Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Latest Product

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

Hospital Incinerator


Basic Info.

Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Items Specification
Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC)
Main Product List Double Combustion Chamber
Smoke Filter Chamber
PLC Mode Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Efficient stove technology Alleviates N. Kenya’s Health waste problem


WAMBA, Kenya, June 30 (Thomson Reuters Foundation) – Poor weather, security threats and bad roads have made disposing of the Wamba district hospital’s medical waste a challenge.

The nearest incinerator is roughly 200 kilometres (125 miles) away and “travelling wasn’t possible during heavy rains because connecting roads were cut off by flooding,” said Stephen Lesrumat, a medic in the hospital.

But now the north-central Kenyan hospital has an answer to its problems, and a way of cutting climate changing emissions and deforestation: A high-efficiency medical waste incinerator that uses just a fifth time the fuel of a traditional incinerator.

The wood burner, that takes advantage of strong winds in the area to drive the fires, borrows technology in fuel-efficient stoves. It can safely eliminate waste made by the Wamba hospital and from 22 other health centres in Samburu County, said Lesrumat and Ibrahim Lokomoi, the facility’s engineer.

“It has reduced the burden of traveling outside the county to eliminate medical waste,” Lesrumat said, sparing hospitals a possibly dangerous build-up of medical waste during periods when roads are impassible.

During previous flood periods, when hospital waste couldn’t be hauled, “I was stressed because the waste is poisonous,” Lesrumat said. “it might lead to health and environment damage if it accidentally spilled into the community. ”

Run-ins with al Shabaab militants may also be a hazard for some healthcare employees in Kenya driving long distances in their jobs, medics said.

“Northern Kenya is quite expansive and contains so many challenges that the government struggles to deliver services,” said Onyango Okoth the assistant commissioner of Samburu County.

Now the Wamba incinerator handles between 5 and 20 kilograms of medical waste a day.

As the burner works, a young worker clad in protective garments flips open the lid of the chamber to monitor the practice of incineration.

Viewing the last batch of waste is all but eliminated, he reaches for a barrel containing an assortment of used rubber gloves, syringes and polythene waste, pours in some of their waste, combines it with a forked rod then replaces the lid to allow the incineration to last.

The Centers for Diseases Control in Kenya estimates that every patient admitted in a hospital creates at least 0.5 kilograms of medical waste.

The following step, Kenyan clean energy experts say, may be to start incinerating waste using even more renewable resources of electricity, such as solar power.

“Kenya is investing heavily in alternative energy sources,” said Johnson Kimani of the Kenya Climate Change Working Group. “Solar and biogas must be factored in to medical waste incineration in the event the government is committed to the assurance of achieving a green economy. ”

James Lebasha, of the International Medical Corps, that helped assemble the Wamba incinerator, said the burner might be just the very first for the area.

“We hope to build additional units in morthern Kenya to allow communities access this service,” he said. (Reporting from Kagondu Njagi; editing by Laurie Goering:; Please credit the Thomson Reuters Foundation, the charitable arm of Thomson Reuters, that covers diplomatic news, climate change, girls ’s rights, trafficking and corruption.

“We hope to build more units in morthern Kenya to enable communities access this service,” he said. (Reporting by Kagondu Njagi; editing by Laurie Goering :; Please credit the Thomson Reuters Foundation, the charitable arm of Thomson Reuters, that covers humanitarian news, climate change, women’s rights, trafficking and corruption. Visit www.trust.org/climate)

from: http://www.reuters.com/article/2015/06/30/kenya-medical-energy-idUSL8N0ZG1M220150630


Twin Chamber Incinerator


Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Nanjing Clover Medical Technology Co., Ltd., Neighborhood in Nanjing city, China.

Incinerator


Basic Info.

Model NO.:50 kgs per hour
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Principle of This Incinerator equipment is incineration/combustion/burn.

Items/Model TS50(PLC)
Burn Rate 50 kg/hour
Feed Capacity 100kg
Control Mode PLC
Combustion Chamber 560L
Internal Dimensions 100x80x70cm
Secondary Chamber 280L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.7Kw
Oil Consumption (kg/hour) 12.1–24
Gas Consumption (m3/hour) 9.9–26.1
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 70x55cm
Chimney 5Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800 degree –1000 degree
2nd. Chamber Temperature 1000 degree -1200 degree
Residency Time 2.0 Sec.
Gross Weight 4500kg
External Dimensions 230x130x155cm
 

Contemplating Environmental Protection demands and rules, virtually all incinerator have secondary combustion chamber (after-burn, post-combustion), even when third combustion room. The secondary burner burn the Exhaust gas from primary combustion chamber, this technologies make sure sufficient combustion, few black smoke and smell.  The updated incinerator technology focus on Exhaust gas treatment to remove Hazardous material and other purpose from incinerator, such as heat recovery (waste to energy), save fuel expenditure, PLC Automation operation.  In certain Developed nations, some new waste treatment method such as High-temperature cooking, waste carbonization, devastating sterilization technology is instead of incineration technology.

Biomedical Waste Incinerator


Basic Info.

Model NO.:aravali incinerator of 30 kg per hour capacity co
Power Source:Diesel
Type:Incinerator
Usage:Incinerator
Export Markets:Global

Product Description

Items Specification
YD Model YD-30 / YD-50 / YD-100 / YD-150 / YD-200 / YD-300 / YD-500 / YD-600
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Nanjing Clover Medical Technology Co., Ltd..

Clover's Social Media