waste incinerator manufacturers china


Capacity    Not less than 500Kg/hr.
Operation    24hr-7days/week continuous operation.
Combustion chamber    2 combustion chamber.
Temp.    First combustion chamber 800-1000 C.
Secandry combustion chamber 1000-1200 C, with the possibility to be upgraded to 1400 C.
Combustion Efficiency    99.99%
Retention time    Of the flow gases not less than 2 Sec in the hot portion.
Excess Oxygen concentration    Of primary combustion chamber 3-6% max.
Refractory    The chambers should be lined with high thermal insulating refractory bricks with suitable thickness and with highly temp. resistance. Not less than 1400 C for the first combustion chamber, and not less than 1600 C for the secandry combustion chamber, and at the same time prevent the Temp. of the outside body of the chamber not higher than 70 C.
Doors    Should be lined with the same bricks, and the edges lined with special suitable insulating material to prevent any gas escaping, and the doors should be kept under negative pressure during the operation.
Air Emission Control System    With high destruction and removal efficiency (DRE). Not less than 99.9999 as per KEPA.
Wet System    If the system equiped with a CEMS washing the flow gas with water, then it should be manufactured from suitable anti corrossion materials, and equiped with pH meter to measure and neutralize the water. It should be able to use the water in closed recycled circuit many times before treating/ discharging into the sewage system in compliance with KEPARS.
Chemical dosing    It should be equiped with suitable autochemical dosing system to control the pH for the water of the wet scrubber system including sensors.
Chimney    It should be suitable with the capacity and the technical specifications, with height not less than 12m from ground level. With easy opennable sampling point equal about 3 inch, and the optimum sampling locations is at least 8D downstream direction and 2D upstream from any flow disturbancies.
Sampling point    Should be equiped with a platform located down the sampling point by a distance not less than 1 m, and equiped with suitable stairs from ground to the port with comfortable slope.
Ash Removal    It should be auto ash removal system.
Fuel    It should be dual system, such as diesel and natural gas.
Feeding System    Should be auto feeding system into primary chamber.
Control Room    Should be equiped with a control panel shows Temp. of the combustion burners, gas monitoring, digital Temp. indecation for the primary/secondary chambers, digital Temp. indication for the gases…etc. it should be also Auto operation, burnures on/off auto lamps switch, auto start/stop for air emission control system, auto gas continuous monitoring system reading and print out of gas emission parameters…etc.
Cooling System    The primary chamber should be provided with auto cooling systemthrough nozzles to permit direct cooling if the Temp. will be heigher than 1100 C.
Inter-lock system    The incinerator should be equiped with inter-lock system to prevent feeding the waste to the primary chamber if the combustion Temp. less than 500 C.
Flue treatment and cleaning    To consist a combined system (wet/dry), using water, lime, active carbon and ceramic filters.
Quenching system/Heat exchanger    Should be made and manufactured from anti corrosion and acid attack materials such as stainless steel 316 or equivalent.
Noise Level    Not more than 85 dBA during normal operation.
Inaddition    The desigh should insure that responsive fail-safe control systems are used.
The incinerator should be installed inside closed suitable building with good aeration and ventilation system. The building has facilities for off-loading of wastes from transport vehicles. Auto cleaning system for trucks and waste containers, and cool storage area…etc.
The quotation should included list of original spare parts for 7 years.
The quotation should include supervising, starting up and training of the operators and ministry of health engineers inside/outside Kuwait.
Detailed drawings, catalogs should be included.


Waste Incinerator


Product Description

Waste Incinerator International Market Analytics  Date.

Key Word:  Little incinerators  Medical waste incinerator  Pet animal cremation incinerator  Incinerator makers

Incinerator is a incineration gear, direct fire squander from gasoline fuel or oi gas. As different circumscription, incinerator could be named many words as below: 

Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators  Incinerator gas: Gas incinerator, oil incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator manufacturer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.  All around the world, in most nations, people anti incinerator since the incinerator will create a large Dioxin in the smoke. “Dioxins” refers to a group of poisonous chemical compounds that share certain chemical structures and biological features. Smart ash price, smartash incinerator price, smokeless crematorium, sterilization by incineration, supplier waste incineration china, syc 30 inciner, syc hospital, Dioxins could be released into the environment through woods fires, backyard burning of trash, certain industrial activities, and residue from previous commercial burning of waste. Dioxins break down very slowly and previous releases of dioxins from the man-made and natural resources still exist in the surroundings. Anyhow, we must remind this, that is large scale incineration pant, generally more than 30 ton every day. This is a societal problem, to examine and suggest ways in various angles from the public, government, economic growth, environmental protection, technology advancement, etc. 

So, why we still use incinerator?  First, for the medical waste in the hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can ruin the virus, pollution control.  Secondly, for individual body, pet animal, in most nations and regions, we want to cremation them. This is the ceremony in the procedure for society growth, and ceremonies to commemorate the disappearance of life. 

As preceding two reason although not just above, we still use incinerators. 

the way you are able to find reasonable incinerator to your regional site?  Incinerator is not a cheap equipment, generally the little scale version 's price around $5, 000USD per unit and large scale version 's price more than $50, 000USD each unit. Thus, before purchase one unit incinerator, you need to make clear after items: A, burn out what? Incinerator is a incineration gear, function is flame squander. So what kind of waste that you would like to cure?  B, little or large? This according to the waste output daily or the waste volume per feed time, like animal size.  C, fuel? Incinerator use gas or oil , generally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some neighborhood site don't have gasoline distribution system.  Along with other tech items, such as power(220V, 380V), waste feed door kind, incinerator structure, etc..

Once you clarify these, it is possible to go to find a local or international producers, requesting prices, technical specifications and finally purchasing the right products. 

Wrote by Nicky

Items/Model YD-30 YD-50 YD-100 YD-150 Items/Model YD-200 YD-300 YD-500 YD-600 Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 360 900 1200 1500 Primary Chamber (Liters) 2000 2400 4000 5500 Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 200 200 500 500 Secondary Chamber (Liters) 500 1200 1500 1500 Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 200 300 300 500 Oil Tank(Liters) 300 500 500 500 Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 5 5 10 10 Chimney (M) 10 10 14 14 Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES Temperature Monitoring YES YES YES

Waste Incineration Equipment


Basic Info.

Export Markets:Global

Additional Info.

Trademark:CLOVER
Origin:Pr China
Production Capacity:1000 Sets Per Year

Product Description

2.

Medical Incineration (TS100 PLC)


Basic Info.

Model NO.:TS100 PLC
Pullution Sources:Solid Waste Processing
Processing Methods:Physics
Export Markets:Global

Additional Info.

Trademark:clover
Packing:Full Container
Standard:100 kg per hour
Origin:China
Production Capacity:1500units/Year

Product Description

Items/Model TS100(PLC)
Burn Rate 100 kg/hour
Feed Capacity 200 kg
Control Mode PLC
Combustion Chamber 1200L
Internal Dimensions 120x100x100cm
Secondary Chamber 600L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.7Kw
Oil Consumption (kg/hour) 14–28
Gas Consumption (m3/hour) 10–32.2
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 200L
Feed Door 80x60cm
Chimney 10Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800–1000 degree
2nd. Chamber Temperature 1000-1200 degree
Residency Time 2.0 Sec.
Gross Weight 6000kg
External Dimensions 260x150x180cm

Nanjing Clover Medical Technology Co., Ltd..

Medical Waste Incinerator Ts50 PLC


Basic Info.

Model NO.:china medical waste incinerators manufacturer
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste can utilize within this gear?  A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation substance, liquid gas and waste waste.  GB18484-2001. 

Q: Remedy capacity  A: Typical Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t indicate any waste material. The animal/pet combustion speed around 2/3 of average capacity. 

Clover incinerator utilize time daily to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding squander. Actual combustion time daily is about 16 hours. The life of incinerator between 5-10 year based on utilize. 

Ordinarily, we proposal small laboratory, small clinic use capability under 20 kgs per hour. If incinerator use in hospital, then please calculate the waste output capacity around 2kgs per people each day. If there are 200 sickbed in the hospital, that's imply you need one incinerator capability around 400kgs daily, change to capacity per hour is approximately 30-40 kgs per hour. According the performance time per day, waste material, funding, growth, etc, you can use capacity from 30-50 kgs each hour incinerator.  *The best way to calculate Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Assembly and Testing  A: We supply all files and incinerators easy to installation and functionality. Customer can send people visit our factory to find out operation and installation. Generally, We do not send engineer to local site if not ask. The dispatch cost is additional based on order. 

Q: Combustion Temperature  A: The first combustion chamber: 800-1000 centi level.  The second combustion chamber: 1000-1200 centi level.  PLC mode based on model and order. 

Q: Operation and maintenance costs  A: Operation cost based on fuel consumption rate and power/staff, etc. 

Annual approximately $500-$1000USD per year maintenance according version, use situation. 

One individual can service 02 device incinerators. China animal cremation, china incinerator supplier, cloverincinerator, backyard incinerator, hog incinerator, infectious waste pyrolysis machine china, ” The team should have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on performance user guider, also understand threat of medical waste to safeguard worker self with essential protection element. 

Q: The Residency period in secondary combustion chamber  A: 02 sec.

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Animal Waste Incinerator


Product Description

1.

3. Payment Term:  By sea: 50% deposit T/T (bank transfer) in advance, and 50% balance T/T before sending day.  By Train: 100 percent T/T in advance. 

4. Shipping Document & Packing: Generally, We provide (1)Bill of Lading (Way Bill), what's sample…(2)Commercial Invoice, (3)Packing List ONLY.  If any further documents/certification and tag print/words on packing documents or material which ask by importer or local customs, whatever happen in China or oversea, should notify seller in advance and charge as actual price. For instance, Fumigation Certification, embassy certification, BV/SGS…Inspection, certification of original (C/O), Form A, etc.. Heat value of medical waste, hog incinerator and cost, hog incinerators, residence incinerator, hospital incinerator feed, hospital incinerator images, hospital incinerator in China, Buyer must to notify seller in advance and pay these price. Seller save rights to postpone/cancel shipping and ask lost price cause this incident. If the importer local customs arrest/request penalty or other situation caused by buyer error, Clover Medical save all right to ask compensation/litigation. Thank you for your cooperation. 

5. The leading time is mostly 3-6 weeks, depending upon the products and quantity. 

7. Guarantee: One year for the gear. We provide spare parts for maintenance, free charge within the first year and the shipping cost is on the purchaser. 

8. Insurance: Bear all risks of loss of or damage to the goods from the time they have passed the boat 's rail at the named port of shipment. We proposition apply All Risks insurance under every contract. When purchaser pick goods at local site, must inspect carefully. If any damage occurred under insurance coverage, buyer must notify insurance business and Clover Medical Limited immediately. We will provide necessary assistance.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

cytotoxic waste


Our attention is for disposing mainly cytotoxic waste, particularly out of date or out of specs cytotoxic medicines. Numerous other wastes for which we would like to acquire rid of enhancement to the cytotoxic waste includes obsolete or out of specs pharmaceuticals (however not always narcotics), sharps (needles) and also so on.

It is additionally really critical for us to recognize whether the device is certified to manage cytotoxic waste in addition to also the characteristics in addition to disposal of treatment residue.

The quantity of disposal is about 100 kg per day as minimum. Larger skills approximately 500-600 kg/d are similarly of terrific interest to us. Hence, please send us your proposal for both aforementioned daily skills.


Municipal Waste Incinerator


Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Application Scope:  1.

Company License No.,: 320105000138343  Taxation Certificate No.: 320105571573734  Export Business Certificate No.: 3201571573734 

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Nanjing Clover Medical Technology Co., Ltd.. Is a top waste incinerator manufacturer in China. We’re local manufacturer and one of the largest exporter of China. Pyrolytic incinerator gear technical is main waste treatment all of the planet, for Medical Waste, what is a biological incinerator for pets, what is double chamber incierator, what is the average cost to get a medical incinerator, what is the cost of a pet cremation incinerator, Animal Incineration, Pet cremation and other Solid wste. The potential from 10kgs/Hr. To 500kgs/Hr. Up to 6ton per day. Currently , we supply different show for local customer requirements and layout upgraded incinerator with our top technology. The upgraded design feature of our assortment of incinerators make them one of the most cost effective in the world.