Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
tiny range scientific waste burner
Hazardous as well as likewise hazardous wastes,
Medical pharmaceutical along with pleasant fluids Wastes
Residential trash
Electric as well as electronic wastes
Hazardous waste
Generally, all kind of wastes and also rubbishes
Ability 50-60Kg/ h
Combustion sustaining materials
Coal oil, diesel oil
Temperature degree inside
800-10000C
1000-12000C
Burning performance
> 98%
Power intake
1.3 KW
Sound
< 78dB
Index of let smoke as well as waste gas
Ringelman’s smoke index < level 1
Smoke focus
Oil
45.5
( mg/m3 ).
Gas.
25.5
( mg/m3 )
SO.
Oil.
0.176.
Gas.
0.065
NOX.
Oil.
0.031.
Gas.
0.038
H2S.
Oil.
0.016.
Gas.
0.008
CO
.
Oil. 8.32.
Gas.
35.64
tiny scale clinical waste burner Demands.
Additionally eruptive as well as fireproof products not confessed
Refine way.
2 shedding storage rooms (wetness drying, warm dirt elimination)
Burning/ Heater.
Top quality made in Italy
Blower.
High quality made in China
Control Electrical.
High quality made in China
Ability 50 Kg/h
Performance Voltage.
220 V
Power.
1000 W
Applied For.
200 beds
Input Style.
Hands-on
Medical Burner, 24 kg/hr.
Clinical Heater, 24 kg/hr including panel board, regulates in addition to accessories.
Heating unit entry.
Chimney.
Blower.
Combustion heater
Medical Incinerator, 12 kg/hr.
Medical Heater, 12 kg/hr including panel board, controls as well as also devices.
Heater portal.
Smokeshaft.
Blower.
Burning burner
Medical Incinerator, 6 kg/hr.
Clinical Heater, 6 kg/hr including panel board, regulates in addition to tools.
Heater entrance.
Chimney.
Blower.
Burning heating unit
china heater distributor and also exporter
Primary Burning Chamber
Waste Charging Door: Given with refractory cellular lining with securing gaskets
Ash Eliminated Door: Supplied with refractory cellular lining with sealing gaskets
Exterior Body MOC: Mild Steel, 5mm
Main Chamber: Stainless-steel
Running Temperature degree:800. ± 50 ◦ C.
Insulation: Insulation Block.
Burner Kind: Kanthal Al High Quality.
Power Use: 75 KW (Initial Lots ).
Electric Supply:3 Phase 440 Volt.
Control board.
MOC: Mild Steel Power Coated.
No. of Temperature: Controllers: 2 Nos.
Information: The Control Panel will certainly be offered with contract as relays, switches, indicators and more. Operative on 3 phase.
I.D.Fan.
Kind: Centrifugal Kind.
MOC: Mild Steel.
Capacity:2 HP/3Phase.
Make of Electric Motor: Kirloskar/ Havells/Crompton.
Burning Air Follower.
Type: Centrifugal Kind.
Capability: 1HP/3Phase.
Make from Electric Motor: Kirloskar/ Havells/Crompton
Process Engineering Design of Pathological Waste Incinerator
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste can utilize within this equipment? A: This equipment for medical waste, pet creature, Municipal waste, live squander. Prohibit any explosive and radiation substance, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t mean any waste material. The animal/pet combustion rate around 2/3 of average power.
Clover incinerator utilize time per day up to 24 hours. Between every feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding squander. Actual combustion time per day is about 16 hours. The lifetime of incinerator involving 5-10 year based on usage.
Ordinarily, we proposition small laboratory, small clinic use capability under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output capacity around 2kgs per people every day. If there are 200 sickbed at the clinic, that's mean you need one incinerator capability around 400kgs per day, change to power per hour is around 30-40 kgs per hour. According the performance time every day, waste material, funding, development, etc, you can use capacity from 30-50 kgs each hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Assembly and Testing A: We supply all files and incinerators easy to setup and functionality. Customer can send people visit our factory to learn operation and installation. Generally, We do not send engineer to local site if not request. The dispatch price is extra based on order.
Q: Combustion Temperature A: The very first combustion chamber: 800-1000 centi level. The next combustion chamber: 1000-1200 centi level. PLC mode based on model and order.
Q: Operation and maintenance costs A: Operation price based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according version, utilize situation.
One person can service 02 unit incinerators. Medical waste diesel incinerator, medical waste incinerators, mobile incinerator china, nanjing clover medical technology co., ltd., pet crematorium equipment, The staff must have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on functionality consumer guider, and understand risk of medical waste to safeguard worker self with necessary protection component.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
500kg/day burn capacity incinerator
in acinerator with 300 kg/ hour by double filter wet and dry.Pet Dead Body Incinerator upto 80 kg ,gas operated is prefered. animal waste incinerator with capacity about 40Kgs. We will use this product to burn the animal corpses in normal way (not sick aninal).Could you please forward me quotation for incinerator that is suitable for service Town with a population of 200,000 people including other general town waste to burn. Technical specifications data sheet
List and quantities of consumables required per month
List and cost of all the spares required annually
List and costs of all the spares required in 5 yrs
List and costs of all the spares required in 10 yrs
2 incinerators one with 500kg/day burn capacity another one with 1000kg/day burn capacity
1 x Electrode
1 x Fuel Filter
1 x Photocell
1 x Flexible pipe
1 x Nozzle
1 x Control Box
medical waste incinerator china
medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: –
· Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste
· Waste density: 125 to 350Kg/M3
· Waste CV: 4000 KCAL/kg
· Moisture content: 10-25%
· Estimated ash residue: 5-10%
· Nominal capacity: 30Kg/hour batch load
· Secondary chamber: 0.5 second @ 850oC
· Compact laboratory style
· Two combustion chambers
· Ecologically friendly
· Up to 50kg of waste / hour
· To be used for animals