System Solutions for Medical Waste Environmental, consisting of Waste Incineration, Smoke Discharge Treatment, High-temperature Sterilization, Waste Crusher, Needle Destroyer, Medical Waste Plan and Containerized Mobile Incinerators.
System Solutions for Medical Waste Environmental, consisting of Waste Incineration, Smoke Discharge Treatment, High-temperature Sterilization, Waste Crusher, Needle Destroyer, Medical Waste Plan and Containerized Mobile Incinerators.
Technology Respond(FAQ)
Q: What is kind of waste can use within this gear? A: This gear for medical waste, pet animal, Municipal waste, reside waste. Prohibit any volatile and radiation substance, liquid waste and gas waste. GB18484-2001.
Q: Remedy capacity A: Typical Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour), not indicate any waste material. The animal/pet combustion rate around 2/3 of ordinary power.
Clover incinerator use time per day up to 24 hours. Between every feed/combustion time, there are approximately 0.5-1 hours cooling time plus time to get feeding squander. Medical waste, medical waste incinerator china, pet incineration gear, pet incinerator for sale, mobile incinerator manufacturers, waste incinerator manufacturers out of china, Actual combustion time daily is about 16 hours. The life of incinerator between 5-10 year according to use.
Generally, we proposition little lab, little clinic use capability under 20 kgs per hour. If incinerator use in hospital, please compute the waste output capacity around 2kgs per individuals per day. If there are 200 sickbed in the clinic, that's imply you need 1 incinerator capability around 400kgs per day, switch to power per hour is around 30-40 kgs per hour. According the operation time per day, waste material, funding, development, etc, you can use capacity from 30-50 kgs each hour incinerator. *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Meeting and Testing A: We supply all files and incinerators simple to installation and functionality. Customer can send individuals visit our factory to learn installation and operation. Generally, we don’t send engineer to local site if not request. The dispatch cost is additional according to order.
Q: Combustion Temperature A: The very first combustion chamber: 800-1000 centi degree. The second combustion chamber: 1000-1200 centi degree. PLC mode according to order and model.
Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD annually maintenance according model, use situation.
One person can service 02 device incinerators. The team should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know threat of medical waste to safeguard worker self with necessary protection element.
Q: The Residency time in combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
HICLOVER now supplies additional components including:
— — — — Burners (diesel oil, LPG or gas)
— — — — Facet for heaters
— — — — Fire ropes
— — Incinerator chamber maintenance items
— — — — Air Follower
Nanjing Clover Medical Technology Co., Ltd..
Key Features: * All models with Dual combustion chamber. * Stainless Steel chimney/stack, long life. *according to sequence * High fever, long life of incinerator. * Free or minimal installation on site. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. *according to order * New Design for pet animal cremation enterprise. * One year warranty on incinerator and parts in stock.
Items/Model | TS50(PLC) |
Picture | |
Burn Rate | 50 kg/hour |
Feed Capacity | 100kg |
Control Mode | PLC |
Combustion Chamber | 560L |
Internal Dimensions | 100x80x70cm |
Secondary Chamber | 280L |
Smoke Filter Chamber | Yes |
Feed Mode | Manual |
Voltage | 220V |
Power | 0.7Kw |
Oil Consumption (kg/hour) | 12.1–24 |
Gas Consumption (m3/hour) | 9.9–26.1 |
Temperature Monitor | Yes |
Temperature Protection | Yes |
Oil Tank | 100L |
Feed Door | 70x55cm |
Chimney | 5Meter |
Chimney Type | Stainless Steel |
1st. Chamber Temperature | 800degree–1000degree |
2nd. Chamber Temperature | 1000degree-1200degree |
Residency Time | 2.0 Sec. |
Gross Weight | 4500kg |
External Dimensions | 230x130x155cm |
Program Scope: 1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 3. Community & Sea Port & Station: Municipal Solid Waste, etc. 4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation
![]()
Items/Model
TS30( PLC)
Picture
![]()
![]()
Shed Price
Typical 30 kg/hour
Feed Capability
Regular 60kg per feeding
Control Mode
PLC( Programmable Logic Controller Burner)
Car Control and Screen
Burning Chamber
330L
Internal Dimensions
75x75x60cm
Second Chamber
180L
Smoke Filter Chamber
Yes
Feed Setting
Manual Feeding
Voltage
220V
Power
0.5 Kw
Oil Consumption (kg/hour)
Regular 13.3
Gas Consumption (N.G, m3n/Hour)
Typical 16
Gas Usage (L.P.G, m3n/Hour)
Average 11.7
Infection Monitor
Four Digital Screen
Temperature Level Defense
Yes
Oil Container
200L
Feed Door
55x50cm
Chimney
5Meter
Smokeshaft Kind
Stainless-steel
1st.
800 ℃–– -1000 ℃
moment. Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Gross Weight
3000kgs/4000kgs
Outside Measurements
175x120x140cm
Flue Gas Cleaning
System
? Wet Scrubber
? Electrostatic precipitation in combination ( Optional: Rate to be
quoted separately)
7 Chimney Height 10m (minimum)
? Total duration of the supervision of installation, testing and commissioning works shall not exceed 2 weeks.
2.11 Commissioning
Commissioning tests to be carried on site shall include but not limited to the following.
? Capacity test with respect to guaranteed particulars
? Emission test with respect to limits set in annex 1. Note that bidder shall provide its own test kit for
carrying out the emission tests.
? Flame safeguard. The operation of the flame safeguard system should be verified by causing flame and ignition
failures. Operation of the audible alarm (where applicable) and visible indicator should be verified. The shutdown
times should be verified.
? Testing of all shutdowns to the system.
? All interlocks provided should be tested for proper operation as specified by the unit manufacturer.
? Combustion controls. The combustion controls should be stable and operate
– For some applications requiring rotary kiln incinerators but narrow;
– For hospital; incinerators requiring fuel as LPG, diesel or heavy fuel oil: This market segment, my company have been
had group customers to supply the equipment for more 5 years.
– Especially, the incinerator – model series (No auxiliary fuel is required): Those products are feasible to sales
hundreds and thousand over the Vietnamese market in case of your products owned the optimal technical specifications
and reasonable price. Those products are beginning and suitable solution for combusting solid waste in Vietnamese
market which I have already market research and testing.
Presentlywe supply different collection for local client requirements and design updated incinerator with our top technology. The updated design characteristic of our range of incinerators make them one of the most cost effective on the planet. Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. * High temperature, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day. * PLC Control Plane for Intelligent functioning. * New Design for pet animal cremation business. * One year warranty on incinerator and components in stock. Incinerator is a incineration gear, direct fire squander by gas medical smokeless incinerators, medical technology fabrication italy, medical waiste furnce, medical wast burner china, medical waste 3000kcal/kg, fuel or oi fuel. As different circumscription, incinerator could be termed many words as under:
Treatment ability: Small scale incinerator, large scale incinerator and incineration pant.
Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators
Incinerator fuel: Gas incinerator, oil incinerator
Waste to Energy (WTE): WTE incinerator, non-WTE incinerator
Incinerator Manufacturer: China incinerator producer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.
Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)
Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Item | Specification |
Model | TS50 PLC |
Main Product List per 01 set | Primary Combustion Chamber |
Secondary Combustion Chamber | |
Smoke Filter Chamber | |
Incinerator PLC Control Case | |
Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) |
|
Italyoil/gas burner: 02 units | |
Oil Tank (if oil fuel): 100Liters |