Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

medical small incinerator


Dimensions: World standard: 0.83m(I) x 1.0m(w) x 1.4m(h)

Burning efficiency: >98% china double chamber incinerator

Features:

?     Waste type and burn rate: Designed specifically for use by poultry

farmers, game-keepers and for pet cremation. The incinerator will burn

up to 50 kg of waste per hour.

?     Construction: Mild steel welded fabrication consisting of sheet

steel and structural section supports.

?     Lining: Monolithic high grade refractory concrete with high grade

insulation backing. Typical hot face temperature lining up to 1300o C

?     Burner: LPG oil/natural gas/bio gas fire/ Diesel

?     Loading- Ash removal: Lower railed ash door for easy ash removal.

?     Exterior finish: Multi-coat high quality, high-temperature aluminum

enamel  top coat paint, finished in silver.

Control: Manual temperature display

 

 

 

Refractory walls and roof

5 mm mild steel

Heavy angle and channel

1550 degree Celsius castable general purpose high strength, high abrasion resistant monolithic refract concrete

High grade cast iron

5 mm mild steel lined with 1550 degree Celsius castable general prupose high strength, high abrasion resistant

monolithic refractory concrete

1550 degree Celsius castable general prupose high strength, high abrasion resistant monolithic refractory concrete

 

13   Refractory concrete – alumina content  At least 48%

14   Refractory thickness  Not thinner than 102 mm but in primary chamber minimum 152 mm and 125 mm thick

15   Insulation to walls      1000 degree castable insulation

16   Chimney stack

Chimney

Diameter of chimney at top

Weight of stack

5 mm mild steel

Minimum 430 mm

Approx 500 kg

17   Controls

Barometer damper

Door operated draught limiter

Air supply: built in forced draught heated air primary and secondary (intensifier)

Control panel includes circuit breakers, main switch, timer, 2 set point pyrometer and one set point pyrometer,

thermometer


little healthcare center waste incinetor



WASTE INCINERATOR

–          150 KG/HR

–          Compliant with EU rules, Directive 2000/76/EC

–          Fuel type: Diesel

–          Easy management and maintenance

–          Temperatures:

850 deg C for municipal waste

1000 deg C for medical waste

1100 deg C for dangerous waste containing halogenated organic substances with content of chlorine or its compounds.a incinerator with an avarage burning capacity of 20-30kgs per hour and it should diesel or used motor oil,  MEDICAL INCINERATORS, CAP: 3 TONS.producer of small hospital waste incinetor – for our clients (hospitals)



medical incinerator design


It is expected that the Bidder will cooperate closely with PATH and target Hospitals for the new waste handling

building/area and will make available all needed technical information, drawings, etc.,

 

The following waste streams shall be treated in the new HCW treatment center(s):

 

Infectious waste

 

Sharps waste

 

Pathological waste

 

Pharmaceutical waste including cytotoxic or genotoxic waste

 

Small amounts of chemical waste

TECHNICAL SPECIFICATION FOR PROCUREMENT OF “MEDICAL WASTE TREATMENT PLANT”

Lot-A

Specification

1.Hydroclave for Medical waste Treatment Plant: Quantity: 02 Nos.

General Requirements

The processor must be approved to sterilize  & treat the following types of medical waste:

-Liquids: Blood, body fluids etc.

-Blood bags & tubing, gloves, Gowns, drapes, etc.

-Contaminated packaging: bandage etc.

-Sharps & Sharp containers

-Disposable instruments

-Glass products

-Human and animal tissue (surgical and pathologic) –Based upon MWM regulations

-Cultures, stocks and glassware

The processor must comply with a documented efficacy level of 6log10 reduction in spore survival (99,9999%) of the

Bacillus Stearothermophilus

The processor should reduce the volume of the waste by 60% to 80% through complete dehydration and sterilization of

the waste

The  processor must have ZERO harmful emission level and meet or exceed all standards required by the EU.

The whole waste treatment system should be offered as a complete unit consisting of following equipment and

ancillaries-

(A)The sterilization processing unit

(B)Steam Boiler

(C)Tub washer

(D)Heavy duty external shredder-

(E)Conveyer belt-based on Manufacturer’s Recommendations

(F)Bin Lift/Tipper

(G)Spore tester

(A)Features and Specifications of the Sterilization Processor unit:

Technical specification of the processor:

Steam autoclave in combination with a heavy duty Fragmenting System inside the vessel/chamber

The vessel must be of Double Chamber

Capacity (kg/load) : minimum 200 kg/batch/cycle

Volume of 140-190 liters of bulk per cycle

Average Cycle time : 60 minutes

Operating temperature: 121◦C to 135◦C

Operating pressure : 1.1 Bar to 2.4 Bar


contaminated materials treatment and also disposal



Our items make sure reliable, clean as well as hassle-free disposal of clinical waste is possible. The incineration of clinical waste including pathological waste (red bag waste), Biohazards & & Sharps, General Medical Waste, from Medical Facilities, Proving Ground, Drug Companies, Medication Makes, Medical Care Trusts, Plastic Surgery Facilities, Nursing Residences, Treatment Houses and also various other Professional Waste.incinerators uk, community strong waste burner, cremation prosser



Clover's Social Media