Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Incenorators for Pets
Basic Info.
Additional Info.
Product Description
Nanjing Clover Medical Technology Co., Ltd..
Key Features: * All models with Dual combustion room. * Stainless Steel chimney/stack, long life. *based on order * High fever, long life of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 500kgs per hourto 6ton daily. * PLC Control Plane. *based on order New Design for pet animal cremation business. * One year guarantee on incinerator and components in stock.
Application Scope: 1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation
Nanjing Clover Medical Technology Co., Ltd. Tel: +86-25-84610201 Fax: +86-25-84610406
pet crematory
The temperature is over the minimum and under the maximum required temperature (e.g 1150?C) of the thermal
reactor (partial load).
When switching off, only the solenoid valve for the fuel supply closes, the burner fan stays on to cool and protect the
burner head.
The reactor burner shall be modulating burner with pre-ventilation working on the principle of an oil pressure atomizer
with return nozzle for diesel oil, consisting of:
– Fan housing with high-powered fan and cover
– Electric motor
– Oil pressure pump with built-in oil pressure controller
– Burner nozzle rod with return nozzle and baffle plate
– Coupled control with servomotor, rate controller, regulating segment and air valves
– Electromagnetic shut-off dampers
– Burner tube with flame pot, burner connection and insulation flange
– Electrical high voltage ignition with ignition transformer and ignition electrodes
In the control panel:
– Oil firing sequence control automation relay.
capacity – 50 Kg
Burn rate – 20 Kg/h
maximum Temperature – 1000C
Operating Energy – Diesel
Ignition method –
Combustion chambers – 2
Insulation – refractory Lining
No of burners – 2
Loading Method – Front load with safety latch
Chimney – Heavy duty stainless steel
Control – Burner control
Thermostat control
Timer control
Fan timer control
Instrumentation -4 Digit temperature display
Ash removal – Separate ash removal door
Fuel consumption per Kg –
Automatic & simple to operate control pannel –
3 mm steel casing & fully insulation
Dense refractory concrete lining rated to 1400 degree to C
safety chute for easy loading –
SS Flue as standard –
Heat recovery option –
Easy onsite Installation –
animal waste incinerator
secondary chamber
1000 degree
chimney
standard
shredder
separately
Autoclave or microwaves
separately
temperature monitor
attached outside of machine
operating
Fuel and electric
During the start and end incineration operations at the waste incineration plant the temperature shall be maintained
at 850 °C, while it shall be 1100 °C when incinerating dangerous waste containing halogenated organic substances with
content of chlorine or its compounds. The temperature shall be maintained at 1000 °C during incineration of medical
waste.
MUNICIPAL SOLID WASTE INCINERATORS
Municipal waste incinerator quantities and capacities shall be designed for 24-hour 7-day-a-week continuous operation.
Incinerators shall be capable of processing both wet and dry material and operating on either diesel fuel, JP-8 fuel,
or waste oil; see Plumbing for fuel storage system requirements. The following shall be provided as a minimum:
Reinforced concrete mounting foundations, feed or charging hoppers (or loaders), primary combustion chambers
with ash cleanout doors, secondary combustion chambers with ash cleanout doors, cyclone air filters (or separators),
incinerator manufacturers
GOODS: ONE INCINERATORS IN ACCORDANCE WITH THE | SUPPLIER’ | ||||||
REQUIREMENT | S | OWN | |||||
PROPOSED | |||||||
SPECIFICA | |||||||
TION/ | |||||||
CONFIRM | |||||||
ATION | |||||||
SPECS | |||||||
Height from base: 11m and if there are buildings within 30m of the | |||||||
incinerator, chimney must extend at least 3m above the apexes of all | |||||||
the roofs of such buildings | |||||||
Diameter of chimney at top: 430mm | |||||||
Weight of stack: ± 500kg | |||||||
case and stack be painted with 400 °C heat resistant black paint | |||||||
Burners | |||||||
1st chamber 850 oC -900oC | |||||||
2nd chamber 1000oC | |||||||
Variable speed combustion air blowers | |||||||
Primary chamber volume ±1.05 cubic metres | |||||||
Mixing chamber volume ±0.30 cubic meters | |||||||
Settling chamber volume ±0.89 cubic meters | |||||||
Weight excluding chimney ±6 400kg at manufacture | |||||||
Firing tools supplied: Hoe, poker and rake | |||||||
Dimensions | |||||||
Length ±2 125mm | |||||||
Width ±1 890mm | |||||||
Height ±2 125mm | |||||||
Extra width for burners | ±1 000mm | ||||||
Loading door opening 610mm×540mm | |||||||
Hearth area ±1.19 square metres | |||||||
Description of grate/hearth: A full hearth to be supplied to prevent | |||||||
contaminated liquids from flowing into ash pit without being | |||||||
incinerated | |||||||
Compliance with South African Atmospheric Pollution Prevention | |||||||
Act No. 45 of 1965 or equivalent air pollution standard | |||||||
Documents to be supplied : Operations and maintenance manual and | |||||||
standard operating procedures (SOPs) | |||||||
Emission controls: | |||||||
heated refractory screen | |||||||
Low velocity grit settling chamber | |||||||
Stainless steel arrester screen | |||||||
Refractory material: alumina content ≥49% and thickness average | |||||||
102mm | |||||||
Bake out: to be done over 2-3 days | |||||||
Materials of construction | |||||||
Case: 5mm mild steel | |||||||
Bracing: heavy angle and channel | |||||||
Hearth: 1550 °C | |||||||
Ashing door: high grade cast iron | |||||||
Loading door 5mm mild steel lined with 1550 °C castable general | |||||||
purpose high strength, high abrasion resistant monolithic refractory | |||||||
concrete | |||||||
36 |
medical waste incineration monitoring
All kindly animals owners wish their wonderful pet dog or feline be in heaven after they leave us. We comprehend the special bond in between pet dog and also owner and also believe that it must never ever be forgotten. Shedding a pet can be ravaging and also we developed our business so family members can remember their pet dogs forever.incineraters, pet dog cremation business, cannabis waste elimination, local waste burner, veolia incineratorhospital waste incinerator, hazardous waste incineration, gas incinerator, incineration garbage disposal
The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world.