Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Design TS30 oil ended waste tiny burner 30kgs
Model TS30 oil fired waste small incinerator 30kgs/hr.![]()
Items/Model
TS30( PLC)
Picture
![]()
![]()
Melt Price
Typical 20-30 kg/hour
Feed Capacity
Normal 60kg per feeding
Control Establishing
PLC( Programmable Thinking Controller Incinerator)
Burning Chamber
330L
Inner Measurements
75x75x60cm
Secondary Chamber
180L
Smoke Filter Chamber
Yes
Feed Establishing
Manual Feeding
Voltage
220V
Power
0.5 Kw
Oil Usage (kg/hour)
Average 13.3
Gas Consumption (N.G, m3n/Hour)
Typical 16
Gas Intake (L.P.G, m3n/Hour)
Average 11.7
Temperature Level Screen
Four Digital Present
Temperature Defense
Yes
Oil Storage Tank
100L or Even More( Optional)
Feed Door
55x50cm
Smokeshaft
5Meter or More( Optional)
Chimney Kind
Stainless-steel
1st. Chamber Temperature
800 ℃–– – – -1000 ℃
second. Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Gross Weight
4000kg
Outdoors Dimensions
175x120x140cm
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
2020-02-14
3 Chamber Incinerator
Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature sensor points with complete internal fans.
Secondary Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times.
Third Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time.
Integrated dual flu gas washer:

Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters.
Chimney:
Heavy duty 5mm or more stainless steel casing mild steel casing.
Stack cap/spark arrestors.
Control Panel:
a.Temperature Monitoring with 4 digit display.
b.Thermostat control device for burner (fuel saver)
c.Temperature control 0-12 hours.
d.Integral fan timer control
hog incinerator
(B) Features and Specifications of the Steam Boiler: Features of the Boiler:
- It must be an Electrical boiler
- Splash proof electric enclosure and switches
- Door Isolator to main electric enclosure
- Alarm lights and Safety/protection against excel pressure
- Level control on feedback water tank
Technical Specification of the Boiler:
- Output: between: 90-110 kg/h (F&A 100 deg C)
- Working pressure : between 7-10 bar
- Boiler water content : between 80-100 litre
- Feed water take content : between 60-80 litre
- Power consumption : between 60-75Kw
- Number of Heating Elements: 3-4 nos.
- Electrical requirements: 400Vac, 50 Hz, 3 ph
(C) Technical Specifications of Tab washer Features:
- Fully automatic and manual modes.
- Metal construction, SA 240/304
- Sensors to maximize both machine efficiency and operator safety.
- Must use Re-circulating cold wash water to minimize water consumption and operating costs
- Disinfects all bin surfaces
- Uses Powerful blow dryer to remove excess surface water
- Must be compliant with all North American and EU regulations
Specification:
- Tub washer able to wash bins of a suitable size, the norm being 38 g
- Must have an water reservoir of capacity minimum: 225 litre
- Perfectly suited for hospitals and clinics by processing up to min. 300 bins per hour.
- Time to wash and dry one bin after loading approximately 30 secs.
- Bins loading on wash station at a time — approximately 12 nos.
- Overall length : approx 30.0 feet
- Overall height : approx 8.0 feet
- Overall width: between 3.0-3.5 feet
- Height to Conveyer from ground: approx 3 feet.
Drive of the Tub washer:
- Motor driven
- Moto: Horsepower: approx 4.0 HP
- Power: 220 vac, 1ph or 400 VAC, 3 ph or the suit customer needs
Bins to be included:
- 200 nos with different color (based on the requirement of the hospital)
Big General waste heater Burn Price as much as 250kg per hr
![]()
2020-03-22
11000kg
External Dimensions
400x210x300cm( with no smokeshaft)
2020-03-22
Items/Model
TS300( PLC)
Concept
Waste Incineration Treatment
Melt Price
Requirement 250 kg/hour
Control Placing
PLC( Programmable Logic Controller Incinerator)
Burning Chamber
2000L
Inside Dimensions
170x120x100cm
2nd Chamber
1000L
Smoke Filter Chamber
Yes
Feed Establishing
Handbook
Voltage
220V
Electricity
2.5 Kw
Oil Infection (kg/hour)
Typical 28( DO)
Gas Consumption (m3/hour)
***
Infection Level Degree Monitor
Digital Present
Temperature Defense
Yes
Oil Storage Container
1000L
Feed Door
80x60cm
Smokeshaft
10Meter
Smokeshaft Kind
Stainless Steel
1st.
Gross Weight
11000kg
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
External Dimensions
400x210x300cm( with no smokeshaft)
Medical Incinerator 150 Kgs Per Hour
Product Description
Items/Model | YD-30 | YD-50 | YD-100 | YD-150 |
Burning Rate (kgs/Hour) | 30 kgs/Hr. | 50 kgs/Hr. | 100 kgs/Hr. | 150 kgs/Hr. |
Feed Capacity (kgs) | 60 kgs | 150 kgs | 200 kgs | 300 kgs |
Equipment Weight | 2300 kgs | 4000 kgs | 4300 kgs | 7000 kgs |
Primary Chamber (Liters) | 360 | 900 | 1200 | 1500 |
Secondary Chamber (Liters) | 200 | 200 | 500 | 500 |
External Dimensions (cm) | 145x90x175 | 200x160x230 | 220x180x360 | 240x170x380 |
Internal Dimensions (cm) | 100x60x60 | 120x90x85 | 130x100x90 | 150x100x96 |
Oil Tank(Liters) | 200 | 300 | 300 | 500 |
Door Opening (cm) | 48 x 60 | 62 x 80 | 55 x 80 | 59 x 81 |
Chimney (M) | 5 | 5 | 10 | 10 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES |