Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste may use in this gear? A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation material, liquid gas and waste waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion speed around 2/3 of ordinary power.
Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, you will find about 0.5-1 hours cooling time plus time to get feeding squander. The life of incinerator involving 5-10 year according to use.
Generally, we proposal little lab, little clinic use capability under 20 kgs per hour. If incinerator use in hospital, then please calculate the waste output around 2kgs per individuals per day. If there are 200 sickbed at the clinic, that's imply you need 1 incinerator capability around 400kgs per day, switch to power per hour is approximately 30-40 kgs per hour. According the performance time per day, waste material, budget, growth, etc, you may use capacity from 30-50 kgs each hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Assembly and Testing A: We provide all documents and incinerators easy to installation and operation. Customer can send individuals visit our factory to learn operation and installation. Generally, We do not send engineer to neighborhood website or even request. The dispatch cost is extra according to order. The second combustion chamber: 1000-1200 centi degree. PLC mode according to order and model.
Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD annually maintenance according model, use situation.
One person can service 02 device incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and know threat of medical waste to protect worker self with essential protection component.
Q: The Residency period in combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |