Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Incinerator Double Chambered 300kg/Hr
Basic Info.
Product Description
Items | Specification | |||
YD Model | YD-30 / YD-50 / YD-100 / YD-150 / YD-200 / YD-300 / YD-500 / YD-600 | |||
Main Product List | Primary Combustion Chamber | |||
Secondary Combustion Chamber | ||||
Mix Combustion Chamber | ||||
Smoke Filter Chamber | ||||
Incinerator Common Control Case | ||||
Stainless Steel Chimney | ||||
Italy oil/gas burner: 02 units | ||||
Oil Tank (if oil fuel) |
Nanjing Clover Medical Technology Co., Ltd..
Containerized Mobile Incinerator Version CA50
Waste Burner
(Containerized Mobile Heater)
Ability: Normal 50 kgs per human resources
Style |
CA50 |
Inside Dimensions |
100 x 80 x 70 centimeters |
Main Product Listing |
Main Burning Chamber |
Added Burning Chamber |
|
Smoke Filter Chamber |
|
Heater Control Situation |
|
Smokeshaft:5.0 Meters *( upgrade to Stainless-steel, cost-free rate) |
|
Italy oil/gas heater: 02 systems |
|
Oil Container (if oil gas): 200Liters |
|
ISO 20′ ′ ′ ′ Container( Shipment with Burner) |

Variation |
CA50 |
Waste Treatment |
Waste Incineration Treatment |
Feed Capacity |
Regular 100 kgs per feed |
Burning Price |
Regular 50 kgs per hr |
Burning Time per Feed |
Criterion 2 hour |
Control Setting |
PLC( Programmable Logic Controller Incinerator) |
Voltage |
220V |
Power |
0.7 Kw |
Fuel |
Diesel oil |
Burner |
Italy Heater |
Feed Mode |
Guidebook |
Temperature Level Screen |
Digital Present |
Gas intake (Oil) |
Normal 16.6 Kgs/Hour |
Inner Dimensions |
100x80x70cm (Key Chamber) |
External Capacities |
230 x 130 x 155cm (main body) |
Waste combustion chamber |
560Liters |
Blog Post Combustion Chamber |
280Liters |
Oil Container Capacity |
200 Litres |
Door Opening |
70 x 50cm |
Smokeshaft |
5.0 M |
Gross Weight |
4500kgs |
Chamber Item |
Firebrick, Refractory Concrete |
Max. Warmth Worth |
166,000 Kcal/Hr. |
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
2020-02-15
Animal body parts,other biomedical waste,organs dung
51.No Features $_pecific tions
1 (Incinerator)
Type of waste for disposal Animal body parts,other biomedical waste,organs dung, bedding materials,plant p缸ts and food itemsι
Incinerators for conversion of waste to fine,white sterile
ash with no visible smoke or odour
2. Load capacity 300 – 4∞Kg (maximum)
3. Bum capacity 100 Kgjhr (minimum)
4 Fuel Diesel (LDOjHSD)
5. Type of Bumer operation Automatic diesel fired
6. Primary chamber Solid hearth
Dense refractory concrete lining
Operating temeeralure of 850 土 50 deg C or more
7. Secondary chamber Slid heath
Dense refractory concrete lining
Opera恤19 temperature of 1∞o deg C or more
8. Temperature control Digital temperature control and display
Temperature monitoring and thermostatic control
9. Power supply 220V for control Box
10 Size Compact design preferred
11. Opening lid Large top open归g lid (Approx . 700 mm x 500mm) for
easy loading
12. Fuel tank 100-150 L
13. Civil works, installation and
comnuss!Onmg lndusive of civil works (brick wall incinerator house
with a shutter door,CGI sheet roofing) according to 由e
model of the incinerator.
lnstallation and commissioning of the incinerators including hiring of heavy machineries requ让ed at the time of instalIation .
Electric power supply line to light incinerator house as well as to control box of the incinerator
Onsite demonstrationjperformance test and adequate training of staff on the use of incinerators.
Warranty of one year from the date of commissioning. Separate Annual Maintenance Contract would be drawn with the supplier at a later stage.
14. Catalogue Catalogue containing detail pictures and spec迁ications
of the quoted incinerator must be included in the
bidding document
medical waste incinerators china
- Ensure flame contact with all gases is achieved. –yes
- Ensure residence time is not less than two (2) seconds. –yes
- Ensure the gas temperature as measured against the inside wall in the secondary chamber & not in the flame
zone, is not less than 1100oC.—1000-1200 oC
- Ensure the oxygen content of the emitted gases is not less than 11%.–yes
- Ensure both primary and the combustion temperatures are maintained until all waste has been completely
combusted–yes
5 Particulate Removers A mechanical particulate collector must be incorporated after secondary combustion
chamber for removal of particulate pollutants entrained in the flue gas stream. The particulate collectors may include
any of the following or a combination thereof:
Cyclone separator
Electrostatic precipitators
Fabric filters— filter brick
6 Chimney / Stack 1. The chimney should have a minimum height of 10 meters above ground level and clear the
highest point of the building by not less than 3 meters for all roofs. The topography and height of adjacent buildings
within 50 meters radius should be taken into account.—6 meter already, can plus 4 meters, free cost
- If possible the chimney should be visible to the operator from the feeding area.—according to local site
- The addition of dilution air after combustion in order to achieve the requirement of these guidelines is
unacceptable.
- The minimum exit velocity should be 10 m/s and at least twice the surrounding wind speed (Efflux velocity =
wind speed x 2) whichever is higher to ensure no down washing of exiting gases. .–yes
- Point for the measurement of emissions shall be provided. .–yes
7 Instrumentation Instrument for determining the inside wall temperature and not burner flame temperature must be
provided for both primary and secondary chambers.–yes
- An audible and visible alarm must be installed to warn the operator when the secondary temperature drops to
below the required temperature.
Capacity Not less than 500Kg/hr.
Operation 24hr-7days/week continuous operation.
Combustion chamber 2 combustion chamber.
Temp. First combustion chamber 800-1000 C.
Secandry combustion chamber 1000-1200 C, with the possibility to be upgraded to 1400
Little Capacity Incineratorsmall 20 Kg/Hour Medical Waste Inc
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste can use in this gear? A: This gear to medical waste, pet animal, Municipal waste, reside squander. Prohibit any volatile and radiation substance, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001. The animal/pet combustion rate around 2/3 of average power.
Clover incinerator use time daily to 24 hours. Between every feed/combustion time, you will find approximately 0.5-1 hours cooling time plus time to get feeding squander. Actual combustion time daily is about 16 hours. The lifetime of incinerator involving 5-10 year based on use.
Generally, we proposition little lab, little clinic use capacity under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output around 2kgs per individuals per day. If there are 200 sickbed at the hospital, that's mean you need one incinerator capacity around 400kgs per day, switch to power per hour is approximately 30-40 kgs per hour. According the performance time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. *The best way to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Meeting and Testing A: We supply all files and incinerators simple to installation and functionality. Client can send individuals visit our factory to find out installation and operation. Generally, we don’t send engineer to neighborhood site or even request. The dispatch cost is extra based on order. The next combustion chamber: 1000-1200 centi level.
Q: Incinerator Control Mode A: Default Control mode is common control case. PLC mode based on model and order.
Q: Operation and maintenance costs A: Operation cost based on fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD per year maintenance according version, use situation.
One person can service 02 unit incinerators. Incinerators italy for health care waste, incinerators health care waste, incinirator, industrial incinerators china, insenorator, klarge garden incinerator, laboratory animal incinerator auction, The team should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and know threat of medical waste to protect employee self with essential protection component.
One person can service 02 unit incinerators. Incinerators italy for medical waste, incinerators medical waste, incinirator, industrial incinerators china, insenorator, klarge garden incinerator, lab animal incinerator auction, The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |