N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set


N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set

N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set

Dimension(L*W*H): 1037*855*1780

Power Supply 15.3kw mono phase

Net Weight: approx.: 1500kg

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-10


100 Kg/Hr Incinerator for Hospital Waste


Basic Info.

Model NO.:small medical waste incinerator
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. 

Nanjing Clover Medical Technology Co., Ltd..

The factory workshop local in liuhe Economic Development Zone, suburb of Nanjing and business office local in downtown region. Currently, incinerator line products market cover former Soviet Union region, Africa countries, Asia countries and Middle East region.  From year 2010, we negotiated with upgraded technology from Europe and America producers and establish alliance relationship in the land of China market. Little incinerators, waste incinerator, creature incinerators available, clover incinerator restricted, incinerator 500kg per, incinerator china manufacturer, Regrettably, competition in other countries market, country discrimination and anxieties of intellectual property rights cause failure finally. Presentlywe investment more attempt, funding and technology advancement in our own brand, we’re to be one of the most significant incineration equipment on earth. We have trading division company for expert export business service.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Family Pet Crematory with Movable system & & & & Auto. Door & & Independent Placement



Incinerator Model A1500, Intro

This design is big-scale pet cremation tools for huge pets.

Construction is dual/double combustion chamber with 03 units oil/gas burner, 
batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500). 
Primary & Secondary combustion chambers and included mix-combustion chamber, 
smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load on 
the bottom of chamber. Incinerator panel control suit for local operation.

Model

A1500

Burning Rate

Average 50 kgs/hour

Feed Capability

Ordinary 150 kgs

Key Combustion Chamber

1500 Liters

Extra Burning Chamber

500 Litres

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Setting

Hand-operated

Voltage

220V/380V

Gas Kind

Diesel Oil/ All-natural Gas/LPG

Heater

Italy Original

Oil Consumption (Diesel Oil)

Normal 34 kg/hour

Gas Consumption (Gas)

Common 41 m3n/hour

Inner Measurements

150 x 100 x 96cm (key chamber)

Outdoors Measurements

240 x 170 x 380cm (without chimney)

Temperature Monitor

Yes

Oil Container Capability( if oil gas)

300 Litres

Door Opening

59 x 81cm

Smokeshaft Length

10.0 Meters

Smokeshaft Type

Stainless-steel

Tools Gross Weight

7500 kgs

Operation Technical Specifications

Main Chamber Temperature

800 ℃–– – – -1000 ℃

Second Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Efficiency

> 98%

Waste Lower Calorific Power

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.



animal incinerator for sale


The incinerator shall be provided with a range of interconnecting ductwork between the thermal reactor outlet

and the inlet of the chimney. This ductwork shall consist of refractory lined tubes and high temperature resistant

tubes made from rolled sheet steel of minimum 3mm thickness, welded along the length.

 

  1. The standard chimney shall be made of carbon steel plates of minimum 3mm thickness.

Cooling air inlet gap shall be provided at the end of the refractory lined tube on the standard chimney.

 

  1. The individual chimney sections shall have flanges on both sides.

 

  1. All sections shall be primed and sprayed with zinc dust enamel paint.

 

  1. Support wires shall be provided on chimney stacks.

 

  1. The following shall be located within ductwork run:-

 

  1. Mounting tubes for optical smoke density instrumentation.

 

  1. Flexible expansion compensator.

 

  1. A connection for a chrome/alum. Thermocouple, which is an integral part of the flue gas temperature

indictor/two stage alarm system.

 

2.5  ACCESS DOORS

 

  1. These shall be hinged from the front plate of the primary combustion chamber and shall comprise

 

1-    A full width access/de-ashing door normally retained in the closed position by two handwheel clamps.

 

2-    A smaller waste charging door hinged from and located in the main door. This door shall have a minimum of 500

  1. x 500 mm. aperture and be normally retained in the closed position by means of quick release latch.

 

  1. A viewing port, so constructed that the observation/protective glass is capable of being cleaned whilst the

incinerator is in operation, and located in the waste charging door, to allow the operator to safely observe the

progress of combustion.

 

  1. Each door shall be fabricated from mild steel and be internally lined to the same standards as the combustion

chambers.

 

2.6  BURNERS AND BURNER CONTROLS

 

  1. A single burner, suitable for operation on fuel oil shall be mounted on each combustion chamber.


Specification of Setup and Comissioning of Waste Inci


Basic Info.

Model NO.:small scale incineratorssmall scale incinerators
Export Markets:Global

Product Description

Incinerator is a incineration equipment, direct fire waste by gas fuel or oi gas. As distinct circumscription, incinerator can be named many words as under: 

Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators  Incinerator gas: Gas incinerator, petroleum incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator maker, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer.  All around the planet, in most nations, people anti incinerator since the incinerator will produce a sizable Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical cremation equipment for medical waste makers, cremator 50 kg / h, crematorium equipment, crematory maker, dead animal incineration, dead creature incinerator, structures and biological features. Dioxins can be released to the environment through woods fires, backyard burning of garbage, certain industrial activities, and residue from previous business burning of waste. Dioxins break down very slowly and previous releases of dioxins from both natural and man-made sources still exist in the surroundings. Anyhow, we have to remind this, that is large scale incineration pant, generally more than 30 ton per day. This is a social issue, to examine and indicate ways in various angles in the public, government, economic development, environmental protection, technology development, etc. 

So, why we still use incinerator?  To begin with, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can ruin the virus, pollution control.  Second, for individual body, pet creature, in most nations and regions, we desire to cremation them.

As previously two reason although not just above, we nevertheless use incinerators. 

the way you are able to find reasonable incinerator to your regional site?  Incinerator is not a cheap equipment, generally the little scale model's price around $5, 000USD per unit and large scale model's price more than $50, 000USD each unit. Thus, before purchase one unit incinerator, you have to make clear following things: A, burn what? Incinerator is a incineration equipment, function is flame waste. So what kind of waste that you would like to treatment?  B, little or large? This based on the waste output every day or the waste quantity per feed period, like creature size.  Incinerator use gas or oil fuel, generally, gas fuel is less expensive than oil and also the smoke cleaner than petroleum fuel model. However, some neighborhood site don't have gas supply system.  And other tech products, such as electricity (220V, 380V), waste feed door kind, incinerator structure, etc..

After you clarify these, it is possible to go to find a local or international producers, asking prices, technical specifications and ultimately buying the ideal products.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

LOCAL STRONG WASTE INCINERATORS


a certain type to use at a crematorium. Something which allows especially for ashes collection etc.cremation alternative to the deceased’s family members. Is this thing perfect, are ashes easily accumulated and so on a cremator, for pet facility, can you present and also all detail of sales, tax obligation, environtment.-Plastic. 500Kg/hr and to be used optimal 6 times, is this means it will give just 3 tons every day? Keeping in mind that job files requires 10 tons/day
GREAT DEAL.
Fat-.
2.0

Medical incinerator using a 10 kg/hour (15 lbs/hour) capacity shall be constructed on the website, complete with Heaps, controller board in addition to all apparatus, abiding by 01015 exactly the same degree. 5.16.2.
– Rags & & oiled.
Household waste-.
Municipal incinerators using a 10-metric ton/24-hour capability, full with Heaps, controller board along with all accessories, complying with 01015 par. 5.16.1.
– Oils.
Plastic container-.
Filter, tires, belts.
– Chemicals, paint.
MUNICIPAL STRONG WASTE BURNERS

Local waste incinerator amounts and capacities will be created for 24-hour 7-day-a-week constant operation.

Incinerators shall be capable of processing both damp and also dry material as well as working on either diesel fuel, JP-8 gasoline,

or waste oil; visit Plumbing for gasoline storage system requirements. The complying with will be supplied as a minimum:

Strengthened concrete placing foundations, feed or charging hoppers (or loaders), main combustion chambers

with ash cleanout doors, secondary combustion chambers with ash cleanout doors, cyclone air filters (or separators),

and also induced atmosphere exhaust heaps (or chimneys).

The charging system will include, as a minimum, a receptacle for high feeding in addition to mechanically operated hydraulic

charging pliers or augur. To prevent warpage or extreme thermal expansion, a battery charger cooling system making use of

air or water is going to be provided.

Primary combustion chamber will be either the rotary- or mended fixed-hearth (or kiln) kind incinerator. Burner

and also combustion air controls shall be fully automatic for example, as a minimum, digital ignition in addition to all of

required interlocks along with security tools to offer secure operation. The room in addition to burner is going to be created to

keep a minimum burning temperature of at the minimum 700 into 870 C (1300 to 1600 F), however will not to go beyond 980

C (1800 F). The ash-removal system will incorporate the automatic constant elimination of the ash to an ashquench

pit in which warmed by water in addition to gotten rid of by conveyor. Burner in addition to combustion air controls shall be totally automatic

comprising of, as a minimum, electronic ignition along with all needed interlocks and safety and safety gadgets to supply safe

functioning. The ash-removal system shall include, as

a minimum, the straight guidebook removal into an entirely sterile

Cyclone air filters will likely be provided to eliminate the larger particulates. Cyclone air separators may be provided with

driven followers to enhance the speed of the gases inside the cyclone to enhance the collection effectiveness for smaller sized

bits.

5.16.2 MEDICAL WASTE INCINERATORS

Medical waste burners will be especially designed by the provider to eliminate medical wastes. All apparatus shall be made for 8 hrs

every day of continuous procedure in addition to be rated in quantity per hr (i.e. kg/hr or lbs/hr).

Burner packing or charging of medical waste will be batched-fed by hand.

Primary burning chamber shall function as static fixed-hearth (or kiln), multiple-chamber, retort form or larger

capability rotary-hearth (or kiln) kind. Heater in addition to burning air controls will be completely automatic for example, as a

minimum, digital ignition and all essential interlocks in addition to security tools to give safe process. The

room in addition to burner is going to be designed to keep a minimal burning temperature of at the minimum 760 into 870 C

(1400 to 1600 F). The ash-removal system shall incorporate the automatic continual removal of this ash into an ashquench

pit in which cooled down by water and removed by conveyor.

Second burning chamber is going to be a solid-walled and also -floored, flat, refractory-lined cyndrical tube kind

incinerator designed to oxidize (or shed) the organic vapors in addition to gases. Heater and burning air controls will be

completely automatic containing of, as a minimum, digital ignition in addition to all needed interlocks along with security and protection tools to

offer risk-free operation. The room in addition to burner is going to be created to maintain a minimum combustion temperature level

of a minimum of 930 to 1200 C (1700 to 2200 F) using a minimum gas home (or dwell) period of 2.0 secs. The ashremoval

system shall include, as a minimum, the direct manual removal into an entirely dry set receptacle.

Cyclone air filters will be awarded to remove the larger particulates. Cyclone air separators may be provided with

driven followers to elevate the rate of the gases inside the cyclone to improve the collection efficiency for smaller

particles. Stacks shall be the forced-air type and

completely independent and also unattached to nearby structures. As a minimum, heap peaks will lessen

downwash of stack discharges because of wind resistant effects from close-by frameworks and be determined in accordance

using DoD 4715.05-G, Overseas Environmental Standard Assistance File. Heaps shall be provided using

corrosion-resistant steel climate caps. ”

Heap dimension will be in accordance with the manufacturer’s recommendations. Stacks shall be the forced-air kind and also

completely independent and also unattached to nearby structures. As a minimum, pile heights will lessen

downwash of stack discharges because of wind resistant impacts from close-by frameworks and be determined in accordance

with DoD 4715.05-G, Overseas Environmental Standard Assistance File. Heaps shall be provided with

corrosion-resistant steel climate caps.”


Oil Fired Incinerator


Basic Info.

Export Markets:Global

Additional Info.

Trademark:CLOVER
Packing:ISO Container
Origin:Nanjing City China
Production Capacity:1000 Sets Per Year

Product Description

Q: What’s kind of waste may use within this gear?  A: This gear for pet creature, medical waste, Municipal waste, reside waste. Prohibit any volatile and radiation substance, liquid waste and gas waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Remedy capacity  A: Clover incinerator use time daily to 24 hours. Between every feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding squander. Actual combustion time per day is around 16 hours. The life of incinerator between 5-10 year according to use. 

Ordinarily, we proposition customer buy crematory according to animal size.  For small creature, cats, birds suit for small scale crematory (Model YD-15C/20C/30C).  For additional large animals, suit for model A1200, A1500, A2400, A4000. 

Q: Assembly and Testing  A: We supply all documents and incinerators easy to setup and functionality. Client can send people visit our factory to learn operation and installation. Normally, waste scale cost, waste to power sprinklers, incinerator capacity of 40 kg/hr, wat is the ability of burner to the incinerator of 100kg/hr, water dusti filters, We do not send engineer to local site if not ask. The dispatch cost is extra according to order. 

Q: Combustion Temperature  A: The first combustion chamber: 800-1000 centi level.  The second combustion chamber: 1000-1200 centi level.  PLC mode according to model and order. 

Q: Operation and maintenance costs  A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual approximately $500-$1000USD annually maintenance according model, use situation. 

One individual can service 02 unit incinerators. The team should have fundamental electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to operation consumer guider, and know risk of waste to safeguard worker self with mandatory security element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm