Incinerators


Basic Info.

Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

Nanjing Clover Medical Technology Co., Ltd..

Key Features:  * All model with Dual combustion room (AB chamber).  * High fever, long life of incinerator.  * Free or minimal installation onsite.  * High burn speed of up to 500kg each hour.  * Layout to health care waste and animal cremation.  * One year warranty on incinerator.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Cremation Equipment


Product Description

Incinerator is a incineration gear, direct fire squander by gas fuel or oi fuel. As distinct circumscription, incinerator can be termed many words as under: 

Treatment capacity: Small scale incinerator, big scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators  Incinerator fuel: Gas incinerator, petroleum incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer.  Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)  Burning Speed: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

Pyrolytic incineration technical is conventional waste treatment solution for several years. All around the planet, in most countries, people anti incinerator since the incinerator will create a large Dioxin from the smoke. Dioxins break down very slowly and past releases of dioxins from the natural and man-made resources still exist in the surroundings. Anyhow, we have to remind that, this is big scale incineration pant, normally greater than 30 ton per day. This is a societal problem, to examine and suggest ways in various angles in the general public, government, economic growth, environmental protection, technology development, etc. 

So, why we use incinerator?  First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management.  Secondly, for individual body, pet creature, in most countries and areas, we desire to cremation them. This is the service in the procedure for society growth, and ceremonies to commemorate the disappearance of existence. 

As previously two rationale although not only above, we still use incinerators. 

the way you are able to discover reasonable incinerator for your regional site?  Incinerator isn’t a inexpensive equipment, normally the small scale version 's cost around $5, 000USD per unit and big scale version 's cost more than $50, 000USD each unit. Thus, before buy one unit incinerator, you have to make clear following things: A, burn what? Incinerator is a incineration gear, function is fire waste. So what sort of waste you want to cure?  B, small or big? This based on the waste output daily or the waste quantity per feed period, like creature size.  C, fuel? Incinerator use gas or oil , normally, gas fuel is less expensive than oil and also the smoke cleaner than petroleum fuel model. But some neighborhood site don't have gas distribution system. Incinerator, dual chamber medical waste incinerator specifications, dual chamber waste incinerator manufacturers, economic incinerator,  And other technology items, like power(220V, 380V), waste feed doorway kind, incinerator structure, etc..

After you clarify them, you can go to locate a local or global manufacturers, asking prices, technical specifications and finally buying the correct products.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

small incinarator


heavy Duty Steel casing

 

High Quality refectory lining & insulation

 

1 x Diesel fired ignition burners operated on / off

 

Front Loading Door (safety catch

 

Separate Ash removal Door

 

 

2.7  CONTROL UNIT

 

  1. The entire processing cycle and the combined effect of the individual components of the incinerator shall be

achieved by a central control unit.

 

  1. The control panel shall consist of a standardized sprayed sheet steel shell with doors and the necessary

mounting supports and contains all the devices such as relays, time switch, safety device, contactors, regulator,

display devices, recorder, selection, on, off and main switches, and indicator lamps required for the control,

regulating and registration.


Incinerator Combustion


Product Description

Keyword:  Small incinerators  Medical waste incinerator  Pet animal cremation incinerator  Incinerator manufacturers 

Incinerator is a incineration equipment, direct fire squander by gas fuel or oi gas. As distinct circumscription, incinerator could be termed many words as below: 

Therapy capacity: Small scale incinerator, large scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators  Incinerator gas: Gas incinerator, oil incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer.  All around the planet, in most nations, people anti incinerator because the incinerator will produce a sizable Dioxin in the smoke. Dioxins could be released into the environment through forest fires, backyard burning of trash, specific industrial activities, 100kg capacity incinerator manufacturer in China, 10kg capacity incinerator, 10kgs per hour incinerator, 15 mph incinerator price, 150 kg puppy, 150kg. Net, and residue from previous business burning of waste. Dioxins break down very slowly and previous releases of dioxins from both man-made and natural resources still exist in the surroundings. Anyhow, we have to remind that, this is large scale incineration pant, normally more than 30 ton daily. This is a social problem, to examine and indicate ways in various angles in the general public, government, economic growth, environmental protection, technology development, etc. 

So, why we use incinerator?  To begin with, for your medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can ruin the virus, pollution management.  Secondly, for human body, pet creature, in most nations and regions, we want to cremation them. This is the ceremony in the procedure for society growth, and ceremonies to commemorate the disappearance of existence. 

As above two reason but not just above, we still use incinerators. 

How you can discover reasonable incinerator for your regional site?  Incinerator is not a cheap equipment, normally the little scale version 's price approximately $5, 000USD per unit and large scale version 's price more than $50, 000USD per unit. So, before buy one unit incinerator, you need to make clear after things: A, burn what? Incinerator is a incineration equipment, function is flame squander. So what kind of waste you want to cure?  B, little or large? This based on the waste output daily or the waste quantity per feed period, like creature dimensions.  C, fuel? Incinerator use oil or gas , normally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some neighborhood site don't have gas supply system.  And other technology items, like electricity (220V, 380V), waste feed door kind, incinerator construction, etc. 

After you describe these, it is possible to go to discover a local or global manufacturers, requesting prices, technical specifications and finally purchasing the right products. 

Wrote by Nicky

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Incinerators differ from the simpler methods of burning


Incinerators differ from the simpler methods of open burning since the owner has a greater level of control over the burning process. The resulting higher temperatures, more holding times and greater turbulence lead to more complete combustion of the waste. Although a larger variety of wastes could be destroyed using high temperature single or dual-chambered incinerators, determined attempts should nevertheless be taken to decrease the quantity and type of waste generated and to implement other modifications which would result in reductions in air emissions. Refer to section 3 for additional information appropriate waste management practices and a list of what waste can and cannot be incinerated.

The incinerator manufacturer’s operating instructions should be followed in any way times to guarantee designed temperature, holding time and turbulence requirements are attained and to avoid harm to the facility. When operating during winter months, additional care must be taken because chilly air introduced into the primary and secondary chambers can make it hard for ordinary operating temperatures to be attained. Operators must be properly trained and qualified to operate the equipment under both normal and emergency conditions. Owners are strongly encouraged to consult with manufacturers or other qualified persons with expertise before buying an incinerator. Additional advice on the selection of incinerator technology and their operational requirements can be obtained by referring to Environment Canada’s Technical Document for Batch Waste Incineration.

The setup and operation of monitoring and control systems is essential for the proper and safe operation of any incinerator.  The design, installation, certification and operation of continuous emissions monitoring systems (CEMS) must comply with the principles explained in Environment Canada’s Protocols and Performance Specifications for Continuous Monitoring of Gaseous Emissions  from Thermal Power Generation. For incinerators operating in Nunavut, crucial operational parameters have to be monitored in any way times using on-line tools capable of measuring the combustion process and stack emissions caliber. These tools should be outfitted with visible and audible alarms and be on-line whenever the incinerator is in operation, including’startup’ and’cool down’ phases. Table 3 lists the tracking and control system requirements.


Waste Incinerator


Basic Info.

Model NO.:waste incineration furnace
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Medical Incinerator Main Combustion Price


Product Description

Incinerator is a incineration gear, direct fire waste by gasoline fuel or oi fuel. As distinct circumscription, incinerator could be named many words as under: 

Therapy ability: Small scale incinerator, large scale incinerator and incineration pant.  All around the planet, in many countries, people anti incinerator because the incinerator will create a large Dioxin from the smoke. Dioxins break down very slowly and previous releases of dioxins from the man-made and natural resources still exist from the environment. Anyhow, we have to remind that, this is large scale incineration pant, normally more than 30 ton per day. This is a societal problem, to examine and suggest ways in various angles from the general public, government, economic development, environmental protection, technology advancement, etc. 

So, why we use incinerator?  To begin with, for your medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management.  Second, for individual body, pet animal, in many countries and areas, we want to cremation them. This is the service in the process of society development, and ceremonies to commemorate the disappearance of existence. 

As above two rationale although not only above, we nevertheless utilize incinerators. 

How you are able to find reasonable incinerator for your neighborhood website?  Incinerator is not a cheap equipment, normally the small scale model's cost around $5, 000USD per unit and large scale model's cost more than $50, 000USD per unit. So, before buy one unit incinerator, you need to make clear following things: A, burn out what? Incinerator is a incineration gear, function is fire waste. So what kind of waste you would like to cure?  B, small or large? This based on the waste output daily or the waste quantity per feed time, like animal dimensions.  C, fuel? Incinerator use gas or oil fuel, normally, gas fuel is cheaper than oil and the smoke cleaner than petroleum fuel model. But some neighborhood website don't have gasoline distribution system.  Along with other tech products, such as electricity (220V, 380V), waste feed doorway type, incinerator construction, etc. 

Once you describe these, it is possible to go to find a local or international producers, asking prices, technical specifications and ultimately buying the ideal products.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

animal incinerator


Logic Programmed Control of 2 Burners

Range Of Pre-Set Burn Times

Fuel Saving Burner Efficiency Control Program with Constantly Running Fans

Temperature Monitoring With Separate Displays for Primary/ Secondary Chambers

Auto Control

Manual Control

Timer Control 0-24 Hours

Integral Fun Timer Control

 

 

Operating Features

 

Time to Temperature: 35 Minutes

Fuel Consumption: Gas or 8 Liters per Hour (Diesel) Or Less

Burning Capacity about 30-40Kg/Hr

Weatherproof (Ip65) Control Panel with PLC Showing Operation & Temperatures

Recommended Loading Being By Regular ‘Top Ups’ For Efficient Combustion

Primary Chamber Burners Automatically Switched Off At 900C for Fuel Efficiency

Dry Ash Waste Can Be Removed By Vacuum Unit Is Required

Electricity Supply: 230V, 50H, 10amp, Single Phase

Machine Shipped In Two Section

Chimney Mounted On Fabricated Flanges