Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Latest Product

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

arrangement of waste non multiple-use burner system



installment of waste non reusable system in airport.Incinerator with oil heater
Capability 2 ton/day, Oil storage tank 300 l Oil pump 0.4 Kw, Heating unit 0.2 Kw.
Variation: YD Collection.
– Diesel heater. It will definitely have usually paper, cardboard and likewise food, though also it will absolutely blaze medical waste. The heater will have the ability to deal with natural and also polluted products.
Smokeshaft External Size: not above 400mm.
Fan Power: require to not go beyond 1.1 kw.
Voltage: 220V.
Oil Consumption: Required to not surpass 14kg/hr.
Feeding Door Dimension: not less than 1000x1300mm.
Incineration Temparature: 800 Level or above.
Discharge:.
CO- Have to not exceed 100mg/m3.
SO2- Should not exceed 400mg/m3.
HF( Hydrogen Flouride)- Must not surpass 9mg/m3.
NO2- Must Not exceed 500mg/m3.
Given that it will certainly deal with organic and damaging waste, temperature level has to reach a minimum of 1100 degrees for a minimum of 2 Second. The flue gas cleansing equipment maust go to the very the very least two-field electrostatic precipitator/ESP, dust

– Diesel burner. It will absolutely have typically paper, cardboard and additionally food, though similarly it will definitely incinerate clinical waste. The heater will certainly have the capability to deal with natural and also polluted products. Since it will treat unsafe and natural waste, temperature level has to reach a minimum of 1100 levels for a minimum of 2 2nd.

–– 25Kg/h. It will certainly have generally paper, cardboard and also food, though likewise it will certainly incinerate medical waste. So the burner will have the ability to deal with organic and contaminated materials.

–– Spare components for one year.Burning Capacity: 400kg/ Human Resources (Optimum Combustion time is 6 times/ Day).
Smokeshaft External Size: not greater than 400mm.
Fan Power: need to not surpass 1.1 kw.
Voltage: 220V.
Oil Intake: Need to not surpass 14kg/hr.
Feeding Door Size: not less than 1000x1300mm.
Incineration Temparature: 800 Degree or above.
Emission:.
CO- Have to not surpass 100mg/m3.
SO2- Must not surpass 400mg/m3.
HF( Hydrogen Flouride)- Should not go beyond 9mg/m3.
NO2- Must Not exceed 500mg/m3.
Smoke Dirt: Have to Not surpass 100mg/m3

–– The design need to prevent any type of launch of contaminating substances right into dirt, surface area water and groundwater.

–– Burning area needs to get to a minimum of 860 degrees under the most damaging conditions with at least 6% oxygen. Since it will treat harmful and organic waste, temperature level has to reach a minimum of 1100 degrees for a minimum of 2 2nd.

–– Flue gases must be cooled down to 200 levels or reduced prior to flue gas therapy. The flue gas cleaning equipment maust go to the very least two-field electrostatic precipitator/ESP, dust << 30mgNm3.

–– Thermal efficiency not less than 85%.

–– It must be geared up with filter to minimize as well as include toxins from natural and clinical waste.

–– Easy to operate for virtually inexperienced employees.



Small Scale Incinerator 10kgs Feb Hour


Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

Essential Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long lifetime. *based on sequence * High fever, long lifetime of incinerator.  * Free or minimal installation onsite.  * High burn rate, from 10kgs to 500kgs per hourto 6ton per day.  * PLC Control Plane. *based on order  * New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock.

Items Specification
YDC Model YD-10C / YD-20C / YD-30C / YD-50C
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

TECHNICAL SPECIFICATION FOR MEDICAL WASTE INCINERATOR (50 – 60kg/hr)

COMPLIANCE (YES, NO or COMMENT)
Item

Description

Medical Waste Incinerator, 50 to 60

Kg/hr

Item Quantity 5 No.
Support Health Sector Support Project
Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals
1.     General Description

Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment. The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006). The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.   The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour. It shall be constructed from mild or aluminized steel lined with refractory material.

 
2.   Composition

2.1     Main unit

2.2   Accessories

 
3.   Performance specifications  
3.1 Main unit    
3.1.1 Application For incineration, general and pathological
3.1.2 Capacity 50 – 60 kg/h burn rate
3.1.3

 

Type Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit
3.1.4 Operating time Minimum 8 hours daily
3.1.5 Operating temperature From 850 0C to 1200 0C, Automatic controlled
3.1.6 Residual Ash 5 to 10%
   3.2       Primary Chamber
3.2.1

 

Construction Constructed from heavy duty mild or aluminized steel Or

equal and approved equivalent

3.2.2

 

Insulation material Refractory material lining similar or equal to calcium

Silicate and hot face combination of heavy duty brickwork

3.2.3

 

Internal Construction Fixed hearth type complete with gratings, concave bottom

and charging door, lined with refractory material

3.2.4

 

Charging Door Suitable for manual loading of wastes and with smooth

Dear seal equivalent of Ceramic seals with hinges.

3.2.5 Door Lock Automatic, Electric type
3.2.6

 

Ash removal door Provided, for removing resultant bottom ash leftovers                             from the Primary chamber
3.2.7 Gratings Provided
3.2.8 Loading Manual loading of waste
3.2.9

 

Primary Burner Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure, Diesel fired fuel injector type and Flange mounted
3.2.10

 

Blower Provided. For supplying excess combustion air through the distribution system with speed control system
3.2.11 Temperature Minimum exit 850 0C
3.2.12 Observation port To be provided with protective glass type
3.3       Secondary chamber
3.3.1

 

Construction Constructed from heavy duty mild or aluminized steel or equal and approved equivalent
3.3.2

 

Insulation Refractory material lining
3.3.3

 

Combustion Temperatures Above 850 0C, controlled electronically
3.3.4

 

Gas residue or retention Time > 2 second at minimum 850 0C  
3.3.5

 

Secondary Burner Provided, Diesel fired, fully automatic, with fuel, temperature and speed controls, With ignition system,                                                                   Flame detector, Air fan, Complete with safety features, flame failure Diesel fired fuel injector type.                                                                   Flange mounted
3.3.6 Ejector Provided, Venturi type, for cooling the flue gases
3.3.7

 

Combustion Air Fan Provided for supplying combustion and creating a negative drift and turbulences
3.3.8 Temperature Maximum 1600 0C
   3.4       Chimney
3.4.1

 

Construction Constructed from heavy duty mild or aluminized steel   or equal and approved equivalent                                                                   Refractory material lining
3.4.2 Length 10 m above ground
3.4.3 Bore about 350mm diameter
3.4.5 Discharge temperatures About 850 0C
3.4.6 Emissions To comply with standards in section 9 of third schedule of the waste management regulations, 2006.
   3.5         Electrical System
3.3.5

 

Control unit Fully automatic with microprocessor based control                                                                       unit (PLC) automating all operations of the                                                                       incinerator. Capable of monitoring all incinerator parameters With large LCD or similar for display of all progress

Parameters i.e. temperature of primary and secondary chambers, turbulence and time

With status lamp

With user of defined and differed programmed operating cycles for different type of loads/conditions

With safety interlocks, display of errors and visible and audio alarms.

System for continuous emission monitoring

3.5.2

 

Isolator switch Supply and install isolator switch 240V, 100A for the                                                                     incinerator unit, including all necessary cables 10m
3.5.3

 

Distribution Board Supply and install distribution board. 100 A, complete with MCBs suitable for the rating of the incinerator unit and associated equipment. Wiring     to be done according IEE regulations.
3.5.4

 

Wiring Make provisions for wiring the isolator switch, Distribution Board control unit to Incinerator and all associated equipment inside to incinerator room.                                                                         Working length 20m. Wiring to be done using PVC Sheath cable on steel conduits and trucking and in accordance with IEE regulations
3.6     Fuel System Supply and install storage fuel tank inside the incinerator room at an elevated position (about 1.5 m above the floor)
3.6.1

 

Fuel Tank Tank capacity, 400 liters, constructed from preferable suitable metallic material or high temperature resistance material
Fuel type Diesel
3.6.2

 

Fuel Lines Supply and install fuel lines, complete with fuel filters, pump, sight glass, fuel level and all other safety devices and connect from fuel tank to incinerator.

Working length , 20m

Fuel pipe material; Special copper pipes or similar                                                                         and approved materials

4               Physical characteristics  
4.1 Main unit Floor mounted, stand alone, fixed hearth type
Dimensions About 1.2 x 2.2m (WxD)
5   Operating environment    
5.1 Power Requirements 240V,A/C 50Hz, single phase, with PE
Ambient temperature 10 0C to 40 0C
Relatively humidity 40% to 90%
6. Accessories  
Rack, 2 m long 1 piece
6.1 Waste cart, stainless steel 1 piece
7 Spare parts
7.1 Burner 1 set
7.2 Fuel Filters 6 sets
7.3

 

All other spare parts                     required for replacement during and after 12 months of operations. 2 pieces of each
8               Quality Standards  
8.2

 

Manufacturing standards NEMA Kenya Act, 1999

Legal Notice No.121 of 29th September 1999 on waste Management Regulations

EU waste incinerator Directive- EC 76/2000

BS 3316

WHO Emission Standards

World Bank Emission Standards

or any other internationally recognized standards

Conformity to standards CE marked or any other internationally recognized documents
9         Local back up service
9.1 Available Should be available locally
9.2 Capacity to service equipment Manufacturer/Agent shall have adequate facilities, spare parts, qualified and skilled technical staff to offer comprehensive maintenance   service and spare parts sales for the lifespan of the incinerator
10         Delivery point  
10.1 KEMSA For inspection and verification
10.2

 

Moi Voi, Makindu

Maragua, Eldama Ravine and Isiolo Hospitals

For installation, testing, NEMA Certification and commissioning
11 Pre installation works

 

Provide for foundation plinth, necessary plumbing works, Fuel piping works, Elevated Diesel oil storage tank, electrical works including cabling, trunking and switch gears required to install the incinerator and all its accessories to required IEE standards
12 Installation and testing Complete installation and set up of the incinerator at designated as per manufacturer’s instructions

Provide fuel and test run the incinerator for 3 hours daily for 7 days

13          Training  
13.1

 

User training On site user training on operation and daily up keep
13.2

 

Maintenance training On-site maintenance training on Preventive Maintenance, repair and trouble shooting
14 Technical Documentations  
14.1 User manuals 2 sets
14.2 Service manuals 2 sets
14.3 Drawings 2 sets
15         Commissioning  
15.1 Testing and Commissioning of the machine to the satisfaction of the user
16 Warranty
16.1 Equipment Minimum of one year after commissioning on all parts.
16.2 Equipment system Nil
17.   Maintenance contract
17.2 Comprehensive preventive & repair           service Provided a 12 months comprehensive preventive and repair service contract inclusive of spare parts and material from date of commissioning

Made-in-Vietnam waste incinerator shows its power


He started working on this kind of incinerator some years ago, supported by the notion that his incinerator may help decrease the negative impact caused by countless tons of medical waste.

In 2009, after successfully producing an incinerator, he filed a patent registration because of his’hazardous waste incinerator’ into the Ministry of Science and Technology and obtained the patent in 2012.

Nang’s incinerator is a method that comprises a comprehensive combustion chamber which could burn off waste in an uninterrupted process. The incinerator utilizes nano technologies that disintegrates hazardous smoke, dust and frog.

The product is thought to have outstanding features which let it operate more efficiently than products of the exact same kind.

Nang said that his waste incineration process is movable. The machine may work nicely if users have a small water tank and may treat the water.

He also said that all the incinerators available in Vietnam don’t have the pressure equilibrium like his. The incinerator can burn waste, eject fire rather than oil into burning substances. At the center of the combustion chamber, the temperature may reach 1,800oC.

With Nang’s incinerator, it does not take much time to burn waste. The oil is lasting, and there is not any technical problem with oil tubes.

When the incinerator runs with gas, then it is going to need VND5,000 only to burn 1 kilo or waste. Meanwhile, the incinerators out of US, Japan and UK would have VND70,000-80,000 worth of gasoline to burn a kilo of waste.

The outstanding characteristic of the made-in-Vietnam incinerator is that it may treat many types of waste, including national garbage and medical waste.

Manager of the Bac Kan Science and Technology Department Do Tuan Khiem said the incinerator is the Right choice for localities with moderate waste capacity. The machine is highly efficient and fuel-saving, which can be big advantage in Vietnam’s conditions.

From: http://english.vietnamnet.vn/fms/science-it/145663/made-in-vietnam-waste-incinerator-shows-its-power.html

If the incinerator runs with diesel, it will need VND5,000 only to burn one kilo or waste. Meanwhile, the incinerators from US, Japan and UK would consume VND70,000-80,000 worth of fuel to burn a kilo of waste.

The outstanding feature of the made-in-Vietnam incinerator is that it can treat many kinds of waste, including domestic garbage and medical waste.

Director of the Bac Kan Science and Technology Department Do Tuan Khiem said the incinerator is a suitable choice for localities with moderate waste capacity. The machine is highly efficient and fuel-saving, which is big advantage in Vietnam’s conditions.

From: http://english.vietnamnet.vn/fms/science-it/145663/made-in-vietnam-waste-incinerator-shows-its-power.html


Animal Carcass Incinerators


Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

2011 year is an important foundation for us. We reach to developed country market and stabilize old clients. Clover Incinerator has grown to be one of the famous and biggest incinerator provider throughout the world. 

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to sequence * High temperature, long life of incinerator.  * Free or minimum installation onsite.  * High speed, from 10kgs to 500kgs per hourto 6ton daily.  * PLC Control Plane. *according to order  New Design for pet animal cremation enterprise.  * One year warranty on incinerator and components in stock.

Item Customer Request Example
Application Scope  
 
 
 
Hospital, Pet Crematory, Slaughter House, Laboratories, School, Community, etc. if for animal/pet, indicate animal size like: cat, dog, cattle, etc
What kind of waste?  
____, _____%
____, _____%
____, _____%
 
 
Medical waste, dead animal, Municipal Waste, etc(detail name) or nature percent
if for animal/pet, indicate animal size like: cat, dog, cattle, etc
Quantity Request    
01.02.03^…unit
 
Budget    
$US Dollar.
 
 
Operating Time    
The staff work Hours per day.
Our incinerator can work up to around 18 hours per day.
Realization Date of project In ___ year  
Waste Output Capacity per Day?  
 
1000kgs Per Day^
Request waste burn rate   Capacity: 100kgs Per hour^
Request waste feed capacity   Capacity: 100kgs per feed^
Whether Natural Gas Supply Local?   Yes or No.
Local Power   If 380V and 220V valid?
Product Installation Destination  
 
Country or City name
DestinationSeaport name?   To check sea freight charge.
 
Customer    
End-Customer, Agent, Government.
 
Method of contract   Tender or Negotiation
Date of Tender limit    
How did you know our company?    
Other request or information  
 
 
 

Clover's Social Media