Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Hospital Incinerator
Basic Info.
Additional Info.
Product Description
Items | Specification | ||||
Model | TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) | ||||
Main Product List | Double Combustion Chamber | ||||
Smoke Filter Chamber | |||||
PLC Mode Control Case | |||||
Stainless Steel Chimney | |||||
Italy oil/gas burner: 02 units | |||||
Oil Tank (if oil fuel) |
Efficient stove technology Alleviates N. Kenya’s Health waste problem
WAMBA, Kenya, June 30 (Thomson Reuters Foundation) – Poor weather, security threats and bad roads have made disposing of the Wamba district hospital’s medical waste a challenge.
The nearest incinerator is roughly 200 kilometres (125 miles) away and “travelling wasn’t possible during heavy rains because connecting roads were cut off by flooding,” said Stephen Lesrumat, a medic in the hospital.
But now the north-central Kenyan hospital has an answer to its problems, and a way of cutting climate changing emissions and deforestation: A high-efficiency medical waste incinerator that uses just a fifth time the fuel of a traditional incinerator.
The wood burner, that takes advantage of strong winds in the area to drive the fires, borrows technology in fuel-efficient stoves. It can safely eliminate waste made by the Wamba hospital and from 22 other health centres in Samburu County, said Lesrumat and Ibrahim Lokomoi, the facility’s engineer.
“It has reduced the burden of traveling outside the county to eliminate medical waste,” Lesrumat said, sparing hospitals a possibly dangerous build-up of medical waste during periods when roads are impassible.
During previous flood periods, when hospital waste couldn’t be hauled, “I was stressed because the waste is poisonous,” Lesrumat said. “it might lead to health and environment damage if it accidentally spilled into the community. ”
Run-ins with al Shabaab militants may also be a hazard for some healthcare employees in Kenya driving long distances in their jobs, medics said.
“Northern Kenya is quite expansive and contains so many challenges that the government struggles to deliver services,” said Onyango Okoth the assistant commissioner of Samburu County.
Now the Wamba incinerator handles between 5 and 20 kilograms of medical waste a day.
As the burner works, a young worker clad in protective garments flips open the lid of the chamber to monitor the practice of incineration.
Viewing the last batch of waste is all but eliminated, he reaches for a barrel containing an assortment of used rubber gloves, syringes and polythene waste, pours in some of their waste, combines it with a forked rod then replaces the lid to allow the incineration to last.
The Centers for Diseases Control in Kenya estimates that every patient admitted in a hospital creates at least 0.5 kilograms of medical waste.
The following step, Kenyan clean energy experts say, may be to start incinerating waste using even more renewable resources of electricity, such as solar power.
“Kenya is investing heavily in alternative energy sources,” said Johnson Kimani of the Kenya Climate Change Working Group. “Solar and biogas must be factored in to medical waste incineration in the event the government is committed to the assurance of achieving a green economy. ”
James Lebasha, of the International Medical Corps, that helped assemble the Wamba incinerator, said the burner might be just the very first for the area.
“We hope to build additional units in morthern Kenya to allow communities access this service,” he said. (Reporting from Kagondu Njagi; editing by Laurie Goering:; Please credit the Thomson Reuters Foundation, the charitable arm of Thomson Reuters, that covers diplomatic news, climate change, girls ’s rights, trafficking and corruption.
“We hope to build more units in morthern Kenya to enable communities access this service,” he said. (Reporting by Kagondu Njagi; editing by Laurie Goering :; Please credit the Thomson Reuters Foundation, the charitable arm of Thomson Reuters, that covers humanitarian news, climate change, women’s rights, trafficking and corruption. Visit www.trust.org/climate)
from: http://www.reuters.com/article/2015/06/30/kenya-medical-energy-idUSL8N0ZG1M220150630
Twin Chamber Incinerator
Basic Info.
Additional Info.
Product Description
Items/Model | YD-10C | YD-20C | YD-30C | YD-50C |
Burning Rate (kgs/Hour) | 10 kgs/Hr. | 20 kgs/Hr. | 30 kgs/Hr. | 50 kgs/Hr. |
Feed Capacity (kgs) | 40 kgs | 40 kgs | 50 kgs | 80 kgs |
Equipment Weight | 1200 kgs | 1200 kgs | 1800 kgs | 2200 kgs |
Primary Chamber (Liters) | 200 | 200 | 250 | 400 |
Secondary Chamber (Liters) | 140 | 140 | 140 | 140 |
External Dimensions (cm) | 170x140x160 | 170x140x160 | 170x140x190 | 180x160x200 |
Internal Dimensions (cm) | 55x55x65 | 55x55x65 | 55x55x85 | 70x70x85 |
Oil Tank(Liters) | 50 | 100 | 100 | 150 |
Door Opening (cm) | 38 x 48 | 38 x 48 | 38 x 48 | 45×55 |
Chimney (M) | 5 | 5 | 5 | 5 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES |
Nanjing Clover Medical Technology Co., Ltd., Neighborhood in Nanjing city, China.
Incinerator
Basic Info.
Additional Info.
Product Description
Principle of This Incinerator equipment is incineration/combustion/burn.
Items/Model | TS50(PLC) |
Burn Rate | 50 kg/hour |
Feed Capacity | 100kg |
Control Mode | PLC |
Combustion Chamber | 560L |
Internal Dimensions | 100x80x70cm |
Secondary Chamber | 280L |
Smoke Filter Chamber | Yes |
Feed Mode | Manual |
Voltage | 220V |
Power | 0.7Kw |
Oil Consumption (kg/hour) | 12.1–24 |
Gas Consumption (m3/hour) | 9.9–26.1 |
Temperature Monitor | Yes |
Temperature Protection | Yes |
Oil Tank | 100L |
Feed Door | 70x55cm |
Chimney | 5Meter |
Chimney Type | Stainless Steel |
1st. Chamber Temperature | 800 degree –1000 degree |
2nd. Chamber Temperature | 1000 degree -1200 degree |
Residency Time | 2.0 Sec. |
Gross Weight | 4500kg |
External Dimensions | 230x130x155cm |
Contemplating Environmental Protection demands and rules, virtually all incinerator have secondary combustion chamber (after-burn, post-combustion), even when third combustion room. The secondary burner burn the Exhaust gas from primary combustion chamber, this technologies make sure sufficient combustion, few black smoke and smell. The updated incinerator technology focus on Exhaust gas treatment to remove Hazardous material and other purpose from incinerator, such as heat recovery (waste to energy), save fuel expenditure, PLC Automation operation. In certain Developed nations, some new waste treatment method such as High-temperature cooking, waste carbonization, devastating sterilization technology is instead of incineration technology.
Biomedical Waste Incinerator
Basic Info.
Product Description
Items | Specification | |||
YD Model | YD-30 / YD-50 / YD-100 / YD-150 / YD-200 / YD-300 / YD-500 / YD-600 | |||
Main Product List | Primary Combustion Chamber | |||
Secondary Combustion Chamber | ||||
Mix Combustion Chamber | ||||
Smoke Filter Chamber | ||||
Incinerator Common Control Case | ||||
Stainless Steel Chimney | ||||
Italy oil/gas burner: 02 units | ||||
Oil Tank (if oil fuel) |
Nanjing Clover Medical Technology Co., Ltd..