Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Medical Waste Burner
Product Description
Nanjing Clover Medical Technology Co., Ltd..
Item | Customer Request | Example |
Application Scope | |
Hospital, Pet Crematory, Slaughter House, Laboratories, School, Community, etc. if for animal/pet, indicate animal size like: cat, dog, cattle, etc |
What kind of waste? | ____, _____% ____, _____% ____, _____% |
Medical waste, dead animal, Municipal Waste, etc(detail name) or nature percent if for animal/pet, indicate animal size like: cat, dog, cattle, etc |
Quantity Request | 01.02.03^…unit |
|
Budget | $US Dollar. |
|
Operating Time | The staff work Hours per day. Our incinerator can work up to around 18 hours per day. |
|
Realization Date of project | In ___ year | |
Waste Output Capacity per Day? | |
1000kgs Per Day^ |
Request waste burn rate | Capacity: 100kgs Per hour^ | |
Request waste feed capacity | Capacity: 100kgs per feed^ | |
Whether Natural Gas Supply Local? | Yes or No. | |
Local Power | If 380V and 220V valid? | |
Product Installation Destination | |
Country or City name |
DestinationSeaport name? | To check sea freight charge. |
|
Customer | End-Customer, Agent, Government. |
|
Method of contract | Tender or Negotiation | |
Date of Tender limit | ||
How did you know our company? | ||
Other request or information | |
Key Features: * All versions with Dual combustion room. *based on order * High fever, long lifetime of incinerator. * Free or minimal installation onsite. * High burn rate, from 10kgs to 500kgs per hourto 6ton daily. * PLC Control Plane. *based on order * New Design for pet animal cremation enterprise. * One year guarantee on incinerator and parts in stock.
Moving Forward on Open Waste Burning
“Is there anything that we can post to get more folks involved? Yes, petitions, a letter campaign… When the EPA was pushed to the wall Louisiana, they stated ‘Uncle. ’ We need you Senator Kaine and you Senator Warner to do just what Senator Vitter failed in Louisiana and write to the EPA and ask them, ‘How is this not a violation of the clean air act? ’”
Devawn Oberlender is seeking to have a pager from the publication of a far away city, where taxpayer protestors succeeded in stopping outside burning explosives of arms and weapons waste in the Louisiana Army Ammunition Plant.
“The opportunity that we have right now only comes up very ten decades, because the license is good for ten decades, so what we need to replicate is what they did in north western Louisiana in Camp Minden.
There they formed a”Stop the Burn” movement that ultimately brought together elected officials, state and local authorities and the army for a strategy to give up open burning and utilize a contemporary indoor incinerator to eliminate the toxic substances.
“We haven’t reached any decisions yet but this is something that will be looked at as we proceed. We have requested the Arsenal to come up with alternatives to open burning and we do expect to have some options that go beyond the idea of simply burning it the open”
Brian Salvatore is a professor of Organic chemistry at Louisiana State University who argued for utilizing comprised incineration.
“This is exactly what we fought here in camp Minden. And yes it added another 15million dollars and nearly doubled the price of this contract but that was something that, the EPA was willing to really go to bat for us . So I’m thankful that the people in the EPA and in the country worked together here and they worked together with the Army as well to locate the extra cash. And we’re quite happy here that this alternative — that, in the onset of this we didn’t know all the particulars of exactly what these modern incinerators can do. We are quite confident here that this will do the task and the total amount of material that’s going to be published complete is going to be on the order of tens of thousands of grams rather than heaps of those emissions. ”
A spokesman for the Environmental Protection Agency’s Region 3, which includes Virginia, stated it could not comment on the chance of incinerators such as that being adopted at the Radford site, but a spokesperson for BAE Systems, the contractor responsible for the arsenal, supported it is”searching for workable alternatives to its existing methods of waste disposal”
The section of Environmental Quality has requested BAE to conduct an environmental impact study on its own present open burning clinic. William Hayden says it is the first time DEQ has requested for you.
“Since we’re getting into a problem that has generated a lot of public attention in the Radford area we understood that the further information we had, the better. Folks from the public have been asking for us info; they have been asking Radford (the arsenal) for advice. ”
And among these is Oberlender who says,”We have been burning waste out there, open it since 1941. You know, it is not going away.”
And neither are the ecological patriots of this river valley. Taking another page from the narrative of Camp Minden Louisiana’s successful effort to get its outside burning moved indoors. They’re scheduling meetings with federal and state officials to keep the strain. The first is this Friday with U.S. Representative Morgan Griffith who sits on the Committee on Energy and Commerce, which has oversight of the EPA. The team is seeking to generate a national issue out of one that has for so long been so local and among the few areas where open burning of hazardous waste out of explosives is still allowed.
Info from: http://wvtf.org/post/moving-forward-open-burning
The license that enables the Radford Army Ammunitions Plant to burn hazardous waste from guns outdoors is up for renewal. Community activists see a chance to address environmental and health concerns regarding the burning — and say regulators see a chance to explore new technology to fix an old problem.
Ydc Model Incinerator
Basic Info.
Additional Info.
Product Description
Nanjing Clover Medical Technology Co., Ltd..
Key Features: * All versions using Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. *according to order * High fever, long lifetime of incinerator. * Free or minimum installation on site. * High burn speed, from 10kgs to 500kgs per hour, up to 6ton daily. * PLC Control Plane. *according to order New Design for pet animal cremation enterprise. * One year warranty on incinerator and parts in stock.
Product List | ||||
Items | Specification | |||
YDC Model | YD-10C / YD-20C / YD-30C / YD-50C | |||
Main Product List | Primary Combustion Chamber | |||
Secondary Combustion Chamber | ||||
Mix Combustion Chamber | ||||
Smoke Filter Chamber | ||||
Incinerator Common Control Case | ||||
Stainless Steel Chimney | ||||
Italy oil/gas burner: 02 units | ||||
Oil Tank (if oil fuel) |
YDC incinerator is newest design for waste treatment, include health care waste, animal cremation and other solid waste. This gear quality structural for kinds of site, such as hospital, environmental department, animal cremation services, etc… CLOVER Incinerator provide updated versions with dual combustion chamber, mix combustion chamber and smoke filter chamber using refractory lines, along with the combustion chamber temperature up to 1200 deg C.
Incinerator Program
Basic Info.
Additional Info.
Product Description
The incinerator lines have little scale to large scale, up to 500kgs per hour. The combustion chamber use high strength stuff, expensive cost but better quality than rivals. Incinerator operation system use PLC program control manner, give up the complicated manual operation.
How you can find reasonable incinerator to your community website? Incinerator isn’t a cheap equipment, normally the little scale model's price around $5, 000usd per unit and big scale model's price more than $50, 000usd per unit. Thus, before buy incinerators medical treatment procedures, incinerators portable, incinerators suppliers, incinerators used in laboratories, incinerators vietnam, 1 device incinerator, you have to make clear after items: A, burn what? Incinerator is a incineration gear, function is flame squander. So what sort of waste you want to cure? B, little or big? This based on the waste output daily or the waste quantity per feed time, like animal size. Incinerator use oil or gas fuel, normally, gas fuel is cheaper than oil and also the smoke cleaner than petroleum fuel model. But some neighborhood website don't have gasoline supply system.
Items | Specification | ||||
Model | TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) | ||||
Main Product List | Double Combustion Chamber | ||||
Smoke Filter Chamber | |||||
PLC Mode Control Case | |||||
Stainless Steel Chimney | |||||
Italy oil/gas burner: 02 units | |||||
Oil Tank (if oil fuel) |
Oil Incinerator
Basic Info.
Additional Info.
Product Description
Incinerator is a incineration gear, direct fire waste by gas fuel or oi gas. As different circumscription, incinerator can be termed many words as under:
Treatment ability: Small scale incinerator, big scale incinerator and incineration pant. Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators Incinerator gas: Gas incinerator, oil incinerator Waste to Energy (WTE): WTE incinerator, non-WTE incinerator Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. We have re-designed the incinerators lining configuration. We have also designed and installed our own own PLC computer system into incinerator functioning system. Clover understand it is Incinerator research, incinerator sampah, incinerator little, incinerator little scale waste oil, incinerator little size 100 kg, incinerator smart ash review, important that build them better, keep it simple and give a great service. We make quality products which give excellent revenge on investment, our incinerators will be the most powerful and thermally efficient in the industry.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800–1000 degree | 800–1000 degree | 800–1000 degree | 800–1000 degree | 800–1000 degree |
2nd. Chamber Temperature | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |