Medical Incinerator (TS20 PLC)


Basic Info.

Model NO.:TS20 PLC
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:CLOVER
Packing:Full Container
Standard:20 kg per hour
Origin:China
Production Capacity:1000 Sets Per Year

Product Description

TS model PLC incinerator is latest layout for waste treatment, include health care waste, animal cremation and other solid waste. This gear quality structural for types of site, small capacity incinerator,small home incinerator,small home incinerators,small hospital incinerator prices,small incinerator delers in ernakulam,such as hospital, environmental department, animal cremation agencies, etc.. CLOVER Incinerator provide updated models with double combustion chamber and smoke filter chamber using refractory lines, along with the combustion chamber temperature up to 1200 deg C.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg
Control Mode PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm
Chimney 3Meter 3Meter 5Meter 5Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 degree 800–1000 degree 800–1000 degree 800–1000 degree
2nd. Chamber Temperature 1000-1200 degree 1000-1200 degree 1000-1200 degree 1000-1200 degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm
 

Animal Waste Incineration, Pet Cremation Equipment


Product Description

Key Word:  Little incinerators  Medical waste incinerator  Pet animal cremation incinerator  Incinerator makers

Incinerator is a incineration gear, direct fire waste by gas fuel or oi gas. As different circumscription, incinerator can be named many words as under: 

Therapy ability: Small scale incinerator, big scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators  Incinerator gas: Gas incinerator, petroleum incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator manufacturer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.  All around the world, in most nations, people anti incinerator since the incinerator will produce a large Dioxin from the smoke. Dioxins can be released into the environment through forest fires, backyard burning of garbage, certain industrial activities, and residue from beyond business burning of waste. Dioxins break down very slowly and past releases of dioxins from both natural and man-made resources still exist from the environment. Anyhow, we must remind this, that is big scale incineration pant, normally more than 30 ton every day. This is a societal issue, to examine and suggest ways in different angles in the general public, government, economic development, environmental protection, technology advancement, etc. 

So, why people use incinerator?  First, for your medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can ruin the virus, pollution control.  Second, 100 kg incinerator, 100 kg/hr incinerator, 100 kg/hr incinerator for hospital waste, 100 kgs incinerator, 100 kgs/hr, 100 per hour, 100 ton incinerators uses natural gas, for body, pet creature, in many nations and regions, we desire to cremation them. This is the service in the procedure for society development, and ceremonies to commemorate the disappearance of life. 

As previously two reason although not only above, we nevertheless use incinerators. 

the way you can discover reasonable incinerator for your local website?  Incinerator isn’t a inexpensive equipment, normally the little scale model's price around $5, 000USD per unit and big scale version 's price more than $50, 000USD per unit. So, before purchase one unit incinerator, you have to make clear after items: A, burn out what? Incinerator is a incineration gear, function is flame waste. So what sort of waste you want to cure?  B, little or big? This based on the waste output every day or the waste volume per feed period, like creature dimensions.  C, fuel? Incinerator use oil or gas fuel, normally, gas fuel is less expensive than oil and the smoke cleaner than petroleum fuel model. However, some neighborhood website don't have gas distribution system.  And other technology products, like power(220V, 380V), waste feed doorway type, incinerator construction, etc. 

Once you describe these, it is possible to go to discover a local or global producers, requesting prices, technical specifications and ultimately purchasing the right products. 

Wrote by Nicky

Items/Model YD-30 YD-50 YD-100 YD-150 Items/Model YD-200 YD-300 YD-500 YD-600 Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 360 900 1200 1500 Primary Chamber (Liters) 2000 2400 4000 5500 Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 200 200 500 500 Secondary Chamber (Liters) 500 1200 1500 1500 Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 200 300 300 500 Oil Tank(Liters) 300 500 500 500 Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 5 5 10 10 Chimney (M) 10 10 14 14 Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES Temperature Monitoring YES YES YES

How to Design and Build an Medical Waste Incine


Product Description

Nanjing Clover Medical Technology Co., Ltd..

Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, extended life. *based on sequence * High temperature, long life of incinerator.  * Free or minimum installation onsite.  * High speed, from 10kgs to 500kgs per hour, up to 6ton daily.  * PLC Control Plane. *based on order  * New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock. 

Items Specification
Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Main Product List Double Combustion Chamber
Smoke Filter Chamber
PLC Mode Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Application Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation  Company License No.,: 320105000138343

Medical Waste Incinerator (YD-30C)


Basic Info.

Model NO.:YD-30C
Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

We, Clover Medical Limited, Located in China mainland.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Key Features:  * All model with Dual combustion chamber (Dual chamber).  * High temperature, long life of incinerator.  * Free or minimum installation onsite.  * High burn rate of up to 500kg per hour.  * Layout to medical waste and animal cremation.  * One year guarantee on incinerator.

Incinerator Video clip



Key Features:
— Full range incinerator with Economized Small Scale incinerator, 
Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, 
Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.
— Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.
— System solutions for medical waste environmental.
— High burn rate, from 5kgs to 1000kgs per hour.
— New Design for pet animal cremation business.
— HICLOVER, trusted partner with years of experience.



 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.



small capacity incinerators


Capacité destructive de 55 Kg/h jour de déchets hospitaliers  avec un p?.c. i jusqu’à 3.200 Kcal/Kg

1)Type de déchet

hospitalier

2)Pouvoir calorifique inférieur                                                                        3.200 kcal/kg

3)Humidité                                                                                                          20%

4)Teneur  en cendres et/ou inertes                                                                       8%

5)Capacité destructive nominale                                                                         55 kg/h

6)Volume chambre de combustion                                                                     1,65 m3

7)Volume chambre postcombustion                                                                   2.1 m3

8)Temps  transit des fumées en post combustion /sec.                                       <2

9)Température minimale  en postcombustion                                                     1.100° C

10)Teneur d’oxygène libre en postcombustion                                                     6%

11)Attribution refuse confectionné en sachets                                                     HDPE

12)Dispositif de chargement?: hydraulique?; capacité de charge                           0.5 m3

 

13)Combustible prévu                                                                                           Gasoil

14)Br?leur en chambre de combustion                                                                  nbr?: 1

15)Br?leur en chambre de postcombustion                                                           nbr?: 2

 

CONSTITTUTION DE L’APPAREIL.

1.CHARGEMENT

Système de chargement hydraulique afin de pouvoir charger le four en toute sécurité même durant son  fonctionnement et

aussi assurer la puissance destructive globale de 450 kg/j?

Le système comprend?:

1-1Trémie de chargement de forme parallélépipédique de 0,5 m3 de volume, réalisée en t?le d’acier, bridés sur la paroi

frontale de la chambre de combustion et munie d’un couvercle à charnières  actionné par vérin hydraulique?.

Dimensions?:

oLongueur 1200 mm

oHauteur 700 mm

oLargeur  600

1-2Un poussoir hydraulique  assurera le chargement de la chambre de combustion

1-3 Une  porte de chargement  de la chambre de combustion constituée  d’une  guillotine  à vérin hydraulique  revêtue

de réfractaire

1-4Un central  hydraulique pour piloter tous les vérins de commande, comprenant?: réservoir, pompe, électrovannes et

tuyauteries

 

2.CHAMBRE DE COMBUSTION PRIMAIRE

 

2-1- Le bati est une  structure métallique cylindrique revêtue intérieurement  d’une couche d’isolant et d’une

couche de réfractaire.

2-2-Volume intérieur?: 1,65 m3

2-3-Aménagement

?portillon de décharge  des cendres?:  frontal?; monté sur double charnière et revêtu de réfractaire avec hublot

d’inspection

?La connexion à la chambre de chargement est revêtue de réfractaire

?La connexion  de la   chambre de combustion et de la chambre de post combustion est revêtue de réfractaire

?Installation des bruleurs

?Installation  du système  de distribution de l’air comburant

?Installation des  sondes  de mesure de la température

?Le bac de récolte des cendres  est en acier au carbone sur roulettes, équipé de racloir métallique permettant

l’évacuation manuelle des cendres

  1. BRULEUR DE LA CHAMBRE DE COMBUSQTION

Un bruleur de type à une flamme à l’air soufflé, alimenté par gasoil, équipé des dispositifs de sécurité  Puissance

thermique installée 165 KW.

  1. AIR COMBURANT

Le système de distribution et dosage de l’air primaire en chambre de combustion comprend?:

?Ventilateur centrifuge

?Canalisations de distribution air

?Systéme de distribution d’air à 2 canaux

?Soupape de régulation de l’air motorisé selon les phases de cycle de fonctionnement et de la température