Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
steps of medical waste administration
With years worth of experience in this field, our clinical array of incinerators are made to provide for the cost-effective needs of little centers to the a lot more demanding and specialized demands of large healthcare facilities in their waste administration processes.incinerators in india, medical facility burners, incinco incinerators,500 litre burner, gas incineration, utilized burners
HICLOVER is currently supplying a full variety of medical waste burners, made to supply efficient waste destruction, utilizing ideal available modern technologies and also eco pleasant procedure. Due to the additional chamber with its 2 2nd retention duration, our medical burner variety is well matched to process clinical waste.
HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste.
Medical Incinerator Specification

Operation 24hr-7days/week continuous operation.
Combustion chamber 2 combustion chamber.
Temp. First combustion chamber 800-1000 C.
Secandry combustion chamber 1000-1200 C, with the possibility to be upgraded to 1400 C.
Combustion Efficiency 99.99%
Retention time Of the flow gases not less than 2 Sec in the hot portion.
Excess Oxygen concentration Of primary combustion chamber 3-6% max.

Refractory The chambers should be lined with high thermal insulating refractory bricks with suitable thickness and with highly temp.
resistance. Not less than 1400 C for the first combustion chamber, and not less than 1600 C for the secandry combustion chamber, and at the
same time prevent the Temp. of the outside body of the chamber not higher than 70 C.
Doors Should be lined with the same bricks, and the edges lined with special suitable insulating material to prevent any gas escaping, and
the doors should be kept under negative pressure during the operation.
Air Emission Control System With high destruction and removal efficiency (DRE). Not less than 99.9999 as per KEPA.
Wet System If the system equiped with a CEMS washing the flow gas with water, then it should be manufactured from suitable anti
corrossion materials, and equiped with pH meter to measure and neutralize the water. It should be able to use the water in closed recycled
circuit many times before treating/ discharging into the sewage system in compliance with KEPARS.
Chemical dosing It should be equiped with suitable autochemical dosing system to control the pH for the water of the wet scrubber system
including sensors.
Chimney It should be suitable with the capacity and the technical specifications, with height not less than 12m from ground level. With easy
opennable sampling point equal about 3 inch, and the optimum sampling locations is at least 8D downstream direction and 2D upstream from any
flow disturbancies.
Sampling point Should be equiped with a platform located down the sampling point by a distance not less than 1 m, and equiped with suitable
stairs from ground to the port with comfortable slope.
Ash Removal It should be auto ash removal system.
Fuel It should be dual system, such as diesel and natural gas.
Feeding System Should be auto feeding system into primary chamber.
Control Room Should be equiped with a control panel shows Temp. of the combustion burners, gas monitoring, digital Temp. indecation for the
primary/secondary chambers, digital Temp. indication for the gases…etc. it should be also Auto operation, burnures on/off auto lamps switch,
auto start/stop for air emission control system, auto gas continuous monitoring system reading and print out of gas emission parameters…etc.
Cooling System The primary chamber should be provided with auto cooling systemthrough nozzles to permit direct cooling if the Temp. will be
heigher than 1100 C.
Inter-lock system The incinerator should be equiped with inter-lock system to prevent feeding the waste to the primary chamber if the
combustion Temp. less than 500 C.
Flue treatment and cleaning To consist a combined system (wet/dry), using water, lime, active carbon and ceramic filters.
Quenching system/Heat exchanger Should be made and manufactured from anti corrosion and acid attack materials such as stainless steel 316 or
equivalent.
Noise Level Not more than 85 dBA during normal operation.
Inaddition The desigh should insure that responsive fail-safe control systems are used.
The incinerator should be installed inside closed suitable building with good aeration and ventilation system. The building has
facilities for off-loading of wastes from transport vehicles. Auto cleaning system for trucks and waste containers, and cool storage
area…etc.
The quotation should included list of original spare parts for 7 years.
The quotation should include supervising, starting up and training of the operators and ministry of health engineers inside/outside
Kuwait.
Detailed drawings, catalogs should be included.
incinerator 500kg per
Composition of the refractory lining:
* Insulation:
– Operating temperature: 1000 ° C max
– Nature: Calcium Silicate
– Thickness: 80 mm
* Refractory:
– Operating temperature: 1650 ° C max
– Nature: Refractory bricks with 42 alumina
– Thickness: 110mm
Burner combustion:
– The combustion chamber is equipped with a burner to line to ensure correct temperature for the total destruction of
waste combustion;
– Automatic monobloc burner and flame plunge equipped with an electronic ignition system and permanent ventilation.
Air fan:
– A primary air and secondary air fan provides the necessary oxygen delivery
– There is a motor operated valve that controls the flow according to the combustion.
– The pressure of the fan is 500 mm CE to pierce the mass of waste during combustion.
The Medical Waste Disposal Incinerator units shall be of Dual or Multiple Chamber type that thermally degrades
combustible medical wastes of varying heat content using a two-stage or multiple stages combustion processes. That is
first stage of thermal waste degradation in the primary chamber and second stage of smoke burning (flue gas treatment)
in the secondary chamber. The waste burning process per cycle shall be fully automatic from start to finish. The waste
incinerator unit shall consist of a primary chamber, secondary chamber, stack, combustion air blower, burners and
controls as the main components.
medical waste incinerator
medical waste incinerator: medical waste and general waste
Capacity to burn waste: 400 — 500 kg/hr
Fuel: Diesel
Fuel Consumption: 10 litres/hr maximum
Incineration temperature: 950 – 1300 °c
Casing: thick (min 5 mm) Stainless steel casing and fully
insulated to withstand sea humidity
Voltage: 220/240 V or 380/415V
Frequency: 50 Hz
Feeding: automatic
Ash 1 leftovers removal: Automatic
Fuel gas filtration system: Yes
Warranty: 12 months
Staff training: Operator & Maintenance staff
Operation and service manuals: 3 sets each
Especifica??es Gerais 6 mm plate steel sheel construction
11cm 1400°C refractory Liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000°C
400°C silicone Based finish paint
alloy temperature sensor
factory wired and tested
Capacity 20kg/hr
primary Chamber 1607 L
Hearth area 1.36 aq.m
Secondary Chamber 694L
Primary burner (oil) 420.00btu
Secondary burner (oil) 900,000btu
Secondary combustion 1/6 hp
Exhaust stack 46cm x 6m
Electrical service 220/50
System weight 5,700kg
Dimension “D” 152cm
Doad port height e 60x60cm
Ash port height e 36x36cm
General Specifications 6mm plate steel sheel construction
11cm 1400 ° C refractory liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000 ° C
400 ° C silicone based paint finish
alloy temperature sensor
factory wired and tested
Capacity 20kg/hr
primary Chamber 1607 L
Hearth area 1:36 aq.m
Secondary Chamber 694L
Primary burner (oil) 420.00btu
Secondary burner (oil) 900,000 btu
Secondary combustion 1/6 hp
Exhaust stack 46cm x 6m
Electrical service 220/50
System weight 5.700 kg
Dimension “D” 152cm
Doad port height and 60x60cm
Ash port height and 36x36cm
medical, hospital, veterinary and industrial wastes by medical waste incinerator Process.
So, we’re interested with your Incinerator plants, and we’d like to get quotation and key features description of different capacities of your Incinerator plants, concerning: small models (5 – 25 kg/hr); medium models (25-50 kg/hr) and big models (50-100 kg/hr) and plus.