Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
medical small incinerator
Dimensions: World standard: 0.83m(I) x 1.0m(w) x 1.4m(h)
Burning efficiency: >98% china double chamber incinerator
Features:
? Waste type and burn rate: Designed specifically for use by poultry
farmers, game-keepers and for pet cremation. The incinerator will burn
up to 50 kg of waste per hour.
? Construction: Mild steel welded fabrication consisting of sheet
steel and structural section supports.
? Lining: Monolithic high grade refractory concrete with high grade
insulation backing. Typical hot face temperature lining up to 1300o C
? Burner: LPG oil/natural gas/bio gas fire/ Diesel
? Loading- Ash removal: Lower railed ash door for easy ash removal.
? Exterior finish: Multi-coat high quality, high-temperature aluminum
enamel top coat paint, finished in silver.
Control: Manual temperature display
Refractory walls and roof
5 mm mild steel
Heavy angle and channel
1550 degree Celsius castable general purpose high strength, high abrasion resistant monolithic refract concrete
High grade cast iron
5 mm mild steel lined with 1550 degree Celsius castable general prupose high strength, high abrasion resistant
monolithic refractory concrete
1550 degree Celsius castable general prupose high strength, high abrasion resistant monolithic refractory concrete
13 Refractory concrete – alumina content At least 48%
14 Refractory thickness Not thinner than 102 mm but in primary chamber minimum 152 mm and 125 mm thick
15 Insulation to walls 1000 degree castable insulation
16 Chimney stack
Chimney
Diameter of chimney at top
Weight of stack
5 mm mild steel
Minimum 430 mm
Approx 500 kg
17 Controls
Barometer damper
Door operated draught limiter
Air supply: built in forced draught heated air primary and secondary (intensifier)
Control panel includes circuit breakers, main switch, timer, 2 set point pyrometer and one set point pyrometer,
thermometer
little healthcare center waste incinetor
WASTE INCINERATOR
– 150 KG/HR
– Compliant with EU rules, Directive 2000/76/EC
– Fuel type: Diesel
– Easy management and maintenance
– Temperatures:
850 deg C for municipal waste
1000 deg C for medical waste
1100 deg C for dangerous waste containing halogenated organic substances with content of chlorine or its compounds.a incinerator with an avarage burning capacity of 20-30kgs per hour and it should diesel or used motor oil, MEDICAL INCINERATORS, CAP: 3 TONS.producer of small hospital waste incinetor – for our clients (hospitals)
medical incinerator design
It is expected that the Bidder will cooperate closely with PATH and target Hospitals for the new waste handling
building/area and will make available all needed technical information, drawings, etc.,
The following waste streams shall be treated in the new HCW treatment center(s):
Infectious waste
Sharps waste
Pathological waste
Pharmaceutical waste including cytotoxic or genotoxic waste
Small amounts of chemical waste
TECHNICAL SPECIFICATION FOR PROCUREMENT OF “MEDICAL WASTE TREATMENT PLANT”
Lot-A
Specification
1.Hydroclave for Medical waste Treatment Plant: Quantity: 02 Nos.
General Requirements
The processor must be approved to sterilize & treat the following types of medical waste:
-Liquids: Blood, body fluids etc.
-Blood bags & tubing, gloves, Gowns, drapes, etc.
-Contaminated packaging: bandage etc.
-Sharps & Sharp containers
-Disposable instruments
-Glass products
-Human and animal tissue (surgical and pathologic) –Based upon MWM regulations
-Cultures, stocks and glassware
The processor must comply with a documented efficacy level of 6log10 reduction in spore survival (99,9999%) of the
Bacillus Stearothermophilus
The processor should reduce the volume of the waste by 60% to 80% through complete dehydration and sterilization of
the waste
The processor must have ZERO harmful emission level and meet or exceed all standards required by the EU.
The whole waste treatment system should be offered as a complete unit consisting of following equipment and
ancillaries-
(A)The sterilization processing unit
(B)Steam Boiler
(C)Tub washer
(D)Heavy duty external shredder-
(E)Conveyer belt-based on Manufacturer’s Recommendations
(F)Bin Lift/Tipper
(G)Spore tester
(A)Features and Specifications of the Sterilization Processor unit:
Technical specification of the processor:
Steam autoclave in combination with a heavy duty Fragmenting System inside the vessel/chamber
The vessel must be of Double Chamber
Capacity (kg/load) : minimum 200 kg/batch/cycle
Volume of 140-190 liters of bulk per cycle
Average Cycle time : 60 minutes
Operating temperature: 121◦C to 135◦C
Operating pressure : 1.1 Bar to 2.4 Bar
contaminated materials treatment and also disposal
Our items make sure reliable, clean as well as hassle-free disposal of clinical waste is possible. The incineration of clinical waste including pathological waste (red bag waste), Biohazards & & Sharps, General Medical Waste, from Medical Facilities, Proving Ground, Drug Companies, Medication Makes, Medical Care Trusts, Plastic Surgery Facilities, Nursing Residences, Treatment Houses and also various other Professional Waste.incinerators uk, community strong waste burner, cremation prosser
Environmental Protection Solutions
System Solutions for Medical Waste Environmental, including Waste Incineration, Smoke Emission Treatment, High-temperature Sterilization, Waste Crusher, Needle Destroyer, Medical Waste Package and Containerized Mobile Incinerators.