Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

Large Scale Municipal Waste Incinerator


Basic Info.

Type:Incinerator
Export Markets:Global

Product Description

Key Attributes:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to sequence * High fever, long life of incinerator.  * Free or minimum installation onsite.  * High speed, from biology waste 2b waste burner, biomedical incinerator available, biomedical waste china, biomedical waste incinerator manufacturers in china, brainwaves systems center east, 10kgs to 500kgs per hourto 6ton daily.  *according to order  New Design for pet animal cremation enterprise.  * One year warranty on incinerator and parts in stock.  Application Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Incinerator


Basic Info.

Model NO.:30 kg per hour
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Items/Model TS30(PLC)
Burn Rate 30 kg/hour
Feed Capacity 60kg
Control Mode PLC
Combustion Chamber 330L
Internal Dimensions 75x75x60cm
Secondary Chamber 180L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.5Kw
Oil Consumption (kg/hour) 10.2–20
Gas Consumption (m3/hour) 9.8–20
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 55x50cm
Chimney 5Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800 degree –1000 degree
2nd. Chamber Temperature 1000 degree –1200 degree
Residency Time 2.0 Sec.
Gross Weight 3000kg
External Dimensions 175x120x140cm

Principle of the Incinerator Gear is incineration/combustion/burn.

three chamber system incinerator

The primary factors considered in the design and construction of a modified De-Montfort type intermittent incinerator for combusting medical wastes were the waste types, fuel, chimney size, and flue gas residence time. The design analysis was based on flue gas flow rate of 0.13 m3/s, maximum primary chamber temperature of 870 °C and minimum ambient temperature of 27 °C. The total flue gas residence time of 6.9 s was achieved for the three chamber system of 0.9 m3 total volume. The medical wastes generated from the four medical facilities in Ga East District (Ghana) consisted of infectious sharp objects, syringes, wound dressings and gloves; which were incinerated at a throughput of 80 kg/day with destruction efficiency of 98.47 %, using fuelwood as primary fuel. The natural convection thermo-fluid flow was controlled by ambient wind speed of ~ 3.8 ms-1, at temperature of 31.5 °C. The primary combustion chamber temperature attained was ~ 516 °C, while the third chamber temperature reached 760 °C, which ensured complete combustion of the wastes with reduced particulate matter emissions. At optimum operating capacity of 0.6 m3, up to 4 cycles of incineration were done in a day, each cycle lasting about 80 minutes.

3 Burning Chambers MEDICAL WASTE BURNER


Variation

WS-35

Picture

Burning Price

Typical 35 kgs/hour

Feed Capacity

Regular 80 kgs

Main Burning Chamber

460 Liters

Additional Burning Chamber

200 Litres

3rd Burning Chamber

200 Litres

Smoke Filter Chamber

Damp Scrubber System

Feed Mode

Guidebook

Voltage

220V

Power

2Kw

Gas Type

All-natural Gas/LPG

Heating System

Italy Original

Oil Intake (Diesel Oil)

***

Gas Consumption (Natural gas )

Normal 24 m3n/hour

Internal Dimensions

110 x 70 x 60cm (trick chamber)

Outside Measurements

160 x 100 x 180cm (without moist scrubber)

Temperature Display

Yes

Oil Storage Tank Ability( if petroleum gas)

***

Door Opening

50 x 50cm

Smokeshaft Dimension

5.0 Meters

Smokeshaft Kind

Stainless-steel

Equipment Gross Weight

5000 kgs

Procedure Technical Specs

Secret Chamber Temperature Level

800 ℃–– – – -1000 ℃

Added Chamber Temperature Degree

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Effectiveness

> 98 percent

Waste Lower Calorific Power

Primary chamber:
Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature 

sensor points with complete internal fans.
Secondary Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 

02 Sec gas residence times.
Third Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal 

fans. 02 Sec gas residence time.

HICLOVER – Medical Environmental 

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-25


Clover Incinerator update Social media site, including facebook,twitter,linkedin

we now publish mutil-social media for incinerator online marketing, this will be helpful our marketing and customer relationship.

 

http://www.facebook.com/hiclover

https://twitter.com/hiclovercom

https://www.linkedin.com/in/hiclover

https://plus.google.com/+IncineratorClover

https://www.youtube.com/c/IncineratorClover

https://www.pinterest.com/incinerators

http://cloverincinerator.blogspot.com/

http://cloverincinerator.tumblr.com/

http://vk.com/hiclover

https://www.instapaper.com/p/incinerator

https://www.flickr.com/photos/clover-incinerator/

 

 

 

Clover's Social Media