the door) | 1 fan (on the door) |
18 | Fuel type | Diesel oil/ | Diesel oil |
19 | Burner | Brand: Radiator or Hofmat | Italy Baltur |
20 | Chimney length | 3-4 meters | 5 Meters |
21 | Chimney type and material | H-type stainless steel, or High temp. resistant concrete | 1 Meter High temp. resistant concrete +4 Meter Stainless steel |
22 | Smoke and smell filter | Yes, two stages. | Dry Scrubber 2 stages |
23 | Temperature monitor | Yes, (for 1st and 3rd chambers) | Yes, (all 3 chambers) |
24 | Temperature control | Optional | yes |
25 | Oil tank | 500 lit needed. | yes |
26 | Burning efficiency | >98% | yes |
27 | 1st chamber temperature | 300-700 oC | 800-1000 oC |
28 | 2nd chamber temperature | 500-1000 oC | 1000-1200 oC |
29 | 3rd chamber temperature | 800-1200 oC | 1000-1300 oC |
30 | Smoke residency time | >2 sec. | >2 sec. |
31 | Gross weight | 5-8 tons | average 6.5 Ton |
32 | No. of Burners | 3 | 3 |

Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]