Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Burner to reduce black bag garbage dump waste
30 August 2013 Last upgraded at 21:18 BST
Five councils in south eastern Wales have developed a partnership to take care of black bag waste in a proposal to minimize rubbish going to garbage dump.
Write-up valued quote from the network
Environment contributor Iolo ap Dafydd reports.
Article priced quote from the network
20 Kgs Capacity Medical Incinerator
Product Description
Key Features: * All models with Dual combustion room. *according to sequence * High temperature, long lifetime of incinerator. * Free or minimum installation onsite. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. *according to order New Design for pet animal cremation enterprise. * One year warranty on incinerator and components in stock.
Nanjing Clover Medical Technology Co., Ltd.. Is a top waste incinerator manufacturer in China. We’re local producer and among the greatest exporter of China. Pyrolytic incinerator gear technical is main waste treatment each one of the world, for Medical Waste, Animal Incineration, home waste incinerator in china, hospital burner manufacturere, hospital diesel fuel fired incinerators, hospital gear burner 100kg per day, hospital incinerater, Pet cremation and other good wste. The potential from 10kgs/Hr. To 500kgs/Hr. Up to 6ton per day. Presently, we provide different series for local customer requirements and layout updated incinerator with our top technology. The updated design characteristic of our assortment of incinerators make them among the most cost effective in the world.
Items/Model | YD-10C | YD-20C | YD-30C | YD-50C |
Burning Rate (kgs/Hour) | 10 kgs/Hr. | 20 kgs/Hr. | 30 kgs/Hr. | 50 kgs/Hr. |
Feed Capacity (kgs) | 40 kgs | 40 kgs | 50 kgs | 80 kgs |
Equipment Weight | 1200 kgs | 1200 kgs | 1800 kgs | 2200 kgs |
Primary Chamber (Liters) | 200 | 200 | 250 | 400 |
Secondary Chamber (Liters) | 140 | 140 | 140 | 140 |
External Dimensions (cm) | 170x140x160 | 170x140x160 | 170x140x190 | 180x160x200 |
Internal Dimensions (cm) | 55x55x65 | 55x55x65 | 55x55x85 | 70x70x85 |
Oil Tank(Liters) | 50 | 100 | 100 | 150 |
Door Opening (cm) | 38 x 48 | 38 x 48 | 38 x 48 | 45×55 |
Chimney (M) | 5 | 5 | 5 | 5 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES |
Heater YD-100 for Iraq
There are 03 sets Design YD-100 circulation to Iraq between year 2013 to 2014. The heater use for neighborhood a number of structure as well as construction sites in addition to all gas kind is diesel oil.
Items/Model | YD-100 |
Burning Rate (kgs/Hour) | 100 kgs/Hr. |
Feed Capacity (kgs) | 200 kgs |
Equipment Weight | 5300 kgs |
Primary Chamber (Liters) | 1200 |
Secondary Chamber (Liters) | 500 |
External Dimensions (cm) | 220x180x360 |
Internal Dimensions (cm) | 130x100x90 |
Oil Tank(Liters) | 300 |
Door Opening (cm) | 55 x 80 |
Chimney (M) | 10 |
Chimney Type | Stainless Steel |
Secondary Chamber | YES |
Mix-Combustion Chamber | YES |
Smoke Filter Chamber | YES |
Combustion Fuel | Oil/Gas |
Residency Time | 2.0 Sec. |
Temperature Monitoring | YES |
1st. Chmaber Temperature | 800℃–1000℃ |
2nd. Chmaber Temperature | 1000℃-1200℃ |
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
waste incinerator manufacturer china

The incinerator burn waste in primary combustion chamber and burn off the smoke from primary combustion room again to make sure environmentally friendly with no smoke, smelless, decrease pathogenic bacteria disease. System solutions for medical waste ecological, such as waste incineration, smoke cessation treatment, high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc..
incinerator manufacturers
2.1 General Description
The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The controlled sections may contain but not Limited to:
B) Ensure secondary air supply is controlled.
D) Ensure that the gas temperature measured against the inside wall in the secondary chamber and not in the fire zone is not less than 1100 degrees centigrade.
3. Assessment and preparation and construction of a normal incinerator drop with one waste storage space ( see the design )
4. Provision of operation and maintenance manuals and drawings complete with maintenance program and instructions. Fuel oil storage tank- Mild steel1500 liters capacity
6. Onsite training for operation and maintenance employees.
IMPORTANT
9. Ought to have a complete width counterbalance loading door allowing easy access to the main chamber for loading and removing ash.
E) A strong particulate meter/recorder should be provided.
F) Ensure both primary and secondary combustion temperatures are maintained until all waste is totally combusted. The particulate collectors may comprise any of the following or a combination thereof:
6. The stack/chimney.
O) The purpose for measurement of emissions will be provided.
2.7 Instrumentation
a) Instrument for determining the interior wall temperature and not burner flame temperature must be provided for both primary and secondary chambers.
2.3 Main Combustion Chamber.
a) This chamber should be outfitted with burners using low sulphur gas.
B) An audible and visible alarm must be set up to warn the operator once the secondary chamber temperature falls to below the specified temperature.
M ) The chimney should be visible to the operator from the feeding place.
E) All the emission to the atmosphere aside from steam or water vapour must be odourless and totally free of mist, fume and droplets.
B) The chamber should ensure a minimal exit temperature of 850 degrees centigrade.
D) Opacity of this smoke shouldn’t exceed 20% seen by 50 yards with naked eyes.
2. Feed chamber/charging
2. Provision for adherence to OSHA and other statutory requirement relating to Health and Safety of employees during execution of the works covered in this tender.
F) Any other instrument which may be considered necessary.
2.9 Emission Limits
a) Combustion efficiency (C.E) shall be 99.00percent at which C.E =%Carbon dioxide x 100 / [% Carbon dioxide + carbon dioxide ]
b) Electrostatic precipitators
1. Overall plant layout
Capacity/island: 4000 kg/day; 25000 kg/day; 31000 kg/day; 48000 kg/day
Burning temperature — more than 12000C
Two chambers — minimal
Emissions — dioxin and heavy metaly — better afterward Kyoto protocol
Emission — tracking method
Waste unloiding — straight from squander monitor to incinerator
d) A smoke density meter/recorder should be provided.
5.
C ) The secondary chamber gas residence time will probably be 1 second at 1050 +/- 50 degrees centigrade with 3% oxygen in the stack gas.
7. Minimum capacity of primary chamber = 0.18 cubic metres
a) Cyclone separator
Supply, Installation and Commissioning of An Incinerator in Eastern Hydros [ Page 28
2.2 Feeding and Fixing
3. Main combustion chamber
C ) Ensure residence time is not less than two seconds.
4. Particulate scrubbers
Controlled hygienic mechanical feeding that does not negatively influence the atmosphere temperature in the primary and secondary chambers of the incinerator will be used.
G) The average dioxin and furan concentration in the emission should not exceed 80mg/m3 total dioxins and furans if quantified for an interval of 6 to 16 hours.
– Manual technical monitoring is shipped with the hardware together with explanations of failures and settlements
8. Burn speed (speed of waste incineration) = at least 20 kg each hour
1.
C ) Fabric filters
2.6 Chimney/Stack
l) The chimney should have a minimum height of 10 metres above ground level and clear the maximum point of the building by not less than 3 metres for all roofs. The topography and height of adjacent buildings within 50 metres radius should be taken into account.
E) Ensure the emitted oxygen content of the emitted gases is not less than 11%
N ) The minimum exit rate should be 10 metres per second and at least two times the encompassing wind speed (Efflux velocity = wind speed x 2) whichever is higher to ensure no down washing of leaving gases.
1.
Burning temperature – over 12000C
Two chambers – minimum
Emissions – dioxin and heavy metaly – better then Kyoto protocol
Emission – monitoring system
Waste unloiding – directly from waste track to incinerator