Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

red bag waste incinerator


“Waste chamber

Chamber capacity 300 kg

Chamber volume .54m3

Chamber size (outside) Width: 91cm, Height: 86cm Length:

152cm

Door opening 66 x 76 cm

Height to door 84 cm

Height to top of stack 5.4 m

Suggested slab size (L x W x Thickness) 1.8

m x 2.4 m x 10 cm

Burn rate: Approximately 45 kg/hr.

Stack:

2′-14″” dia. (36 cm), 14 gauge (1.90 mm) aluminized steel,

refractory lined

8′-12″” dia. (30.5 cm), 16 gauge (1.52″

“Burners Diesel

Operation Manual timer

Electrical service Standard – 115 volt, 60 HZ, 20 amp

General Description:

Primary

Chamber: Heavy-duty steel casing

High quality refractory lining and insulation

Large full size top load door and liquid

retention sill

1 x diesel oil fired ignition burners operated on/off

Ash removal door

Chimney: Heavy-duty stainless steel

casing

1.5m length

0.6m refractory lined stack

Control Panel: Control of 1 burner

Timer control 0-12 hours

Integral fan

timer control

Temperature monitoring

Automatic Control

Cycle time set up

Ancillaries: Operating and maintenance manuals

Spares list

Ash Rake

Containerization: 20 foot shipping container with incinerator fitted

500 litre fuel tank”


Kenya Incinerator Solutions for Hospitals and Humanitarian Camps with HICLOVER

Kenya Incinerator Solutions for Hospitals and Humanitarian Camps with HICLOVER

The growing healthcare sector in Kenya has highlighted the urgent need for reliable medical waste management solutions. Hospitals and clinics across Nairobi, Mombasa, and county-level facilities must handle infectious sharps, contaminated gauze, pharmaceutical residues, and pathological waste safely and sustainably. In this context, the demand for a Kenya incinerator for hospital medical waste disposal has expanded rapidly, driven by both national regulations and donor-funded programs.

Hospital Applications with Refractory Lining

One of the key requirements for Kenyan hospitals is durability and safety under continuous high-temperature operation. Modern medical waste units from HICLOVER are built with high alumina refractory lining (65% Al₂O₃), designed to withstand up to 1750 °C. A well-constructed incinerator with refractory lining for Kenya hospitals ensures:

  • Long service life of the combustion chambers.

  • Consistent burn temperature in the range of 850–1200 °C.

  • Reduced fuel consumption thanks to high thermal retention.

  • Protection against thermal stress in high-throughput operations.

This is particularly vital for county referral hospitals, which generate large volumes of waste daily and require equipment that can operate reliably with minimal downtime.

HICLOVER TS150 PLC – A Reliable Model for Kenya

The HICLOVER TS150 PLC model, rated at 150 kg/hour, is an ideal fit for Kenya’s medium-to-large hospitals. It combines containerized mobility with advanced automation, including:

  • PLC automatic control system with optional manual override.

  • Dual combustion chambers, ensuring a minimum of 2 seconds retention time in the secondary chamber.

  • Automatic ignition with flame stabilization, reducing operator workload.

  • Corundum probe thermometers rated up to 1600 °C for accurate monitoring.

  • Optional wet scrubber to achieve compliance with NEMA and WHO emission standards.

Containerized construction allows the system to be installed without civil engineering works, making it suitable for both urban hospitals and rural county facilities.

Humanitarian Camps and Riello Burner Technology

Kenya hosts numerous UN agencies and NGO operations that support neighboring regions like Somalia and South Sudan. These humanitarian camps generate a diverse waste stream, from medical sharps to general solid waste, requiring robust disposal systems. The incinerator with Riello burner for humanitarian camps in Kenya provides dependable ignition, stable flame, and high combustion efficiency.

Riello G-series burners, widely used in HICLOVER systems, offer:

  • Low fuel consumption for diesel-fired operation.

  • Reliable ignition cycles, even in harsh field conditions.

  • Easy maintenance with available nozzle and electrode kits.

This technology ensures that humanitarian and peacekeeping camps can maintain environmental compliance while minimizing operational challenges.

Containerized and Mobile Advantages

For both hospitals and humanitarian projects, mobility is a decisive factor. HICLOVER’s containerized mobile incinerators are built into ISO containers or trailer-mounted designs, offering:

  • Rapid deployment in emergency response or refugee camp settings.

  • Weatherproof housing suitable for East African conditions.

  • Secure, fire-resistant construction with integrated chimneys.

  • Compatibility with dual-fuel operation (diesel and gas).

This mobility ensures that waste treatment capacity can be relocated as projects shift, a key requirement for NGOs and UN agencies operating across Kenya’s borders.

Conclusion

Kenya’s healthcare facilities and humanitarian operations demand high-quality incineration systems that combine durability, efficiency, and mobility. From a Kenya incinerator for hospital medical waste disposal to an incinerator with refractory lining for Kenya hospitals, and even an incinerator with Riello burner for humanitarian camps in Kenya, HICLOVER provides tailored solutions to match local needs. With models like the TS150 PLC and optional wet scrubber systems, HICLOVER supports Kenya’s commitment to safe, sustainable, and compliant waste management.

For inquiries:
Website: www.hiclover.com
Email: sales@hiclover.com
Mobile (WhatsApp): +86-13813931455

Mobile: +86-13813931455(WhatsApp)

Email:     sales@hiclover.com     
Email:     hicloversales@gmail.com 

 

2025-09-03/13:40:53

Incinerators at 3 facilities to refine medical care waste


a. 2.5 metric heaps daily health care waste burner

b. 1.5 metric heaps daily healthcare waste burner

c. 300 kg daily medical care waste burner

Our favored technology is double-chamber incineration, but if you propose a different modern technology, that is okay.

We request information on the following for every of the above demands:

1. Capital cost (provided expense in Oman)

2. Operation as well as upkeep expenses (yearly )

3. Number of motorists called for

4. Item specs (sizes, temperature levels, home time, cycle time )

5. Various other auxiliary equipment That’s needed or recommended by you


Small Scale Incinerator for Solid Waste


Basic Info.

Model NO.:smokeless crematorium
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Items Specification
Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC)
Main Product List Double Combustion Chamber
Smoke Filter Chamber
PLC Mode Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

General requirements of a 100 kg/hr 3 combustion Chambers Burner


General specifications of a 100 kg/hr incinerator
No. Description Parameter value  
  model   HICLOVER YD100
1 Machine working mode Oil + Power Oil + Power
2 Voltage 220V C 3 phase or 1 phase 220V 1P
3 Oil consumption (lit/hr) Average 25-32 lit/hr/chamber Average 33Liters/hour/total incinerator 3 burners
6 Incineration rate 100 kg/hr = 400-600 kg/8hr average 100kgs per hour
7 Feed mode Manual manual
8 Primary combustion rate 1000 lit 1080 liters
9 Secondary combustion rate 240 lit 207 Liters
10 Tertiary combustion rate 416 lit 452 liters
11 Combustion chamber material High temp. resistant concrete High temp. resistant concrete
12 Internal dimensions (1st chamber) 100*100*100 cm (l*w*h) = 1000 lit 120*100*90cm(l*w*h) = 1080 lit
13 Internal dimensions (2nd  chamber) 40*40*150 cm = 240 lit Diameter 42*150cm=207 Liters
14 Internal dimensions (3rd  chamber) 40*40*260 cm = 416 lit Diameter 60*160cm=452 Liters
15 External dimensions 300*155*200 cm (l*w*h) 220*160*370 cm (l*w*h)
16 Door opening 90*90 cm 90*90 cm
17 Additional air fan 1 fan (on the door) 1 fan (on the door)
18 Fuel type Diesel oil/ Diesel oil
19 Burner Brand: Radiator or Hofmat Italy Baltur
20 Chimney length 3-4 meters 5 Meters
21 Chimney type and material H-type stainless steel, or High temp. resistant concrete 1 Meter High temp. resistant concrete +4 Meter Stainless steel
22 Smoke and smell filter Yes, two stages. Dry Scrubber 2 stages
23 Temperature monitor Yes, (for 1st and 3rd chambers) Yes, (all 3 chambers)
24 Temperature control Optional yes
25 Oil tank 500 lit needed. yes
26 Burning efficiency >98% yes
27 1st chamber temperature 300-700 oC 800-1000 oC
28 2nd chamber temperature 500-1000 oC 1000-1200 oC
29 3rd chamber temperature 800-1200 oC 1000-1300 oC
30 Smoke residency time >2 sec. >2 sec.
31 Gross weight 5-8 tons average 6.5 Ton
32 No. of Burners 3 3


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 


Clover's Social Media