Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Latest Product

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

hospital incinerator

Supply, installation and testing of medical waste incinerator with a capacity of 75 kg / hr gas (LPG) complete with all accessories and consequently with the chimney in accordance with the technical specifications and conditions of public health
make a room for the incinerator that  accommodate three incinerators as in item 3.1.1 and attached to the  incinerator room   waste store that accommodate waste for a period of seven days and all the constructions of reinforced concrete with  preparingg  incinerator building  and store with all the work of wiring, electrical and lighting systems, water supply and sanitation
supply incinerator building and the waste warehouse with   a fire extinguish sprinkler system depends on the source of the water from network of teh general site , as well as a fire alarm system contains sensors for heat, smoke and  this system is linked with the hospital fire alarm systems
Supply, installation and testing of the ventilation system of the  incinerator room and the warehouse with  fans ROOF TOP EXHAUET FANS providing them with filters with high efficiency (HEPA FILTER ride to pull fans with taking the air change rate of 5 times per hour with streams and air required grilles
Supply, installation, testing separate conditioning unit for  waste repository DUCTED SPLIT UNITES and capacity sufficient to maintain the internal temperature at 14 degrees Celsius in summer and winter
Supply, installation, testing  of the cooling store of  insulated  prefabricated walls   inside the waste  room with a capacity of   35 cubic meters to save the medical waste at a temperature of zero Celsius till  burning  including the  cooling unit and all accessories
HAZARDOUS    wood
play wood
petroleum residual waste
hydraulic hose system
calcium hydroxide bags
bags or wooden boxes containing cyanide
medical waste
filters
pharmaceuticals
NO HAZARDOUS    sawdust
plastic
plastic and textil awnings
wood
plastic tubs
rubber
sanitary waste
EPPs
plastic bags
construction residual
contaminated rags or towels
plastic or packing of food
polyestirene dishes, glasses, spoon, fork, etc.Capacity incinerator medical waste to high combustion temperature
With a smokeless device to protect the environment and with two combustion chambers equipped with gas burners or oil
-incinerator to burn large volume pieces of 70 cm
deviation: Automatic Control System
-destructive capacity from 20 to 30 kgs
First-room / Temperature = 900 ° C combustion
2nd bedroom / Temperature = 1200 ° c afterburner

Solid Waste Incineration


Product Description

Incinerator is a incineration gear, direct fire waste by gasoline fuel or oi gas. As different circumscription, incinerator can be termed many words as below: 

Therapy ability: Small scale incinerator, big scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators  Incinerator gas: Gas incinerator, oil incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator manufacturer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.  Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)  Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

YDC incinerator is newest design for waste treatment, include health care waste, animal cremation and other solid waste. This gear quality structural for kinds of site, such as incinerators for animal waste sweden, incinerators for hospital wastes, incinerators for pets purchase, incinerators for poultry out of china, incinerators available kenya, hospital, environmental division, animal cremation bureaus, etc.. CLOVER Incinerator provide updated versions with dual combustion chamber, mix combustion chamber and smoke filter chamber using refractory lines, and the combustion chamber temperature up to 1200 deg C.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

china medical burner



the complying with containerized burners. (Kitchen location as well as accommodations and grey water and black water plant eliminating waste) we need burner is each function various are done in one heater we require notified.
WASTE HEATERS SUGGESTIONS

china clinical burner Capability
? Disposal of both non-hazardous as well as infected products streams (per waste inventory).
?
Design/Specifications.
? Incinerators must have an added burning chamber with a minimum temperature selection of 900c.
? Liquid waste streams shall be blazed by a correct liquid shot system.
? The heaters will definitely be mounted with aesthetic alarm systems to indicate procedures of reduced temperature level in the secondary chamber.
Running Atmosphere as well as likewise Ambient Troubles

The Incinerators plan shall be developed to operate under the list below problems:.
? Ordinary Daily Max/Min June Temperature Level Level, 21-39 ° C.? Ordinary Daily Max/Min January Temperature Level Level, 2-12 ° C.
Medical waste heater,.
approx. 0.4 cubic metres,.
gas/ keys power operated,.
thermostatic temperature degree control,.
programmable cycle



biomedical waste monitoring



HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.

We supply single burning chamber, dual combustion chambers, 3 combustion chambers as well as multi-combustion chambers waste incinerators for laboratory, center, hospital, clinical facility, hygiene medical waste damage with medical non reusable, biological waste, medical plastic waste, contaminated materials, red bag waste, needle disposal, gauze as well as plasters, secured sharp containers, pathological waste, trace-chemotherapeutic wastes, and so on pet dog cremations, trash incinerator, incinerator available, cremation oven



Pets Crematorium


Basic Info.

Style:Crematorium
Material:Crematorium
Species:Dog
Export Markets:Global

Additional Info.

Trademark:CLOVER
Origin:Nanjing Clover

Product Description

The necessary circular Medical Waste Incinerator will be quoted in accordance with Technical Specifications supplied below:  1) A self-contained, diesel fuel, medical waste incinerator with a minimum burn rate capacity of 100 kg/day. 

2) A medical waste incinerator shall be especially designed by the manufacturer to eliminate Bio-Hazard medical wastes. 

3) At a minimum the unit shall be sized to incinerate 2.0 kg/exam-room/24-hrs when being operated continuously for 12 hours every day, but no less than 100kg/day total. 

4) The Incinerator shall be batch fed. 

5) The incinerator gas tank shall satisfy the following requirements:  A) The tank shall be installed above ground and according to all of the large medical waste incinerator, large mobile incinerator, large scale animal incinerator, large scale incinerators for medical waste disposal, fuel tank requirements at Section 1015 including secondary containment.  B) The tank shall be sized to maintain a 14 day supply of diesel fuel 

6) Manufacturer has to supply the following power calculations and all supporting data for your incinerator: 

– The daily waste stream rate (kg/day or lbs/day)  Minimum incinerator burn capabilities – Minimum cure period for your refractory to prevent breaking into the refractory  A comprehensive list of the maintenance components A minimum of 500 lbs of refractory for repairs  A minimum of 1 gallon of hydraulic oil 

7) The contractor shall provide 3 pricing options:  Option 1: To Quote only for the Full System  Option 2: To Quote the purchase price of Full System, and also the Installation  Option 3: To give training to proper relevant staff according to the 'Operations and Maintenance.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Clover's Social Media