Incinerators


Basic Info.

Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator Maker in China.

Items/Model A1500 A2400 A4000 A5500
Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr.
Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs
Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 1500 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 240x170x380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 500 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Key Features:  * All versions with Dual combustion room.  *based on sequence * High fever, long life of incinerator.  * Free or minimal installation onsite.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton daily.  *based on order  * New Design for pet animal cremation business.  * One year guarantee on incinerator and components in stock.

Medical Incinerators Supplier in China



*** Primary combustion chamber & secondary combustion chamber
*** Smoke filter chamber(dry scrubber)
*** stainless steel chimney
*** PLC auto. control
*** Italy made oil or gas burner(diesel oil/natural gas/lpg)
*** temperature display and control
*** high temperature firebrick,etc
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-10



A MOBILE MEDICAL WASTE INCINERATORS



Key Product Checklist

Main Burning Chamber

Additional Combustion Chamber

Mix-Combustion Chamber

Smoke Filter Chamber

Incinerator Control Circumstance

Smokeshaft:5.0 Meters *( upgrade to Stainless Steel, cost-free cost)

Italy oil burner: 02 collections

Oil Storage Tank: 150Liters

Mobile Trailer for Incinerator

















Version

YD-50C

Burning Price (kgs/Hour)

Typical 20-50 kgs/hour

Feed Ability (kgs)

Typical 80 kgs/feeding

Instruments Weight

2500 kgs( Burner)

Primary Chamber (Liters)

400

2nd Chamber (Liters)

140

Outside Dimensions (centimeters)

180x160x200

Inner Dimensions (centimeters)

70x70x85

Oil Tank( Liters)

150

Door Opening (centimeters)

45×× × × 55

Chimney (M)

5

Smokeshaft Kind

Stainless Steel

Additional Chamber

YES

Mix-Combustion Chamber

YES

Smoke Filter Chamber

YES

Combustion Fuel

Oil

Residency Time

2.0 Sec.

Temperature Degree Keeping An Eye On

YES

1st.

800 ℃–– -1000 ℃

2nd. Chamber Temperature

1000 ℃ -1200 ℃

Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.



Incinerator Price for 50kg/Hr


Basic Info.

Model NO.:incinerator pet cremation prices
Export Markets:Global

Product Description

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *based on sequence * High fever, long life of incinerator.  * Free or minimal installation onsite.  * High speed, from 10kgs to 500kgs per hourto 6ton per day.  * PLC Control Plane. *based on order  * New Design for pet animal cremation business.  * One year warranty on incinerator and components in stock. 

Program Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Likewise biomedical and dangerous waste


is instilled and also full burning is achieved.

Solitary Chamber Excess Greater compared to an adequate Quantity of air (as high as 50 percent more than the amount

demands are figured out, partially, by precisely just how the land is designated under area government improvement plans (i.e. land usage

zoning).

Strong waste burners are crafted systems that are capable of frequently accomplishing melt temperature levels over of 1000oC

and likewise a holding time of in the very least one. The incineration of

additionally biomedical and unsafe waste and additionally sewer sludge requires specific devices, functional controls in addition to training that are

beyond the array of the present paper.

On the surface supplied gasoline in addition to electricity are needed for the heaters in addition to forced air ventilation. A correctly running double-

chamber managed air system will surely decrease problems with pet tourist attraction as the creation of foundation and also fly ash in addition to smoke

is decreased.

Area 2.3.2 is intended to provide the site visitor with a concise intro to replacements. It is not meant to give

information appropriate for the design, selection or procedure of an incineration system. Anyone taking into account the purchase of

that an incineration system must first contact the machine ’s provider or various other qualified people with experience in the

incineration of solid waste.

demands are figured out, partially, by precisely how the land is marked beneath area authorities growth plans (i.e. land usage

zoning).

Solid waste incinerators are crafted systems that are capable of consistently completing burn level levels over of 1000oC

and a holding period of in the very the very least one. The incineration of

additionally biomedical in addition to harmful waste as well as sewer sludge requires specific tools, functional controls in addition to training that are

beyond the assortment of the present paper. A correctly running double –

chamber managed air system will surely lower issues with animal visitor attraction since the creation of foundation and likewise fly ash in addition to smoke

has been reduced. Any sort of person considering the procurement of

that an incineration system need to first get in contact with the system’s provider or various other certified people with experience in the

incineration of strong waste.

is decreased. It is not meant to provide

information acceptable for the design, choice or functioning of an incineration system. Any person taking into consideration the purchase of

that an incineration system must first get in contact with the system’s provider or various other qualified people with experience at the

incineration of solid waste.

consistent residence heating worth close to the design aspect of the incinerator.

Establish feed dual-chamber handled air incinerators now run in a range of remote commercial areas in north west

Canada and Alaska. They are usually taken right into account to have the greatest feasible top high qualities of all of the heaters and also open

burning strategies pointed out, they require to be developed for the type and volume of waste to be discard. The highlights of the

type of incinerator are:

Set procedure permits better management of temperature level in addition to air during the shed procedure.{
(adsbygoogle = window.adsbygoogle || []).push({});|}{
(adsbygoogle = window.adsbygoogle || []).push({});|}
Air System of air needed) is infused into the lone thaw room to complete total burning of the waste.

Constant Feed An incineration procedure that remains in a constant shed cycle. A consistent feed|


Medical Waste Incinerators


Basic Info.

Model NO.:medical waste incinerators on sales
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste may utilize in this gear?  A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation substance, liquid waste and gas waste.  GB18484-2001. 

Q: Remedy capacity  A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t mean any waste material. The animal/pet combustion rate around 2/3 of ordinary capacity. 

Clover incinerator utilize time daily to 24 hours. Between every feed/combustion time, there are approximately 0.5-1 hours cooling time plus time to get feeding squander. Actual combustion time per day is about 16 hours. The life of incinerator involving 5-10 year according to utilize. 

Ordinarily, we proposition little lab, little clinic use capability under 20 kgs per hour. If incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the clinic, that's mean you need one incinerator capability around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the performance time per day, waste material, funding, development, etc, you may use capacity from 30-50 kgs per hour incinerator.  *How to calculate Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Meeting and Testing  A: We provide all documents and incinerators simple to setup and operation. Customer can send people come to our factory to learn operation and installation. Waste+incinerator+manufacturer, animal cremation, animal crematory equipment, animal incinerator price, animal incinerator maker, cheap incinerators, Ordinarily, We do not send engineer to local site or even request. The dispatch price is extra according to order. 

Q: Combustion Temperature  A: The first combustion chamber: 800-1000 centi level.  The second combustion chamber: 1000-1200 centi level. 

Q: Incinerator Control Mode  A: Default Control mode is common control case. PLC mode according to order and model. 

One individual can service 02 unit incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and understand threat of medical waste to protect worker self with necessary security element. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Crematorium Animal Equipment Diesel


Basic Info.

Model NO.:chinese industrial waste incineration
Export Markets:Global

Product Description

Key Word:  Small incinerators  Medical waste incinerator  Pet animal cremation incinerator  Incinerator manufacturers 

Incinerator is a incineration equipment, direct fire waste by gasoline fuel or oi fuel. As different circumscription, incinerator can be termed many words as below: 

Treatment ability: Small scale incinerator, big scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators  Incinerator fuel: Gas incinerator, petroleum incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer.  Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)  Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

Pyrolytic incineration specialized is conventional waste treatment solution for several years. All around the planet, in most nations, people anti incinerator because the incinerator will create a large Dioxin in the smoke. Dioxins can be released to the environment through forest fires, backyard burning of garbage, certain industrial activities, little waste incinerator, little waste incinerator manufacturers, small-scale medical incinerator, small-scale medical incinerators, smallest incinerator, and residue from past business burning of waste. Dioxins break down very slowly and past releases of dioxins from the natural and man-made resources still exist in the environment. Anyhow, we have to remind that, this is big scale incineration pant, normally greater than 30 ton daily. This is a societal issue, to analyze and indicate ways in different angles in the public, government, economic development, environmental protection, technology advancement, etc. 

So, why people still use incinerator?  To begin with, for the medical waste in the hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management.  Second, for human body, pet animal, in most nations and areas, we want to cremation them. This is the service in the procedure for society development, and ceremonies to commemorate the disappearance of existence. 

As previously two rationale although not only above, we still utilize incinerators. 

How you are able to find reasonable incinerator for your local site?  Incinerator is not a cheap equipment, normally the little scale model's cost around $5, 000USD per unit and big scale model's cost more than $50, 000USD each unit. So, before buy one unit incinerator, you have to make clear after things: A, burn out what? Incinerator is a incineration equipment, function is flame waste. So what kind of waste you want to cure?  B, little or big? This according to the waste output every day or the waste volume per feed time, like animal size.  Incinerator use gas or oil fuel, normally, gas fuel is cheaper than oil and the smoke cleaner than petroleum fuel model. However, some neighborhood site don't have gasoline distribution system.  And other technology items, such as electricity (220V, 380V), waste feed doorway kind, incinerator structure, etc. 

Once you clarify these, it is possible to go to find a local or international manufacturers, requesting prices, technical specifications and finally purchasing the ideal products. 

Wrote by Nicky

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES