Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Latest Product

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

an incinerator for food waste and polythene waste management

an incinerator for food waste and polythene waste management. as per our requirements we would like the YD 15C small incinerator.Mixed Biomedical waste Incinerator.Contract period:To be decided by the supplier
Payment terms:100% prepayment through bank TT after signing of contract.

Please confirm your willingness to execute this contract project by sending brochure and your price quotation for the below specification to enable us submit it to the firm incharge of the contract for their study and approval.

Type of Waste: Mixed Biomedical waste.THE INCINERATOR AS REQUESTED BY OUR CLIENT SHALL BE SEMI AUTOMATIC WITH:
WASTE BUCKET/TANK – ABOUT 2000KG
CAPACITY OF FEEDING: ABOUT 600-800Kg AT A TIME.
BURNING AT ABOUT 150/165-200 IN 60MINS
THE BURNER SHALL USE DIESEL/OIL
WITH CHIMNEY, ELECTRIC PANNELS,ELECTRIC MOTORS,ETC.
MATERIALS FOR DISPOSAL: SHARP MEDICAL WASTES.

1. Waste burning capacity of unit: 100-125 kgs / hr.
2. Mode of waste handling : Autoloading– DFDV + Bucket elevator
3. Type of fuel : LDO / HSD
4. Type of Burner operation : Automatic
5. Expected fuel consumption: 30-35 kgs/hr **(depending upon overall
mix of the waste, moisture
content, etc.) after preheat.
6. Connected electrical load : Approx. 7-8 KW (AC 3 phase,220V, 50 Hz).
7. Overall space requirement : 9 m (L) X 8 m (W) X 6 m (H) Each unit
without stack

Burners temperature controlled (TIC – Thermocouple) and work on ON –
OFF basis. The frequency on ON – OFF will depend upon the nature of
waste, moisture content, calorific value, etc. and shall vary from waste to
waste. The fuel consumption also depends upon the frequency of the door
opening and method of operation of the incinerator. We have mentioned
approx. expected fuel consumption figures.

The Incineration System comprises of :

I. Main Incinerator with
A. Primary & Secondary Chamber Modules duly refractory lined, piped & wired.
B. Bucket elevator + DFDV mechanism for autoloading and Deashing
mechanism
II i. 1 No. fully automatic Fuel Oil burner for primary chamber.
ii. 1 No. fully automatic Fuel Oil burner for secondary chamber.
III. Centrifugal forced draft fan assembly complete with motor drive, duct and
dampers, etc. mounted on the common skid of the unit to provide :
Combustion air.

Eductor air.
IV. Eductor Assembly for :
Cooling of exhaust gases from 900 – 1000 0 C to around 350 0 C .
Keeping the entire system under negative pressure to avoid hot gases / dust
particles rushing out of charging door.
V. Electrical Control Panel along with safeties, and Audio / Visual
indicators and
/ or alarms for efficient and safe operation of the system.
VI. Electrical wiring of the unit.
VII. Oil tank of 1000 ltrs capacity mounted on the skid
VIII. Operating tools and tackles comprising of – rake, hoe, shovel (I No. each).
IX. Chimney of  2.5 Mtr height.

medi burn 30 contraband incinerator


air retention for at least 2 seconds at a temperature of less than 850C, the combustion

In order to achieve the proper effect.

? must be a two-chamber incinerators, primary and secondary

Fuel stoves

? The waste products to reduce the initial volume

Possible to minimize (approximately 5% sterile ash

Form).

Purpose: Top Loader incinerator of general, medical and dry waste to comply with the requirements of the Air Quality

Act, 2004 (Act No 39 of 2004)

 

1     Design standard  Retort type, multiple

2     Description of chimney     Top mounted, self supporting, unlined

3     Stack height from base     At least 11 meter (depends on height above sea level)

4     Incineration performance Capacity       750 kg/hour

5    Temperature Primary  Minimum 850 degree Celsius

6     Temperature Secondary    Minimum 1000 degree Celsius

7     Dimensions (minimum)(cm)

Length

Width

Height

210

180

210

8     Loading door opening (m)       200

9     Description of grate/hearth      Full

10   Primary chamber volume (minimum)     1.05 cubic meters

11   Tools included    Poker, hoe, rake

12   Materials of construction (minimum)

Case

Bracing

Hearth

 

 

 

Ashing door

Loading door

 

?     Chamber Volume: 0.1m3

?     Load method: Front

?     Fuel options: Diesel  or Natural gas

?     Typical fuel: Liquid propane gas: 6 liters per hour

?     Consumption: Natural gas: 6 liters per hour


TS(PLC) Model Medical Incinerator

DSC00453_看图王

* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime.
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 100kgs per hour.
* PLC Control Plane for Intelligent operation.
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.

Tel:  +86-25-8461 0201

medical incinerators



* scientific burners, The insulation of the burning chamber require to be made up of refractory bricks, having a.
high web content of aluminium and likewise protects bricks in order to make sure a minimum temperature level on.
the outdoors sheet metal.
* Structure of the refractory;

? Refractory concrete:.
?. Density: ≥ 100 mm.
?. Nature: 42% of Al203.
? Safeguard in coarse panels:.
?. Thickness: ≥ 75 mm.
? Nature: Calcium silicate.
* Heating unit of lighting of waste, with gas, typical mono-bloc casting leading diving fire, lights and also security of electronic ignition, long-term ventilation, electromagnetic sluice entrance of regulation as well as also separating valve.
* Plate of burning in Carborundum, preventing the taking care of glass and slags.

18. A chamber of message combustion of gases.
* A heater of burning of gases,.
* A device of shot of air permitting a total recombustion of gases,.
* A gadget of air inlet of cooling of waste gases,.
* A sheath of emptying of the gases burnt.
* Carcass in strong sheet steel with assistance of web link.
* Structure of the refractory;.
? Refractory concrete:.
? Density: ≥ 150 mm.
?

* Framework of the refractory;



Diesel Fuel Incinerator


Basic Info.

Model NO.:medical incinerator design
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste can utilize in this equipment?  A: This equipment for medical waste, pet animal, Municipal waste, reside waste. Prohibit any volatile and radiation substance, liquid gas and waste waste.  GB18484-2001. 

Q: Remedy capacity  A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion speed around 2/3 of average capacity. 

Clover incinerator utilize time per day up to 24 hours. Between every feed/combustion time, there are approximately 0.5-1 hours cooling time and time to get feeding waste. Actual combustion time daily is about 16 hours. The life of incinerator involving 5-10 year based on utilize. 

Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please compute the waste output around 2kgs per individuals each day. If there are 200 sickbed at the clinic, that's imply you need one incinerator capacity around 400kgs each day, change to capacity per hour is approximately 30-40 kgs per hour. According the operation time every day, waste material, budget, growth, etc, you can use capacity from 30-50 kgs each hour incinerator.  *How to compute Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Assembly and Testing  A: We supply all files and incinerators simple to installation and functionality. Client can send individuals come to our factory to find out installation and operation. Diesel oil fired medical waste incenerator, double chamber incinerator, ecological incinerator, encenerator, farm incinerator, Generally, We do not send engineer to local site or even request. The dispatch price is extra based on order.  The next combustion chamber: 1000-1200 centi level. 

Q: Incinerator Control Mode  A: Default Control mode is common control instance. PLC mode based on model and order. 

Q: Operation and maintenance costs  A: Operation price based on fuel consumption rate and power/staff, etc. 

Annual approximately $500-$1000USD annually maintenance according version, utilize situation. 

One individual can service 02 device incinerators. The staff should have fundamental electrician understanding to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and understand threat of medical waste to protect worker self with necessary protection component. 

Q: The Residency time in secondary combustion chamber  A: 02 sec.

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Clover's Social Media