Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

diesel oil fired medical waste incenerator

High Temperature Waste Incinerator Model D. MB 750XL Burn Rate-150Kg/hour minimum Weight(Kg)-4000kg Secondary Chamber

(double chamber with post-burning) Gas Retention Time 2 second Fuel Diesel Power Supply for control box 220V-240, single

phase 50-60Hz Minimum operating temperature 1200 oC One year spare parts package for complete maintainability 10m hose

pipe. 1100 litre fuel Tank +pipe system Containerised (the container will serve as housing) Additional chimney extension

1 metre high One (1) year warranty.

Incinerator of 20 Kg : 03 Units

Electrically controlled incinerator.

Two-compartment incinerator with a capacity of 20 kg / hour.

Incinerator with low maintenance and operating costs; Equipped with an automatic control panel and easy to use with

electromagnetic locking of the door.

A main waste reduction chamber of 900 ° C. A post secondary combustion chamber of gases generated in the primary chamber

at least 1100 ° C.

Carbon residues in ash less than 5% by weight in accordance with European Directive 2000/76 / EC.

With refractory lining in materials of higher quality
1/ Cost of a 200kgs/Hr medical waste incinerator.
2/ (CIF Term) Cost of shipping from factory to PAPUA NEW GUINEA seaport of LAE, Morobe province
3/ Cost of 2 Clover engineers to Supervise, Installation, Training our engineers and commissioning the medical; waste

incinerator.

scientific waste incinerator up for sale



Waste kind: health care waste
Waste density: 125 to 350Kg/M3
Waste calorific well worth: 4000KCAL/kg
Dampness web content: 10– – 25%. Approximated ash deposit: 5– – 10%. Nominal ability: 50kg/hr set lots.
2nd chamber: 2 [e-mail       protected] C.
Environmental: NEMA ACT (EMCA) 1999, Waste Keeping track of plans, 2006.
Trick Burning chamber:.
The major burning chamber is the significant structure of the heater, produced from moderate steel plate in addition to tensed with rolled steel areas.

It is carried from the floor covering level on a considerable steel support structure. Inside the covering is lined with calcium silicate insulation as well as likewise a warm face combination of incredibly commitment brickwork or high stamina castable.

The main burning chamber must make certain minimum separation temperature level is not much less than 850? C.
One Hand-operated Lots Burner making up:.
Hand-operated loading door.
Straight strong fireplace, refractory lined primary burning chamber. Approximate. dimensions 800x2100mm( DxL).
Total sized mass load/ash elimination door.
1 off diesel-fired ignition burner– – temperature level managed.
1 off combustion air supply follower as well as distribution system, automated control.
High capacity second burning chamber with residence time very little less than 2 secs @ >> 850? C.
1 off diesel-fired afterburner– – temperature regulated.
Control panel– – automated treatment.
Temperature indicator additional and also primary chambers 0-1200? C.
Refractory lined flanged chimney to an elevation of 10M above ground level.
NB: The extra combustion chamber must make certain that the gas temperature level as gauged versus the within wall in the 2nd chamber & & & & not in the fire area, is not less than 1100? C

Throughput: 50kg/hr at a small calorific worth of 4,000 kca/kg as well as a typical mass density of 120kg/m3 for fundamental waste in addition to 160kg/m3 for healthcare waste.
Ash: The waste will be lowered by 90 ~ 95% to leave 10-5% ash.
Quality/Environmental Criteria: NEMA ACT (EMCA) 1999, BS3316.
Running period: prepared for day-to-day operating period 8 hours.
Maximum operating period: 12 hrs.
Chamber: must be refractory lined to the list below need;.
Hearth as well as additionally lowered section of chamber wall surface surfaces.
Warm face item:.
Super obligation firebrick.
Restricting constant solution restriction 1500? C.
Thickness: 100mm.
Thermal conductivity: 1.3 W/mk.
Insulation:.
Calcium silicate.
Limiting continual solution limit 1000? C.
Density: 25mm.
Thermal conductivity: 0.095 W/mk.
Chimney/Stack: Ought to be made from refractory lined modest steel or superb high quality air-cooled s/s.
The chimney/stack should have a minimal height of 10m over ground degree.
Ignition heating units: fully packaged oil kind, overall with electrical ignition in addition to fire failing controls, wired with continuous running follower in addition to complete with all shutoffs, fan as well as electric motor.
Optimum score: a minimum of 450kW/hr.
Heater: set up on/off procedure.
Maximum consumption: at the very least 6Ltrs/hr.
Typical intake: a minimum of 3Ltrs/hr.
Afterburner:.
fully packaged oil kind, total with electric ignition as well as additionally fire stopping working controls, wired with continual running fan as well as also amount to with all valves, fan as well as additionally motor.
Optimum rating: at the very least 450kW/hr.
Heating unit: arranged for on/off treatment.
Maximum use: at the very least 9Ltrs/hr.
Common usage: at the very least 4.5 Ltrs/hr.
Flue gas therapy: should have particle eliminator (scrubbers).
Electric supply: solitary stage: 220/240VAC; 50/60Hz

Documents:.
scientific waste heater to buy Procedure manual: 2 collections.
Service/maintenance manual: 2 sets.
Certification: NEMA (or other identified) certification.
Capability to solution tools: the agent/supplier will have sufficient centers, extra parts, consumables as well as likewise certified skilled technical team.
Training: the Agent will execute a 2 days heaters training after installment and likewise selecting of the devices.

The Rep will certainly do a 2 days procedure & & & & upkeep training to the Biomedical design workers after installation & & & & appointing of the devices.



Medical Waste Incinerator


Basic Info.

Model NO.:medical waste bin manufacturer in china
Export Markets:Global

Product Description

Key Attributes:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to order  * High fever, long life of incinerator.  * Free or minimal installation onsite.  * High burn rate, from 10kgs to 500kgs per hourto 6ton per day.  * PLC Control Plane. *according to order  New Design for pet animal cremation business.  * One year warranty on incinerator and components in stock. 

Program Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation 

TS model PLC incinerator is newest layout for waste treatment, include medical waste, animal cremation and other solid waste. This equipment caliber structural for kinds of website, like hospital, diesel-fueled medical waste incinerator, dioxine emission control medical hospital incinerator, disposal of biological waste incinerator, do they create a mobile creamation furnance for pets, environmental division, animal cremation agencies, etc.. CLOVER Incinerator provide updated models with double combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.

Items Specification
Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC)
Main Product List Double Combustion Chamber
Smoke Filter Chamber
PLC Mode Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Infectious Waste Incinerator


Product Description

Principle of the Incinerator Gear is incineration/combustion/burn.

The main body is 1 combustion chamber (at least), Refractory lineup or firebrick, Insulation materials and also the outer plate. Ignition element is external oil or gas burner. The burner can be running until squander burnout but for a few waste such as plastic, paper (sometime, mix coal with waste before feeding), they can combustion itself following Ignition. During combustion, burner has small medical incenerator, small medical waste incinerators, small medical waste incineration, small medical waste incinerator makers, small medical waste incinerators in china, a fan itself for Oxygen supply and protect burner prevent heat damage from combustion room. And, there a external fan blow air into combustion chamber. The Exhaust gas blow off following combustion. 

Considering Environmental Protection requirements and rules, virtually all incinerator have secondary combustion chamber (after-burn, post-combustion), even when third combustion room. The secondary burner burn the Exhaust gas from primary combustion chamber, this technologies make sure adequate combustion, few black smoke and smell. 

The upgraded incinerator technology focus on Exhaust gas treatment to remove Hazardous material and other function from incinerator, such as heat recovery (waste to energy), save fuel price, PLC Automation operation. 

Item Customer Request Example
Application Scope  
 
 
 
Hospital, Pet Crematory, Slaughter House, Laboratories, School, Community, etc. if for animal/pet, indicate animal size like: cat, dog, cattle, etc
What kind of waste?  
____, _____%
____, _____%
____, _____%
 
 
Medical waste, dead animal, Municipal Waste, etc(detail name) or nature percent
if for animal/pet, indicate animal size like: cat, dog, cattle, etc
Quantity Request    
01.02.03^…unit
 
Budget    
$US Dollar.
 
 
Operating Time    
The staff work Hours per day.
Our incinerator can work up to around 18 hours per day.
Realization Date of project In ___ year  
Waste Output Capacity per Day?  
 
1000kgs Per Day^
Request waste burn rate   Capacity: 100kgs Per hour^
Request waste feed capacity   Capacity: 100kgs per feed^
Whether Natural Gas Supply Local?   Yes or No.
Local Power   If 380V and 220V valid?
Product Installation Destination  
 
Country or City name
DestinationSeaport name?   To check sea freight charge.
 
Customer    
End-Customer, Agent, Government.
 
Method of contract   Tender or Negotiation
Date of Tender limit    
How did you know our company?    
Other request or information  
 
 
 

In some Developed countries, some new waste treatment method such as High-temperature cooking, squander carbonization, crushing sterilization technology is instead of incineration technology.

Gas Incinerator


Basic Info.

Export Markets:Global

Additional Info.

Trademark:CLOVER
Packing:Container
Origin:Nanjing China
Production Capacity:1000 Sets Per Year

Product Description

 

How to Acquire Incinerator

1. 

Nanjing Clover Medical Technology Co., Ltd. save all rights to mend/update product info on site. The specifications are subject to change without any previous notice.

2. We accept company term: FOB/C&F/CIF word, by sea/train, full container or bulk products.  1. FOB (Free on Board), the price leave China port. 2. C&F (Cost and Freight), FOB price and freight price. 3. CIF (Cost and Freight and Insurance ), FOB price and insurance fee and freight price. Payment Term: By sea: 50% deposit T/T (bank transfer) beforehand, and 50% equilibrium T/T before shipping day. By Train: 100% T/T in advance.

4. Shipping Document & Packing: Generally, We provide (1)Bill of Lading (Way Bill), what's sample…(2)Commercial Invoice, (3)Packing List ONLY. If any further documents/certification and tag print/words on packing material or documents which ask by importer or local traditions, whatever happen in China or oversea, should inform seller beforehand and charge as real price. By way of example, Fumigation Certification, embassy certification, BV/SGS…review, certification of initial (C/O), Form A, etc.. Buyer must to inform seller beforehand and pay these price. Seller save rights to postpone/cancel shipping and price on pet incinerationcost pet cremation equipementprices of animal incineratorsprices of pet crematorium chinaprices on pet cremation incentorators,ask lost price cause this event.  In case the importer local traditions arrest/request penalty or other situation caused by buyer error, Clover Medical save all right to ask compensation/litigation.  Thanks for your cooperation.

5.  The major time is mostly 3-6 weeks, depending upon the products and volume. Guarantee: One year for the equipment. We provide spare parts for maintenance, free charge within the first year and also the delivery cost is on the purchaser. Insurance: Bear all risks of loss of or damage to the goods in the time they’ve passed the boat 's rail at the named port of shipment.  We proposal apply All Hazards insurance under every contract. When purchaser pick goods at local site, must inspect carefully. If any damage happened under insurance coverage, buyer should inform insurer and Clover Medical Limitedimmediately.  We’ll provide necessary assistance.

 

 

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Clover's Social Media