Waste Incinerator Yd-100


Product Description

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chmaber Temperature 1000degree-1200degree 1000degree-1200degree 1000degree-1200degree 1000degree-1200degree

Nanjing Clover Medical Technology Co., Ltd..

maker of ha zardous waste heater in china



Burning Capability: 125 kg minimum/time (3-6times/ day), twin chamber, double burning system
Assigning door Mouth Size (mm): 760 * 760 (approx.).
Smokeshaft External Size (mm): 300 ± 10.
Combustion Improver Tool: 0.11 kw, Fuel intake: 7kg/ hr (max).
Re-Burning Tool: Oil intake: 5kg/h, 0.37 kw, Oil usage: 10-20kg/ h.
Voltage: 380v/220v Air Conditioning System, Service Guarantee: 1 Year, 50 Hz

Per your promotion for 300 kg.hr. Version– – We require to know the rate with return.

The amount of Kg. of Gas would be needed for running this Style 10 hrs. everyday.

We have our own Products Forwarding Agent.

We had an Agreement for Waste Keeping an eye on before their Civil Fight for 120 Tons/Day for one Town in North Africa.
Medical Waste Heater

Double Chamber (Key & & & & Secondary) with insulation pieces (totally insulated internal refractory lining) in addition to

managed air blower for each chamber

Insulation/ Refractory Density: ≥ 100mm

Chamber plate thickness: ≥ 6mm

Fuel Kind: Gas based upon losing gas in combustion chambers

Waste Capacity: ≈ 150 Kg/Day

Incineration capability: ≈ 25 Kg/Day (Various waste invoicing in addition to waste elimination doors)

Heaters: At the very least with (02) heaters of automated start as well as give up functions

Combustion performance: > > 97%

Temperature level: programmable temperature level with temp monitoring system

Home time: 2 second in secondary chamber

Home heating value: 4000 Kcal

Temperature Level Selection: ≈ minutes 800ºC to max 1200ºC

Electrical supply: 220V with solitary phase

Smokeshaft Plate Density: ≥ 5mm

Water scrubber: Rubbing making use of reagent like lime & & & & must constructed from SS 10 scale of non-corrosion residential properties as well as painted

exteriorly by devices quality heat repellent enamel

Chimney Elevation: in between 15-25 feet



Little Incinerator Primary Chamber Secondary


Basic Info.

Model NO.:small incinerator medical waste manufacturer
Export Markets:Global

Product Description

Incinerator is a incineration gear, direct fire squander by gasoline fuel or oi fuel. As distinct circumscription, incinerator could be termed many words as below: 

Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant.  All around the world, in many nations, people anti incinerator because dead animal incinerator manufacturers, dead pet cremation equipment, diesel pet incinerator, nationally incinerator china, double chambered incineration, double room medical the incinerator will create a large Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological features. Dioxins could be released into the environment through woods fires, backyard burning of garbage, certain industrial activities, and residue from previous business burning of waste. Dioxins break down very slowly and previous releases of dioxins from both man-made and natural resources still exist in the surroundings. Anyhow, we have to remind this, that is large scale incineration pant, generally greater than 30 ton every day. This is a social issue, to examine and suggest ways in various angles in the public, government, economic growth, environmental protection, technology advancement, etc. 

So, why we use incinerator?  To begin with, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can ruin the virus, pollution control.  Second, for human body, pet creature, in most nations and regions, we want to cremation them. This is the service in the process of society growth, and ceremonies to commemorate the disappearance of existence. 

As preceding two motive but not just above, we nevertheless use incinerators. 

How you are able to find reasonable incinerator to your regional website?  Incinerator isn’t a cheap equipment, generally the little scale model's cost around $5, 000USD per unit and large scale model's cost more than $50, 000USD per unit. So, before buy one unit incinerator, you need to make clear following items: A, burn what? Incinerator is a incineration gear, function is flame squander. So what kind of waste you want to cure?  B, little or large? This based on the waste output every day or the waste volume per feed time, like creature dimensions.  Incinerator use gas or oil fuel, generally, gas fuel is less expensive than oil and also the smoke cleaner than oil gas version. However, some local website don't have gasoline supply system.  And other technology items, like electricity (220V, 380V), waste feed doorway type, incinerator structure, etc. 

Once you explain these, it is possible to go to find a local or global manufacturers, asking prices, technical specifications and finally buying the right products.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Biomedical Waste Heater, 10-15 KG.


The machine provided will be made to store and to function normally under the requirements of
Chimney of 30 meters Height:
System Configuration
Maintenance Service during Warranty Period
Epoxy powder coated washable paint finish.
Average fuel consumption: ~29 kg per hour ( Or diminished )
Material: Insulation bricks confirming to international standard.
The bidder must submit diesel consumption for a daily operation of 6 hours.
The bidder must arrange for the equipment to be installed and commissioned by certified or
User (Operating) manual in English.
Power supply: 220-240 VAC, 50Hz single phase/400 — 420 VAC, 50Hz three phase as
above).
Type / Model:

Material: Refractory bricks confirming to international standard.
Modulation: Manual damper control
Type: Centrifugal
Material of Construction: Light steel.
Percent CO2 + percent CO
Temperature: Main Chamber 800 ± 50 oC, Secondary Chamber 1050 ± 50 oC.
Main Chamber:
Type: Centrifugal
It will have 3mm thick rubber lining from inside for security.
It will come with aviation , lightening arrestor, pile, drain, review platform, sampling
I.D. Fan:
Turnkey:
Installation and Commissioning
All compulsory approvals required for the installation and operation of incinerator will be performed
Insulation thickness: approx.115mm thick
Material of Construction: CRCA sheet
It will have acceptance of”Pollution Control Board” of buyer’s state.
Type: Cyclonic
Drive: Bel
Material of Construction: Stainless Steel 304, impeller and mild steel rubber lined casting
Documentation
Type: Static Solid Hearth
Parameters                   Concentration in mg/Nm3 (12% CO2 correction
It will have burning capability 10-15 kg/hr.
Second is a 500kg per/hr incinerator for a company planning to start a
Shall supply pump motor of suitable capacity.
Fuel Oil Storage Tank:
Destruction Efficiency: 99%.
Piping : PPR
Warranty
Fuel: Diesel
Bidder will submit detail drawings, design, and design plan of civil functions.
List of important spare Components and accessories with their part number and costing.
Scrubbing Media: Water with 5% caustic
Switches necessary for installation & commissioning of the equipment.
It will be self-supporting kind.
Burner: Monoblock fully automatic leftovers.


health care facility for melting contaminated materials along with chimicals



use in the health center for melting contaminated materials as well as chimicals, marginal Capacity 300 per hr. I will be marketing to my client?. Below is the information I was provided as well as definitely nothing else. The healthcare facility burner for usage in the professional waste as required by worldwide ecological administration. Minimum 300 Kg capacity/hr, Gas released, refractory lined, smokeshaft along with tasting prot. Minimum temperature level of 1100 level Celsiu.the incinerator tool for shed 500kg per hr. work concerning shed clinical waste of the hospitals.Just want to price of you different kinds of Medical Trash Incinerators.need all info on 300 kg per hr system. availability. practical expenses making use of diesel (numerous other). the waste is Human Cells. And also we have 10 kg each day; we require burner for scientific waste.Burn Capacity: 50kgs per hr (Ordinary capacity according to Medical Waste). please forward information regarding prices on each of you pet crematory models.Regarding Gas Incinerator, Please note that Fuel for the Incinerator
will be Gas. As gas is contribute our country.



Large General waste incinerator Burn Price as much as 250kg per hr



Items/Model

TS300( PLC)

Concept

Waste Incineration Therapy

Burn Price

Average 250 kg/hour

Control Setting

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

2000L

Interior Dimensions

170x120x100cm

Secondary Chamber

1000L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

2.5 Kw

Oil Intake (kg/hour)

Average 28( DO)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Present

Temperature Defense

Yes

Oil Tank

1000L

Feed Door

80x60cm

Chimney

10Meter

Smokeshaft Type

Stainless Steel

1st.

Gross Weight

11000kg

External Dimensions

400x210x300cm( without chimney)

2020-03-22

400x210x300cm(without chimney)

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-22



Waste Incinerators From Chinawaste, Incinerators


Product Description

Incinerator is a incineration equipment, direct fire squander by gasoline fuel or oi fuel. As distinct circumscription, incinerator could be termed many words as below: 

Therapy capacity: Small scale incinerator, big scale incinerator and incineration pant.  All over the world, in most nations, individuals anti incinerator because the incinerator will produce a large Dioxin from the smoke. “Dioxins” refers to a group of poisonous chemical compounds that share certain chemical structures and biological characteristics. China ecological incinerator manufacturers, China horse cremation incinerators, China incenarators for sale, China incinerators company, China incinertor inkjet version yd 500, Dioxins can be released into the environment through woods fires, backyard burning of trash, certain industrial activities, and residue from beyond business burning of waste. Dioxins break down very slowly and previous releases of dioxins from the man-made and natural sources still exist from the surroundings. Anyhow, we have to remind that, this is big scale incineration pant, generally greater than 30 ton every day. This is a societal problem, to examine and indicate ways in various angles from the public, government, economic development, environmental protection, technology advancement, etc. 

So, why we use incinerator?  To begin with, for your medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management.  Second, for human body, pet creature, in most nations and areas, we desire to cremation them.

As previously two rationale but not just above, we nevertheless utilize incinerators. 

the way you can find reasonable incinerator for your local site?  Incinerator isn’t a cheap equipment, generally the small scale version 's price around $5, 000USD per unit and big scale version 's price more than $50, 000USD per unit. So, before purchase one unit incinerator, you need to make clear following items: A, burn what? Incinerator is a incineration equipment, function is fire squander. So what sort of waste that you want to cure?  B, small or big? This based on the waste output daily or the waste volume per feed period, like creature size.  C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil gas version. However, some neighborhood site don't have gasoline supply system.  And other technology products, like power(220V, 380V), waste feed door type, incinerator construction, etc. 

Once you describe these, you can go to find a local or international manufacturers, asking prices, technical specifications and finally purchasing the ideal products.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm