Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Mobile Small Range Medical Waste Incinerator with Cart or Wheel

Model | YD-30 | ||||||
Picture | ![]() |
||||||
Burning Rate | average 30 kgs/hour | ||||||
Feed Capacity | average 40 kgs | ||||||
Paimary Combustion Chamber | 200 Liters | ||||||
Secondary Combustion Chamber | 100 Liters | ||||||
Mix Combustion Chamber | Yes | ||||||
Feed Mode | Manual | ||||||
Voltage | 220V | ||||||
Power | 0.59Kw | ||||||
Fuel Type | Diesel Oil | ||||||
Burner | Italy Original | ||||||
Oil Consumption (Diesel Oil) | average 13.3 kg/hour | ||||||
Gas Consumption (Natural Gas) | *** | ||||||
Internal Dimensions | 80 x 50 x 50cm (paimary chamber) | ||||||
External Dimensions | 125 x 90 x 180cm (without chimney) | ||||||
Temperature Monitor | Yes | ||||||
Oil Tank Capacity(if oil fuel) | 60 Liters | ||||||
Door Opening | 40 x 40cm | ||||||
Chimney Length | 1.0 Meters | ||||||
Chimney Type | Stainless Steel | ||||||
Equipment Gross Weight | 1500/1700 kgs |
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
2020-06-30
a DUCK ranch heater
a DUCK farm burner, we require to acquire a tool size incinerator for organic waste, a lot more specific DUCKS.an animal dog crematorium in ireland.Equipment Double chamber medical infectious waste burner Capacity 10-30 kg per hr Features of waste
The list listed below average features are thought about *:
residence heating well worth above 2000 kcal/kg (8370 kJ/kg); material of combustible matter over 60%; internet material of non flammable solids listed below 5%; product of non-combustible fines detailed below 20%; moisture material listed below 30% by weight
Burning efficiency: The medica waste burner will certainly be capable of minimizing waste to ash not exceeding 10% of the total flammable prices. The scientific waste burner will be installed outdoors. All burner parts will certainly be appropriate for however not restricted to outside shaded arrangement, consisting of electrical electric motors, be resistent to rust, dampness and also relevant climate aspects.
Outside installment. The clinical waste incinerator will be mounted outdoors. All incinerator components will be suitable for however not restricted to outdoor shaded setup, including electrical motors, be resistent to corrosion, wetness and also related climate aspects.
can you please onward me some info. an ideal Burner for Incineration of oil, plastic hazardous waste, sludge waste, harmful filters etc.
laboratory incinerator
the entire carcass of animals ( cattle , horses ,
Sheep, pigs , etc.) , as well as biologically hazardous waste
Products in the fuel stove .
? Opening Doors – the closure and fixation automated system ,
Which are managed remotely by the operator .
? designed to work in long mode and fast
Action ( Quick Start EP – i)
? Fully mobile – mounted on wheeled chassis
Even during the operation . Incinerators must be provided
As standard equipment a special truck
air retention for at least 2 seconds at a temperature of less than 850C, the combustion
In order to achieve the proper effect.
? must be a two-chamber incinerators, primary and secondary
Fuel stoves
? The waste products to reduce the initial volume
Possible to minimize (approximately 5% sterile ash
Form).
Incinerators should be provided in the fuel tank (diesel )
? The minimum capacity of the animal carcass incinerator
The destruction of 1000 kg / hour. Incinerator capacity is calculated
8MJ/kg- material and 60 % humidity.
? It must be possible to use the incinerator +40
C to – 15 0C laboratory incinerator
Temperature and 5% – 95% – of moisture conditions.
? PLC controller and a built-in temperature panelita complete
Automatic control, a control computer, which is stored
Information on the variation of temperature with respect to time and
Graphic images.
? must have fuel with automatic control and malfunction
Detection system.
?the ability to pre- warm-up , body waste burning on and off
Consistency is independent of the first and secondary chambers.
? ensuring the incinerator with electricity , it
Must be installed on the generator.
? clean the incinerator should be simple tools ,
Without using any additional equipment
pet incinerators
The panel and parts hereof shall have the following characteristics:
Finish
All metal parts shall receive a treatment taking the prevailing environment conditions into account.
The top paint colour shall be the Manufacturer’s standard.
Auxiliary Wiring
All auxiliary wiring shall be carried out with wires having a minimum cross section area of
1.5 mm2.
Wiring is connected to terminals blocks in such a way that there is no more than two wires on each terminal.
Current wires from current transformers shall be not less than 6 mm2.
All wires shall be marked at each end for identification.
All markings shall be carried out in compliance with the corresponding circuit diagrams and wiring lists.
Cable Termination
Auxiliary wires will be terminated to numbered terminals.
Main circuit cables will be bolted to numbered bars.
Top Feeding Door Solid Waste Incinerators HICLOVER
HICLOVER Top Feeding Door Waste Incinerators▲▲▲Large Feeding Door▲▲▲Better for Animal Waste Cremation▲▲▲HICLOVER Brand Section***Primary Combustion Chamber***Secondary Combustion Chamber***Smoke Filter Chamber***Optional Wet Scrubber System(1 section or 3 sections)
Email: sales@hiclover.com
Email: hicloversales@gmail.comNanjing Clover Medical Technology Co.,Ltd.
Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter difficult Safty safe safer Incinerator Shape L/ I L Loading manual big door can be by Forklift Land occupation small big Ash door same with feeding door or alone alone market share Most-CHINA/USA/INDIA Few- UK/USA Dooring open type Manual Pry bar/Hydraulic pressure Dooring Open size small big Better for medical bag waste animal waste open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke
parts of an incineratorphysical method of disposing hazardous chemical wasteportable incinerators typesproper ways of waste disposal in the communityquestionnaire to ask about incinerators for collection of dataHICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator
2020-08-07