Burners


dropped between 5000-10000 kg per hour.Mostly waste from oil storage tanks. Structure and construction, installment and also 6 months upkeep cost such as specifications.CMSD for Dual Chamber Rotating Klin Kind Incinerator (first Chamber temperatur less than 850 degree centrigrade & & & & next Chamber Temperature Level much less than 1200 c with exhaust pipe 100 meter long using discharge gas filtering system apparatus ), Hydroclave (Clinical) with anciliary gadgets operating standards: Temperature 250-275 level feren, Stress and anxiety 15-35PSI, Hygiene period 30 minus, Establish ability -463 kg. 2 Burners for a healthcare centre in VN. The anticipated capacity is roughly 1,000 kg every day.


Waste Clinic Incinerator


Basic Info.

Model NO.:united states animal incinerators for sale
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

A Model creature crematory burning rate from 20-400kgs per hour. Heavy duty combustion room and match for large animal cremation.  Residency time 2.0 sec. In post combustion chamber. Practically smoke and odor free. 

Smoke Filter Chamber with filter brick, Virtually smoke and odor free after burning. 

Italy original gas or oil burner, quality dependable. It suit for petrol oil, natural gas, LPG gas. 

User guider, full setup and operation record for customer.

Items/Model A360 A600 A900 A1200
Burning Rate *animal 20 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 60 kgs/Hr.
Feed Capacity *animal 30 kgs 50 kgs 80 kgs 100 kgs
Equipment Weight 2300 kgs 3000 kgs 4000 kgs 4300 kgs
Primary Chamber (Liters) 360 600 900 1200
Secondary Chamber (Liters) 200 200 300 500
External Dimensions (cm) 145x90x175 175 x 100 x 180 200x160x230 220x180x360
Internal Dimensions (cm) 100x60x60 130 x 70 x 65 120x90x85 130x100x90
Oil Tank(Liters) 200 200 300 300
Door Opening (cm) 48 x 60 50 x 60 62 x 80 55 x 80
Chimney (M) 5 5 5 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Light Weight Small-Scale Medical, Mobile Optional Kind


Light Weight Small-Scale Medical, Mobile Optional Type


Model YD-30 
Picture

 
Burning Rate  average 30 kgs/hour
Feed Capacity average 40 kgs
Paimary Combustion Chamber 200 Liters
Secondary Combustion Chamber 100 Liters
Mix Combustion Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.59Kw
Fuel Type Diesel Oil
Burner Italy Original
Oil Consumption (Diesel Oil) average 13.3 kg/hour
Gas Consumption (Natural Gas) ***
Internal Dimensions 80 x 50 x 50cm (primary chamber)
External Dimensions 125 x 90 x 180cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 60 Liters
Door Opening 40 x 40cm
Chimney Length 1.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 1500 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800–1000
Secondary Chamber Temperature 1000-1200
Residency Time 2.0 Sec.
Burning Efficiency 98%
Waste Lower Calorific Power 3000Kcal
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 


hospital incinerator distributor



CSH Wellness Facility, (Calabar, Nigeria)

Mmedical waste burner qualified of obtaining rid of roughly 0.5 cubic meter of pathological or contagious waste.

Burner to have twin burning chamber as well as control amount of dioxin as well as various other gasses discharged without being damaging.

Approximated measurements, to distributors common, nevertheless to be portable as practical.
Established to shed disposables that can along with need to be destroyed on-site. Theses wastes include additionally polluted as well as transmittable “red bag.” Surgical dressings, plastic evaluation devices as well as additionally other wastes.
Quick, complete, trustworthy waste disposal.
Dual chamber burning, Chambers shielded in addition to lined with heat refractory. Programmable electronic temperature level controls, temperature level indicators as well as likewise charge recorder. Regulating control for gas and also air lowers gas consumption.
Minimum installation along with launch time.
Aluminized steel layer lined with refractory as well as likewise firebrick. Displays recorders in addition to various other accessory devices should certainly be provided.
Billing system:.
– – Upright cost door on key chamber.
– – Pneumatically-driven or hydraulic ram payment system.
– – Car closed down of the door after charging.
– – Primary as well as second chamber temperature provided as well as likewise taped (optional).
Billing cost:.
– – About 100kgs per human resources of waste or red bag waste ranked at 2200 BTU’s per kg.
Gas:- Gas.
Capacity (Cubic Mtr): 1.65 M3 or perhaps more.
Ave Capacity: 100kg per hour.
Extra Chamber Ability (CubicMtr):3.88 and even much more.
Size (mm): 1880 or better.
Size (mm): 1280 or far better.
Height Incl. Flue (mm): 7700 or far better.
Ash Door Opening (mm): 475 × 900 or much better.
Min. Running temperature: 90 level centigrade.
Max, Operating Temperature: 1350 level centigrade.
Residency time in Second Chamber: 2 sec.
Temperature level Tracking: Both for essential as well as also additional chambers.
Packing SystemManual/semi-automatic.
Waste damages efficiency: > > 90% by weight.
Filter: Numerous or ceramic various other equivalent filters in order to lower the induction of hazardous air impurities, particulates, carbon monoxide, dioxin/furane right into the ambience.
De ashing system: Manual/semi-automatic.
– Civil functions. – Waste collection Trolleys

Total/ Paint:-.
Premium top quality warm immune, 2 layers modern epoxy Paint layer.
Set Up Power (Electric Voltage): 440V/ 50 Hz.
Waste Monitoring Equipment should have;.
Mobile packaging cart: 06 No’s– – For transportation of health center waste from wards to heater site/ location, Opening up from the top.
WASTE BINS MOBILE: 06 No’s- Created from Plastic, in blue color with a cover flap.
Plastic Bags: 2000 no’s each in Red as well as likewise Yellow shade.
Sturdy Hand Protection Pairs: For Waste handling staff-06 Pairs.
Lengthy Shoes Pairs: For waste handling– – 06 Pairs.

CSH Health And Wellness Facility, (Calabar, Nigeria)

Mmedical waste heater capable of obtaining rid of roughly 0.5 cubic meter of pathological or transmittable waste.



Medical Waste Incinerator


Basic Info.

Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

Key Attributes:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according to sequence * High temperature, long lifetime of incinerator.  * Free or minimal installation on site.  * High speed, from 10kgs to 500kgs per hour, up to 6ton daily.  * PLC Control Plane. *according to order  * New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and parts in stock.  We provide technology service, installation support and client made.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Farm Incinerator


Basic Info.

Model NO.:farm animal equipment cremation creamatotium incin
Export Markets:Global

Product Description

Key Attributes:  * All models with Dual combustion room.  * Stainless Steel chimney/stack, long life. *according to order  * High temperature, long life of incinerator.  * Free or minimal installation onsite.  * High speed, from 10kgs to 500kgs per hour, up to 6ton daily.  *according to order  New Design for pet animal cremation business.  * One year warranty on incinerator and components in stock. 

Program Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation 

Incinerator is a incineration equipment, direct flame thermal oxidiser china, thermal oxidizer china, thermal oxidizer, poisonous gas waste disposal incinerator, poisonous wast provider in china, trailer mounted animal carcass incinerator, waste by gas fuel or oi gas. As distinct circumscription, incinerator could be named many words as under: 

Treatment capacity: Small scale incinerator, big scale incinerator and incineration pant. 

Waste substance: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators 

Incinerator gas: Gas incinerator, oil incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. 

Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 

Burning Speed: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Device Measurement : Burning Rate : 60-80 kg/hr Pyrolytic Double Chamber Burner



Items/Model

TS100( PLC)

Image

Concept

Waste Incineration Treatment

Shed Rate

60-80 kg/hour

Control Setting

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

1200L

Inside Measurements

120x100x100cm

Second Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Establishing

Manual

Voltage

220V

Oil Usage (kg/hour)

Common 20.4

Gas Consumption (m3/hour)

***

Temperature Level Monitor

Digital Existing

Temperature Level Degree Defense

Yes

Oil Container

1100L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless Steel

1st. Chamber Temperature

800 ℃– – -1000 ℃

second. Chamber Temperature Level Degree

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

Outside Measurements

260x150x180cm


The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using diesel 
fuel as a supplemental fuel oil.
It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.
The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapid 
deployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are several 
variations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 years 
if the specified maintenance schedule is followed.
The incinerators should be supplied assembled, whenever possible, and all parts and components should be 
packaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130) 
and via sea in a 20’ ISO sea shipping containers.

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21



tiny range burner



It must have the capacity to run not less than 10 hours/day

This burner must be able to wreck all flammable wastes produced by medical centers, personal facilities, study laboratories, institutes, and also so on. 400 and its elevation: 8 m

The Quantity of the burning chamber a minimum of: 1.200 L

The Measurement of the door for filling up in centimeters a minimum of: 70 × 70.: diesel

Manufacturer to provide essential information for the extremely best of the installment

The control board will have all appropriate audible and visual alarm systems to make sure safe operation.
A burning chamber of waste: oPerfectly limited door for the hands-on loading of waste. The loading should be Guidebook, Establish Lots oA heater of lights which the usage is limited to the ignition of waste. oFrontage of packing with door seals increased on joints, wheel of screw plug, flexible joint, as well as packing safeguarding out of refractory. oThe insulation of the burning chamber require to be composed of refractory blocks, having a high internet content of aluminium in addition to insulates bricks in order to ensure a minimum temperature outside sheet metal. o Framework of the refractory;

? Refractory concrete:. Density: ≥ 100 mm. Nature: 42 %of Al203? Shield in fibrous panels: Thickness: ≥ 75 mm Nature: Calcium silicate.? Burner of illumination of waste, with gas, traditional mono-bloc dispersing routing plunging fire, lighting and likewise safety as well as security of electronic ignition, irreversible ventilation,
electromagnetic sluice gateway of guideline and also isolating valve.
Plate of burning in Carborundum, protecting against the repairing of glass along with slags

A chamber of article burning of gases oA heating system of burning of gases, oA gizmo of injection of air permitting a complete recombustion of gases, oA tool of air inlet of a/c of waste gases, oA sheath of discharge of the gases charred. oCarcass in solid
Refractory concrete:? Nature: 65% of Al203? Nature: Calcium oBurner with gas, mono-bloc spreading guiding kind with straight fire, illumination as well as safety and safety of digital ignition, lasting ventilation, electro-magnetic sluice entry of guideline and additionally dividing shutoff.
oA 2nd shot of air to ensure superb oxygen material.

A control box ensuring the total cycle of burning.

Fan: oElectro-ventilator dispersing the 2nd air, the guideline of the air blood circulation being executed by shutoffs as well as additionally adhering to the control of the automatic cycle. Controls and also guidelines: Control box watertight to dust, containing:

A button circuit breaker for every engine (ventilators along with heaters). A timer with flexible temporization for the standard of each burner. A regulatory authority with look for the temperature degree of burning. A regulatory authority with watch for the temperature of message burning. Electric box

The additional
shedding chamber must damage the pollutant item and should resist to high temperature( 1100 ° C)

Refine Filtering system: Scruber to be mentionned as optional

It ought to have the capacity to run not much less than 10 hours/day

This incinerator should be able to destroy all combustible wastes created by medical facilities, personal centers, research study labs, institutes, and so on.

Design Spec: Kinds A, B, C, D, and also E of scientific waste

“PYROLYTIC” burning, by regulating the gasification of waste. 400 and also its elevation: 8 m

The Quantity of the combustion chamber a minimum of: 1.200 L

The Measurement of the door for filling up in centimeters a minimum of: 70 × 70.: diesel

Supplier to provide essential details for the extremely ideal of the installation

The control board shall have all ideal distinct as well as aesthetic alarm systems to make certain secure procedure.

This burner with” PYROLYTIC “shedding requirement to have: 1.

Burner procedure ought to be Automatic On/Off Fuel?: diesel

Manufacturer to give necessary details for the very best of the installment

The control board shall have all suitable audible and aesthetic alarms to make sure safe operation.

This burner with” PYROLYTIC “burning need to have: 1.
A burning chamber of waste: oPerfectly tight door for the hands-on loading of waste. The loading should be Manual, Set Load oA heater of lighting which the use is restricted to the ignition of waste. oFrontage of loading with door seals increased on joints, wheel of screw plug, flexible joint, as well as stuffing protecting out of refractory. oThe insulation of the burning chamber need to be composed of refractory bricks, having a high web content of aluminium as well as insulates bricks in order to ensure a minimum temperature outside sheet metal. o Structure of the refractory;

? Refractory concrete:. Density: ≥ 100 mm. Nature: 42 %of Al203? Insulate in fibrous panels: Thickness: ≥ 75 mm Nature: Calcium silicate.? Burner of illumination of waste, with fuel, conventional mono-bloc spreading directing plunging fire, illumination and also safety and security of digital ignition, irreversible ventilation,
electromagnetic sluice gate of regulation and isolating valve.
Plate of combustion in Carborundum, preventing the fixing of glass as well as slags

A chamber of post burning of gases oA heater of burning of gases, oA gadget of injection of air allowing a complete recombustion of gases, oA tool of air inlet of air conditioning of waste gases, oA sheath of discharge of the gases charred. oCarcass in solid
sheet steel with assistance of connection. oComposition of the refractory;? Refractory concrete:? Thickness: ≥ 150 mm? Nature: 65% of Al203? Insulate in fibrous panel:? Density: ≥ 85 mm? Nature: Calcium oBurner with gas, mono-bloc spreading directing kind with straight flame, illumination as well as safety and security of digital ignition, long-term ventilation, electromagnetic sluice entrance of regulation and also separating shutoff.
oA second shot of air to guarantee excellent oxygen material.

A control box guaranteeing the complete cycle of combustion.

Follower: oElectro-ventilator dispersing the second air, the regulation of the air circulation being carried out by valves and also adhering to the control of the automated cycle. Controls and also guidelines: Control box watertight to dust, consisting of:

A button circuit breaker for every engine (ventilators as well as burners). A timer with flexible temporization for the guideline of each burner. A regulator with watch for the temperature level of burning. A regulatory authority with digital watching for the temperature of message burning. Electric box

The secondary
burning chamber should damage the pollutant item and must resist to high temperature( 1100 ° C)

Refine Filtering system: Scruber to be mentionned as optional