Product Description
Technology Respond(FAQ)
Q: What’s kind of waste may utilize within this gear? A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation substance, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Remedy capacity A: Typical Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour)doesn’t indicate any waste material. The animal/pet combustion speed around 2/3 of average power.
Clover incinerator utilize time daily to 24 hours. Between each feed/combustion time, there are approximately 0.5-1 hours cooling time and time for feeding squander. Actual combustion time daily is around 16 hours. The life of incinerator involving 5-10 year according to utilize.
Ordinarily, we proposal small lab, small clinic use capability under 20 kgs per hour. When incinerator use in hospital, then please compute the waste output around 2kgs per people per day. If there are 200 sickbed at the clinic, that's mean you need one incinerator capability around 400kgs per day, switch to power per hour is approximately 30-40 kgs per hour. 300 kg incinerator, animal cremation burners, animal incinerators china, china medical waste incinerator, china+incinerator, hospital incinerator manufacturer, According the performance time per day, waste material, budget, growth, etc, you may use ability from 30-50 kgs per hour incinerator. *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Assembly and Testing A: We supply all documents and incinerators easy to installation and functionality. Client can send people come to our factory to learn operation and installation. Generally, We do not send engineer to neighborhood website or even ask. The dispatch cost is extra according to order.
Q: Combustion Temperature A: The very first combustion chamber: 800-1000 centi degree. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control manner is common control case. PLC mode according to order and model.
Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD annually maintenance according model, use scenario.
One individual can service 02 unit incinerators. The staff should have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and know threat of medical waste to protect worker self with essential security element.
Items/Model |
TS10(PLC) |
TS20(PLC) |
TS30(PLC) |
TS50(PLC) |
TS100(PLC) |
Burn Rate |
10 kg/hour |
20 kg/hour |
30 kg/hour |
50 kg/hour |
100 kg/hour |
Feed Capacity |
20kg |
40kg |
60kg |
100kg |
200 kg |
Control Mode |
PLC |
PLC |
PLC |
PLC |
PLC |
Combustion Chamber |
100L |
210L |
330L |
560L |
1200L |
Internal Dimensions |
50x50x40cm |
65x65x50cm |
75x75x60cm |
100x80x70cm |
120x100x100cm |
Secondary Chamber |
50L |
110L |
180L |
280L |
600L |
Smoke Filter Chamber |
Yes |
Yes |
Yes |
Yes |
Yes |
Feed Mode |
Manual |
Manual |
Manual |
Manual |
Manual |
Voltage |
220V |
220V |
220V |
220V |
220V |
Power |
0.5Kw |
0.5Kw |
0.5Kw |
0.7Kw |
0.7Kw |
Oil Consumption (kg/hour) |
5.4–12.6 |
7.8–16.3 |
10.2–20 |
12.1–24 |
14–28 |
Gas Consumption (m3/hour) |
6.2–11.4 |
8–15.7 |
9.8–20 |
9.9–26.1 |
10–32.2 |
Temperature Monitor |
Yes |
Yes |
Yes |
Yes |
Yes |
Temperature Protection |
Yes |
Yes |
Yes |
Yes |
Yes |
Oil Tank |
100L |
100L |
100L |
100L |
200L |
Feed Door |
30x30cm |
45x40cm |
55x50cm |
70x55cm |
80x60cm |
Chimney |
3Meter |
3Meter |
5Meter |
5Meter |
10Meter |
Chimney Type |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Residency Time |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
Gross Weight |
1500kg |
2200kg |
3000kg |
4500kg |
6000kg |
External Dimensions |
140x90x120cm |
160x110x130cm |
175x120x140cm |
230x130x155cm |
260x150x180cm |