Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Hospital Incinerator
Basic Info.
Product Description
Waste Incinerator International Market Analytics Date.
Key Word: Small incinerators Medical waste incinerator Pet animal cremation incinerator Incinerator manufacturers
Incinerator is a incineration equipment, direct fire waste from gas fuel or oi gas. As different circumscription, incinerator could be termed many words as under:
Treatment ability: Small scale incinerator, large scale incinerator and incineration pant. Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators Incinerator gas: Gas incinerator, oil incinerator Waste to Energy (WTE): WTE incinerator, non-WTE incinerator Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. All around the planet, in many nations, individuals anti incinerator since the incinerator will produce a large Dioxin from the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological features. Dioxins could be released into the environment through woods fires, backyard burning of trash, certain industrial activities, and residue from past business burning of waste. Dioxins break down very slowly and previous releases of dioxins from both man-made and natural sources still exist from the surroundings. Anyhow, we have to remind this, that is large scale incineration pant, normally greater than 30 ton per day. This is a societal issue, to examine and indicate ways in different angles in the public, government, economic development, environmental protection, technology development, etc.
So, why people use incinerator? First, for your medical waste from hospital, the pyrolytic incinerators is greatest treatment up to now. Pyrolytic technology can ruin the virus, pollution management. Second, for human body, pet animal, in many nations and areas, we desire to cremation them. This is the ceremony in the procedure for society development, and ceremonies to commemorate the disappearance of existence.
As previously two reason although not just above, we nevertheless utilize incinerators.
How you are able to discover reasonable incinerator to your local website? Incinerator isn’t a cheap equipment, normally the small scale model's cost around $5, 000USD per unit and large scale model's cost more than $50, 000USD per unit. So, before buy one unit incinerator, you need to make clear after items: A, burn out what? Incinerator is a incineration equipment, function is fire waste. So what sort of waste that you want to treatment? B, small or large? Combustion equipment animal cremation furnace, 'concrete combustion incinerator',” clover incinerator” that,”animal crematorium equipment”,”biomedical waste” gasifier certification,”china solid waste net”, This based on the waste output daily or the waste volume per feed time, like animal dimension. Incinerator use gas or oil , normally, gas fuel is cheaper than oil and also the smoke cleaner than oil fuel model. However, some local website don't have gas distribution system. Along with other tech products, like electricity (220V, 380V), waste feed door kind, incinerator structure, etc..
Once you clarify these, you can go to discover a local or international manufacturers, asking prices, technical specifications and ultimately purchasing the right products.
Wrote by Nicky
Items/Model | YD-30 | YD-50 | YD-100 | YD-150 | Items/Model | YD-200 | YD-300 | YD-500 | YD-600 | Items/Model | YD-200 | YD-300 | YD-500 | YD-600 |
Burning Rate (kgs/Hour) | 30 kgs/Hr. | 50 kgs/Hr. | 100 kgs/Hr. | 150 kgs/Hr. | Burning Rate (kgs/Hour) | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. | 600 kgs/Hr. | Burning Rate (kgs/Hour) | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. | 600 kgs/Hr. |
Feed Capacity (kgs) | 60 kgs | 150 kgs | 200 kgs | 300 kgs | Feed Capacity (kgs) | 400 kgs | 500 kgs | 800 kgs | 1100 kgs | Feed Capacity (kgs) | 400 kgs | 500 kgs | 800 kgs | 1100 kgs |
Equipment Weight | 2300 kgs | 4000 kgs | 4300 kgs | 7000 kgs | Equipment Weight | 7600 kgs | 8300 kgs | 13000 kgs | 16500 kgs | Equipment Weight | 7600 kgs | 8300 kgs | 13000 kgs | 16500 kgs |
Primary Chamber (Liters) | 360 | 900 | 1200 | 1500 | Primary Chamber (Liters) | 2000 | 2400 | 4000 | 5500 | Primary Chamber (Liters) | 2000 | 2400 | 4000 | 5500 |
Secondary Chamber (Liters) | 200 | 200 | 500 | 500 | Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 | Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 |
External Dimensions (cm) | 145x90x175 | 200x160x230 | 220x180x360 | 240x170x380 | External Dimensions (cm) | 270 x 185 x 380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 | External Dimensions (cm) | 270 x 185 x 380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 |
Internal Dimensions (cm) | 100x60x60 | 120x90x85 | 130x100x90 | 150x100x96 | Internal Dimensions (cm) | 180 x 115 x 96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 | Internal Dimensions (cm) | 180 x 115 x 96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 |
Oil Tank(Liters) | 200 | 300 | 300 | 500 | Oil Tank(Liters) | 300 | 500 | 500 | 500 | Oil Tank(Liters) | 300 | 500 | 500 | 500 |
Door Opening (cm) | 48 x 60 | 62 x 80 | 55 x 80 | 59 x 81 | Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 | Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 |
Chimney (M) | 5 | 5 | 10 | 10 | Chimney (M) | 10 | 10 | 14 | 14 | Chimney (M) | 10 | 10 | 14 | 14 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES | Secondary Chamber | YES | YES | YES | YES | Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES | Mix-Combustion Chamber | YES | YES | YES | YES | Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES | Smoke Filter Chamber | YES | YES | YES | YES | Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES | Temperature Monitoring | YES | YES | YES |
Burner of Medical Waste Automatically
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste may use in this gear? A: This gear for medical waste, pet animal, Municipal waste, live squander. Prohibit any explosive and radiation substance, liquid gas and waste waste. GB18484-2001. The animal/pet combustion rate around 2/3 of average power.
Clover incinerator use time daily to 24 hours. Between each feed/combustion time, you will find about 0.5-1 hours cooling time and time for feeding squander. Actual combustion time per day is about 16 hours. The lifetime of incinerator between 5-10 year based on use.
Ordinarily, we proposition small lab, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output around 2kgs per individuals per day. If there are 200 sickbed at the hospital, that's imply you need one incinerator capacity around 400kgs per day, change to power per hour is around 30-40 kgs per hour. According the performance time per day, waste material, funding, growth, etc, you may use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Assembly and Testing A: We provide all files and incinerators easy to setup and functionality. Client can send individuals come to our factory to learn operation and installation. Generally, we don’t send engineer to neighborhood website or even request. The dispatch cost is additional based on order. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control mode is common control instance. PLC mode based on order and model.
Q: Operation and maintenance costs A: Operation cost based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD annually maintenance according model, use situation.
One individual can service 02 device incinerators. The staff should have fundamental electrician incinerator 50 kg, incinerator 500 kg, incinerator animal, incinerator burner, incinerator burner model including cremation croupes, incinerator catalogue, incinerator combustion capacity, knowledge to operate/inspect/maintaince incinerator/burner/blower based on performance user guider, and also know threat of medical waste to safeguard worker self with necessary protection element.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician incinerator 50 kg, incinerator 500 kg, incinerator animal, incinerator burner, incinerator burner model for cremation croupes, incinerator catalog, incinerator combustion capacity, knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Dual Chamber Incinerator for Hazardous Waste
Basic Info.
Product Description
1.
4. Shipping Document & Packing: Generally, We supply (1)Bill of Lading (Way Bill), what's sample…(2)Commercial Invoice, (3)Packing List ONLY.
If any further documents/certification and label print/words on packing material or documents which request by importer or local customs, whatever happen in China or oversea, should inform seller in advance and charge as actual cost. For example, Fumigation Certification, embassy certificate, BV/SGS…Inspection, certificate of original (C/O), hospital incinerator Italy, hospital incinerator USA, hospital incinerators, incenerator biological price, incenerator in China, Form A, etc. Buyer must to inform seller in advance and pay these cost. Seller save all rights to postpone/cancel shipping and request lost cost cause this incident. If the importer local customs arrest/request penalty or other situation caused by buyer mistake, Clover Medical save all right to request compensation/litigation. Thanks for your cooperation.
5. The leading time is mostly 3-6 weeks, depending on the products and quantity.
7. Guarantee: One year for the equipment. We supply spare parts for maintenance, free charge within the first year and the delivery charge is on the buyer.
8. Insurance: Bear all risks of loss of or damage to the goods from the time they have passed the ship's rail at the named port of shipment. We proposal apply All Risks insurance under each contract. When buyer pickup goods at local site, must inspect carefully. If any damage happened under insurance policy, buyer should inform insurance company and Clover Medical Limited immediately. We will provide necessary assistance.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Build Secondary Combustion Incinerator Stove
Product Description
Nanjing Clover Medical Technology Co., Ltd..
Key Features: * All models with Dual combustion room. * Stainless Steel chimney/stack, long life. *based on order * High temperature, long life of incinerator. * Free or minimum installation onsite. * High speed, from 10kgs to 500kgs per hourto 6ton per day. *based on order New Design for pet animal cremation enterprise. * One year warranty on incinerator and components in stock.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Application Scope: 1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 3. Community & Sea Port & Station: Municipal Solid Waste, etc. 4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation Company License No.,: 320105000138343
Waste Materials with Ability of 50 Kg/Hr
Product Description
Nanjing Clover Medical Technology Co., Ltd..
Key Features: * All versions with Dual combustion room. * Stainless Steel chimney/stack, long lifetime. *based on sequence * High temperature, long lifetime of incinerator. * Free or minimal installation on site. * High burn rate, from 10kgs to 500kgs per hourto 6ton per day. * PLC Control Plane. *based on order * New Design for pet animal cremation business. * One year guarantee on incinerator and parts in stock.
Items | Specification | ||||
Model | TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) | ||||
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Main Product List | Double Combustion Chamber | ||||
Smoke Filter Chamber | |||||
PLC Mode Control Case | |||||
Stainless Steel Chimney | |||||
Italy oil/gas burner: 02 units | |||||
Oil Tank (if oil fuel) |
Application Scope: 1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 3. Community & Sea Port & Station: Municipal Solid Waste, etc. 4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation Company License No.,: 320105000138343