Mobile Containerized Waste Incinerators HICLOVER CA-200


Mobile Containerized Waste Incinerators pets or human cremation emergency use


Layout


CA-200

Picture

Burning Rate

Typical 100 kgs/hour

Main Combustion Chamber

2000 Liters

Second Burning Chimney

Yes

Feed Setting

Manual

Voltage

220V

Power

3.0 Kw

Gas Kind

Diesel Oil

Burner

Italy Original

Oil Usage (Diesel Oil)

Typical 53 kg/hour

Interior Measurements

200 x 100 x 100cm (main chamber)

External Dimensions

290 x 200 x 170cm (key space )

Temperature Level Screen

Yes

Oil Tank Ability( if oil gas)

500 Liters

Door Opening

90 x 90cm

Smokeshaft Size

5.0 Meters

Chimney Kind

Stainless Steel

Tools Gross Weight

9000 kgs( with container)

Operation Technical Specifications

Paimary Chamber Temperature

800 ℃–– 1000 ℃

Additional Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Effectiveness

> 98 percent

Waste Lower Calorific Power

3000Kcal


HICLOVER – Medical Environmental 

2020-06-27


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 


Another Question: disposing of waste


Just one Ebola patient treated at a U.S. hospital will generate eight 55-gallon barrels of medical waste every day.

Protective gloves, gowns, masks and booties are donned and doffed by all who approach the patient’s bedside and subsequently lost. Disposable medical tools, packaging, bed linens, cups, plates, tissues, towels, pillowcases and whatever which is utilized to clean up after the individual must be thrown away.

Even curtains, privacy beds and screens finally must be treated as contaminated medical waste and disposed of.

Dealing with this assortment of pathogen-filled debris without tripping new infections is an authorized and logistical challenge for each U.S. hospital currently preparing for a possible trip by the virus.

In California and other states, it’s an even worse waste-management nightmare.

While the U.S. Centers for Disease Control and Prevention recommends autoclaving (a kind of sterilizing) or incinerating the waste as a surefire way of destroying the germs, burning waste is effectively banned in California, also prohibited in several other states.

“Storage, transportation and disposal of this waste will be a significant issue,” California Hospital Association President C. Duane Dauner warned Sen. Barbara Boxer, D-Calif., in a letter a week.

Even some countries that generally allow incineration are throwing up barriers to Ebola waste.

In Missouri, the state attorney general has sought to bar Ebola-contaminated debris by a St. Louis incinerator run by Stericycle Inc., the country’s largest medical waste disposal company.

Due to restrictions on burning, California hospital agents say their only option seems to be trucking the waste over public highways and incinerating it in another country — a prospect which makes some environmental advocates uneasy.

Rules for transportation

Under national transportation guidelines, the substance would be designated a Class A infectious substance, or one that is capable of causing death or permanent disability, and might require special approval from the Department of Transportation, hospital agents state.

“We fully expect that it is coming our way,” Bayer said of this virus. “Not to create any sort of scare, but just handed the makeup of the population and the hub that we are. It’s very possible” It can’t survive a 1,500-degree scorching in a incinerator, or the prolonged, pressurized steam of an autoclave. “It’s killed by bleach, by autoclaving, by an assortment of chemicals.”

But, CDC guidelines note that”chemical inactivation” has yet to be standardized and could activate worker safety regulations.

Getting prepared

California health officials lately tried to reassure residents that the state’s private and public hospitals were up to the job and were actively training for the possible coming of Ebola.

“Ebola does not pose a significant public health risk to California communities at the current time,” explained Dr. Gil Chavez, an epidemiologist and deputy director at the California Department of Public Health. “Let me tell you why: Current scientific evidence specifies that individuals can’t access Ebola through the atmosphere, food or water. … The Ebola virus does not survive over a few hours on impervious surfaces”

It was uncertain if California officials saw the waste issue as a possible issue.

Although one third of the state’s private hospitals and”a few” of its public hospitals reported to Boxer’s office that there could be problems complying with the CDC’s incineration recommendation, along with many others, a state public health official told reporters he was not aware of any conflicts.

“Here’s what we’ve heard from the CDC: It’s OK,” Perrott explained. “But then we’ve heard from some sources, that perhaps we need to fix it somehow and then flush it down the toilet or you need to consult local authorities. It seems perhaps a bit gross, but there’s a real question about what to do with that waste.”

Dr. Thomas Ksiazek, a professor of microbiology and immunology at this University of Texas Medical Branch, has said he believes there has been a good deal of overreaction regarding Ebola medical waste.

“There are other methods to manage the waste; autoclaving would be chief among them,” Ksiazek mentioned. “The issue is, most physicians don’t use it for many disposable items. They are quite pleased to bag them up and send them into some normal medical disposal company.”

But Allen Hershkowitz, a senior scientist at the Natural Resources Defense Council, said incineration is straightforward and powerful, and must be available to hospitals to help dispose of this mountain of waste.

Hershkowitz said claims began to crack down on medical waste incineration years ago because substances which didn’t need to get burned were sent to combustors and so were emitting dangerous pollutants.

In this case of Ebola medical waste, he said California should reconsider its limitations.

“There is no pollutant that’s going to come out of a waste incinerator that’s more dangerous than the Ebola virus,” Hershkowitz said. “When you’re dealing with biological and sociological dangers, sometimes the safest thing to do would be combustion.”

by: http://www.sfgate.com/news/article/Another-challenge-disposing-of-waste-5909413.php

But Allen Hershkowitz, a senior scientist at the Natural Resources Defense Council, said incineration is simple and effective, and should be available to hospitals to help dispose of the mountain of waste.

Hershkowitz said states began to crack down on medical waste incineration years ago because materials that didn’t need to be burned were being sent to combustors and were emitting dangerous pollutants.

In this case of Ebola medical waste, he said California should reconsider its restrictions.

“There’s no pollutant that’s going to come out of a waste incinerator that’s more dangerous than the Ebola virus,” Hershkowitz said. “When you’re dealing with pathogenic and biological hazards, sometimes the safest thing to do is combustion.”

by: http://www.sfgate.com/news/article/Another-challenge-disposing-of-waste-5909413.php


Medical Waste Burner for Coronavirus Condition


Coronavirus Disease 2019 (COVID-19) pandemic continues all over the world, clinics,hospitals,goverment may need to consider on-site disposal for the infectious 

medical waste. The medical waste incinerators that has been effectively used to dispose of hazardous waste during 

viral outbreaks like Ebola. HICLOVER.COM reaches temperatures of up to 1200oC and is able to destroy health care waste 

for laboratories, small clinics, and hospitals treating patients of the Novel Coronavirus (COVID-19) such as linens, sharps, gauze, gowns, etc.

— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.

— Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.
— System solutions for medical waste environmental.
— High burn rate, from 5kgs to 1000kgs per hour.
— New Design for pet animal cremation business.
— HICLOVER, trusted partner with years of experience.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. 
We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc. 

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 5300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 300
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chmaber Temperature 1000-1200 1000-1200 1000-1200 1000-1200
Our range of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums.
The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection. 
System solutions for medical waste environmental, including waste incineration, smoke emission treatment, high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc. 
The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world. 
The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no incineration house build construction, movable by truck and ultraviolet lamp sterilization inside.
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.
Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chmaber Temperature 1000-1200 1000-1200 1000-1200 1000-1200
We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.
Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 2100 kgs 2100 kgs 2300 kgs 2500 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 


block diagram of burner



Our variety of burners provide for tiny to large range animal cremation related companies, such as poultry ranches, cattle ranches, sheep ranches, pig farms, stables, kennels, testing lab, catteries, pet dog crematoriums.

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.solid waste incinerator,incinerators for sale,industrial incinerator,incinerater

System solutions for clinical waste environmental, consisting of waste incineration, smoke discharge therapy, high-temperature sanitation, ultraviolet sanitation light, waste shredder, needle destroyer, medical waste package, sharp containers, and so on.



Medical Waste Incinerator Diesel and Gas Specification


Basic Info.

Model NO.:medical solid waste incinerator 100kg
Export Markets:Global

Product Description

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according to sequence * High temperature, long lifetime of incinerator.  * Free or minimal installation on site.  * High speed, from 10kgs to 500kgs per hour, up to 6ton daily.  *according to order  New Design for pet animal cremation enterprise.  * One year warranty on incinerator and components in stock. 

Program Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation  Company License No.,: 320105000138343

Items Specification
Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Main Product List Double Combustion Chamber
Smoke Filter Chamber
PLC Mode Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Plus Size Burning Rate : 150-200 kg/hr Strong Waste Devices Main as well as 2nd Combustion Chamber Burner



Items/Model

TS500( PLC)

Photo

Principle

Waste Incineration Therapy

Melt Rate

150-200 kg/hour

Control Setting

PLC( Programmable Reasoning Controller Heater)

Combustion Chamber

2700L

Inside Dimensions

190x120x120cm

Second Chamber

1300L

Smoke Filter Chamber

Yes

Feed Setting

Manual

Voltage

220V

Oil Intake (kg/hour)

Common 28

Gas Use (m3/hour)

***

Temperature Show

Digital Show

Temperature Level Safety And Security

Yes

Oil Tank

1400L

Feed Door

90x80cm

Chimney

10Meter

Smokeshaft Kind

Stainless Steel

1st.

Gross Weight

15000kg

Outdoors Dimensions

400x210x300cm( without chimney)

2020-03-21

400x210x300cm( without chimney)

The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The minimum combustion temperature of the primary chamber should not be less than 850°C;
The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.
The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.
The following conditions should be met in the secondary combustion chamber:
The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;
The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;
The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;
The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21



Model YD-150 for Casablanca Morocco”


Model YD-150
Burning Rate 150 kgs/hour
Feed Capacity 300 kgs
Paimary Combustion Chamber 1500 Liters
Secondary Combustion Chamber 500 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 1.03Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 17–36 kg/hour
Gas Consumption (Natural Gas) 11–36.7 m3/hour
Internal Dimensions 150 x 100 x 96cm (paimary chamber)
External Dimensions 240 x 170 x 380cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 300 Liters
Door Opening 59 x 81cm
Chimney Length 10.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 7000 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800℃–1000℃
Secondary Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Burning Efficiency >98%
Waste Lower Calorific Power 3000Kcal

 


small medical waste incinerator


i- burners:

use diesel , natural gas , liquefied petroleum gases according to standards burners should have main vent to be used

for protection.

2- materials:

-the chamber should be covered from inside with refractory brick with thickness 22 cm aluminum silicate insulation 11cm

thickness with the ability to change this layer .

– All surfaces made of carbon steel should be surface treated and covered with primary layer. That holds the working

condition and easy to clean it is recommended that materials are chosen according to standard codes.

Chimney exhaust gas filtration:

To meet the European standard 2000/76/EC

Chimney height should not be less than 12 meter and radius 8 cm.

 

– Treat the gas has a minimum temperature of 1100 ° C with a minimum residence time of two seconds the afterburner is

to;

– A secondary air injection is expected and provides perfect oxygen content;

– The burner ensures a minimum temperature of 1100 ° C continuous;

– The design of this burner is similar to combustion burners;

– The afterburner is equipped with access doors in order to ensure regular cleaning of dust;

– The afterburner is lined with high thermal insulation with a thickness of 150 mm

 

  1. Cabinet, control and regulation:

– The entire installation will conform to European standards (EU)

– The electrical power is 220V 50Hz single phase.

– Regulators of temperature with digital display:

? 1 to regulate the temperature of the combustion chamber

? 1 for controlling the temperature of the afterburner

? The manual controls are provided on each item.

  1. Should have preparation, Incineration, Scrubber steps to burn waste completely and waste gas should be non-

polluted

 

  1. Heavy duty steel, heat resistant coating, stainless steel lid, painted tubular steel frame, 2-blowers, axial

vane, suitable drum (S/S, thick) for the incinerator must be provided.

 

  1. Approx. 20 to 25 Kg per batch and the time required for 1 batch not more than 1 hour on average.