Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Hospital Waste Management
Hospital Waste Management as well as Competitive prices as Pakistan is a competitive market. We have a complete setup with Office, Customer Relations, Import / Export, Biomedical Department, Application Support Department & Project Designing Department.Description Minimum Requirements
Design standard Multiple chamber incinerator to the design of EPA standards, Air pollution control
Description of the Chimney Top mounted, self supporting
Incinerator performance 150kg/hr
Refuse Hospital waste and carcasses
Recommended Temperatures Minimum 1000⁰C
Dimensions:
Length
Width
Height
Extra width for burners At least 3000mm
Loading door opening Minimum 700mm x 600mm
Hearth area 5.00square meters
Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume At least 3 cubic meters
Mixing chamber volume At least 1 cubic meters
Settling chamber volume At least 3 cubic meters
Weight excluding chimney 15, 000kg at manufacture
Firing tools supplied Hoe, Poker and rakeMaterial of construction Case – 5mm mild steel.
Bracing – Heavy angle and channel.
Hearth – 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Ashing door – High grade cast iron.
Loading door – 5mm mild steel lined with 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Refractory concrete:
Alumina content of refractory
Refractory thickness
Minimum 49%
At least 127mm.
Insulation to walls 1000⁰C Castable insulation
Chimney stack:
Chimney
Height from base 3.5 mm mild steel
9 meters above ground level and clear the highest point of the building by not less than 3 meters
At least 560mm
At least 750Kg
Controls:
Draught
Air supply
Electric
Barometric indicator, door operated draught limiter
Built-in forced heated air ducts, primary and secondary (intensifier)
Control panel – Circuit breakers, main switch, timer, pilot lights, 2 set point pyrometer and one set point pyrometer.
Electricity supply required 415 Volts Three phase.
Auxiliary fuel Electrically operated only
Emission Multiple chamber design with inbuilt emission control
Paint: Case and stack 400⁰C Heat Resistant Grey
Temperature of case 100⁰C
animal waste incinerator manufacturer
Technical specification for burning machine,animal waste incinerator manufacturer
1.Two systems are required to be installed in the south of the Kingdom of Saudi Arabia. The two systems will be used by custom authority to burn different kinds of drugs. All need equipment must be provided.
2.Warrantee: booth systems must be provided with 3 years warrantee from the date of acceptance. All needed spare parts, preventative maintenance repair and corrective maintenance must be included in the cost and provided to the customer.
3.All needed electric and water connections must be provided.
4.Both systems must be of high quality and must be environmental friendly.
5.The capacity of each system should be up to 100 kg/hr.
6.The system must have automatic feeding.
7.Each system must consists of two burning rooms, one primary room for burning the drug and another room for burning the gases that emit as a result of primary burning.
8.The oven must be made of steel that is rust resistance and with thickness not less than 6 mm.
9.Each system must be of high efficient in burning different kinds of drugs, and should have 99.9% efficiency for burning organic materials.
10.Waste products should not exceed 5%.
11.System must have automatic ignition system.
12.System should use diesel (HSD) as fuel and should not consume more than 8 to 10 lt/hr .
13.Each system should be provided with fuel tank of size adequate to operate the system for one full day.
14.The temperature in the primary room should be 850 C ± 50 C. the system should also be capable to operate up to 1050 C ± 50 C. the system should be capable of continues operation and should be provided with cement layer insulator with adequate thickness.
15.Oven should be provided with heat insulator to allow easy operation.
16.Gas should remain in the secondary room for not more than 1.5 second.
17.The primary burning room should have at least 2 burners.
18.The secondary burning room should have one burner.
19. Each system should have doors for ash, exit for air to the chimney and windows to allow looking inside and for maintenance.
20.Each system should have filtering system for gas processing with 2 tanks using ordinary water. Each water tank should have capacity of 1000 lt and should be fixed to the system and provided with water level indicator.
21.Each system should have special technology for separating waist products and humidity after gas processing.
22.Each system should have cooling capability after operation.
23.Each system m should be provided with exhaust pipe with 250 mm diameter and 10 m high. The base of the exhaust system should be 1000 mm. The exhaust pipe should be 6 mm and should be provide with heat insulator. The exhaust system should be provided with pressure indicator. It should also provide with ladder and Lightning Arrestor.
24.Electric power: should be 220 volt, 3 phase, 60 Hz, and the motor should not be less than 15 HP.
25.Each system should be provided with control panel and indicators and needed safety equipment and alarm systems. The control panel should show at least temperature in both the primary and secondary rooms and injectors of the filters and load.
26.Each system should be provided with alarm system for any breakdown or defect of any component of the system.
27.The following personal protective tools must be provide:
a.Heat resistant garments for 20 persons.
b.Heat resistant goggles for 20 persons.
28.All components of each system should be painted with silver color that is heat resistant.
pet incinerator deisel
and forced air exhaust stacks (or chimneys).
The charging system shall consist of, as a minimum, a hopper for top feeding and mechanically operated hydraulic
charging ram or augur. To prevent warpage or excessive thermal expansion, a charger cooling system using either
air or water shall be provided.
Primary combustion chamber shall be either the rotary- or stationary fixed-hearth (or kiln) type incinerator. Burner
and combustion air controls shall be fully automatic comprising of, as a minimum, electronic ignition and all
necessary interlocks and safety devices to provide safe operation. The chamber and burner shall be designed to
maintain a minimum combustion temperature of at least 700 to 870 C (1300 to 1600 F), but shall not to exceed 980
C (1800 F). The ash-removal system shall consist of the automatic continuous removal of the ash into an ashquench
pit where cooled by water and removed by conveyor.
Medical Waste Incinerator
Basic Info.
Additional Info.
Product Description
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
2nd. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Average 10kgs per hour incinerator for small hospital

Equipment Technical Specifications |
|
Model |
YD-10C |
Picture |
|
Feed Capacity |
Average 40 kgs per feed |
Burning Rate |
Average 10 kgs per hour |
Burning Time per Feed |
3.0 -5.0hours |
Voltage |
220V |
Power |
0.50Kw |
Fuel |
Natural Gas or Diesel oil |
Burner |
Italy Burner |
Feed Mode |
Manual |
Fuel consumption (Oil) |
4.4-9.4 Kgs/Hour |
Fuel consumption (Gas) |
5.3-11.2m3/Hour |
External Dimensions |
170 x 140 x 160cm (mainbody) |
Internal Dimensions |
55 x 55 x 65cm(Primary Chamber) |
Waste combustion chamber |
200Liters |
Post Combustion Chamber |
140Liters |
Oil Tank Capacity |
50 Liters |
Door Opening |
38 x 48cm |
Chimney |
5.0M |
Gross Weight |
1800kgs |
Chamber Material |
Refractory Concrete |
Max. Heat Value |
94,000Kcal/Hr. |
Operation Technical Specifications |
|
Solid Chamber temperature |
8000C -10000C |
Gas Chamber temperature |
10000C -12000C |
Chamber Anti-Rate
|
13500C |
Residency time |
2.0 Sec. |
Burning efficiency |
>98% |
Waste Lower Calorific Power |
3000Kcal |
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]