Medical Waste Incinerator


Product Description

Waste Incinerator International Market Analytics  Date.

Keyword:  Little incinerators  Medical waste incinerator  Pet animal cremation incinerator  Incinerator makers

Incinerator is a incineration gear, direct fire waste by gas fuel or oi gas. As different circumscription, incinerator could be termed many words as under: 

Therapy capacity: Small scale incinerator, big scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators  Incinerator gas: Gas incinerator, petroleum incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator maker, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.  All over the world, in most countries, people anti incinerator since the incinerator will produce a sizable Dioxin from the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins could be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from past business burning of waste. Dioxins break down very slowly and past releases of dioxins from the natural and man-made sources still exist from the surroundings. Anyhow, we must remind that, this is big scale incineration pant, generally more than 30 ton every day. This is a social problem, to examine and suggest ways in various angles in the general public, government, economic growth, environmental protection, technology advancement, etc. 

So, why people still use incinerator?  First, for your medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can ruin the virus, pollution management.  Second, for human anatomy, pet animal, in several countries and areas, we desire to cremation them. This is the ceremony in the process of society growth, and ceremonies to commemorate the disappearance of existence. 

As previously two reason although not only above, we still use incinerators. 

How you can find reasonable incinerator for your regional website?  Incinerator isn’t a cheap equipment, generally the small scale version 's price around $5, 000USD per unit and big scale version 's price more than $50, 000USD each unit. So, before buy one unit incinerator, small incinerator for medical waste china, small incinerator medical waste maker, small incinerators medical, small all-natural gas trash incinerators, small scale incinerator china, you need to make clear following items:  A, burn what? Incinerator is a incineration gear, function is fire waste. So what kind of waste that you want to treatment?  B, small or big? This according to the waste output every day or the waste quantity per feed period, like animal dimensions.  C, fuel? Incinerator use gas or oil fuel, generally, gas fuel is less expensive than oil and the smoke cleaner than petroleum gas version. However, some neighborhood website don't have gas supply system.  And other technology items, like electricity (220V, 380V), waste feed doorway type, incinerator structure, etc..

Once you clarify these, it is possible to go to find a local or global producers, asking prices, technical specifications and finally purchasing the right products. 

Wrote by Nicky

Items/Model YD-30 YD-50 YD-100 YD-150 Items/Model YD-200 YD-300 YD-500 YD-600 Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 360 900 1200 1500 Primary Chamber (Liters) 2000 2400 4000 5500 Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 200 200 500 500 Secondary Chamber (Liters) 500 1200 1500 1500 Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 200 300 300 500 Oil Tank(Liters) 300 500 500 500 Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 5 5 10 10 Chimney (M) 10 10 14 14 Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES Temperature Monitoring YES YES YES

incinerators


  1. The publications listed below form a part of this specification to the extent referenced. The publications are

referenced in the text by basic designation only.

A1) Technical Specification:

Incinerators

All types of diesel fired incinerators suitable for HCW may be offered as long as they can

safely treat medical waste. The equipment should be compliant with all requirements for

installation in Kenya. All components for installation must be included.

 Technical evaluation will consider the entire system including the treatment plant. It will be

the responsibility of the Bidder to supply a full system, including all necessary secondary

systems and/or additional equipment.

The calorific value of the generated waste from the healthcare facilities differs from 5,000 kJ/kg

(e.g. pathological waste) up to 40,000 kJ/kg (filled sharp boxes) with an expected average

heating value of waste of 14,000 kJ/kg.

An approved plant must have four distinct sections that demonstrate three principles of

Turbulence, Residence Time and Temperature inbuilt in the plant design .The regulated sections

may include but not limited to:

 Overall plant layout

 Feed chamber/ charging

 Primary Combustion Chamber

 Secondary Combustion Chamber

 Particulate Scrubbers

 Acid Gas Scrubbers

 The stack/ chimney

For the main incineration process, a static, two chamber system is required with one main

combustion chamber and one flue gas afterburning chamber. The incinerator must be able to

meet the following parameters:

  1. Treatment capacity of: a) 50 kg waste per hour.
  2. Temperature: Main combustion chamber up to 850°C, and in the second chamber > =

1,100 °C

  1. Retention Time: 2 seconds in the second chamber

The furnace (including secondary combustion chambers etc.) dimensions must be large enough

to provide for an effective combination of gas residence time and temperature such that

combustion reactions may approach completion and result in low and stable CO and VOC

emissions.

In order to avoid the generation toxic gases, the incinerator must combine the gasification or

pyrolysis stage with a subsequent combustion stage with flue-gas treatment that provides for

operational emission levels to air within the associated emission ranges specified in the standards

5

for incinerators which are described in the ENVIRONMENTAL MANAGEMENT AND COORDINATION

(WASTE MANAGEMENT) REGULATIONS 2006 of the Republic of Kenya.

Where grates are used, it is preferred that the design incorporates sufficient cooling of the

grate such that it permits the variation of the primary air supply for the main purpose of

combustion control, rather than for the cooling of the grate itself. Documents to be

provided by the Bidder in response to this RFP.

 Complete information on how the equipment matches the Technical Specification.

Include an additional statement with a calculation and description of all cost related to the

normal running of the plant over a 12 month period.

 Full description of the system(s) being proposed.

 Lay out drawing with all main equipments, flue gas ductwork and main piping.

 Piping and Instrumentation Diagram.

 Operation manual in the English language.

 Material lists.

 Implementation plan and training concept.

 Installation and maintenance plan.

 Detailed list related to wear and spare part package for 2500 h operation (items which

will be included in the contract). The list should be detailed enough to allow PATH to

carry out a cost estimation.

Other information such as process description, brochures, etc. should be only added if

the information will be useful for the technical evaluation of the treatment process.

 

A2) Technical Specification:

Medical Waste Autoclave

 

Manual autoclave with vertical loading; gravity displacement type with possibility for Vacuum.

Capacity: Up to 12 kg/h

Chamber size: >150 liters

Material: Stainless steel

Temperature: 134 °C

Further information:

 Minimum autoclave chamber size shall be 150 liters and shall have a usable volume

(loading basket) of 100 liters.

 Shall work according to gravity air displacement principle.

 The vacuum system shall be of a thermal shock type.

6

 The pressure vessels should be pressure tight, the rising of the pressure (at a start pressure

of below 80 mbar) shall be lower than 1 mbar/min.

 With in-build electrical heating elements for steam generation (heating elements > 4000

Kw).

 Chamber and door shall be made from high quality stainless steel (e.g. AISI 3161).

 Chamber in vertical position, it shall allow an easy loading/unloading of the loading

basket.

 2 Baskets of >100 l for the loading and unloading of waste shall be included. The baskets

shall be designed for the usage of non-heat resistant waste bags, a system for the

collection and controlled release of free liquids and condensate from the waste shall be

incorporated.

 The temperature measured at the reference measurement point of the treatment chamber

shall not be lower than 105°C (TDes 0+4). The treatment time shall be ≥30 minutes at

105°C, ≥20 minutes with a temperature used of ≥121°C (TDes 0+4) and ≥10 minutes

with a treatment temperature of ≥ 134.

 The steering of the treatment process should be semi-automatically as well as manual.

 The Treatment Equipment shall be equipped with at least the following instruments:

o treatment chamber temperature indicating instrument

o treatment chamber pressure indicating instrument

 For the treatment of the outgoing air, a HEPA filter in combination with a condensation

system should be used.

 The filter shall be built in a way that a disinfection of the filter shall be possible in a builtin

condition.

 The filters must be heat resistant, steam resistant, hydrophobic and pressure resistant for

the pressure difference.

 Cooling down phase after treatment should be existent; the temperature of the waste

should be not higher than 80°C after finishing the cooling down process.

 The pressure vessel should be equipped with a heat insulation, the maximum outer

surface temperature should be < 50°C.

 The manufacturer must provide a declaration that the pressure vessel is manufactured in

accordance with relevant guidelines for pressure equipment.

Following accompanying documents should be supplied with the treatment system and

shall be available at the Site:

  1. Operation instructions (including process description).
  2. Loading and maintenance procedures.
  3. Short-form of operation and loading procedures.
  4. P&I diagram, circuit plan, technical data sheet, pressure vessel certificate.


medical incinerators


● Able to burn 25-30kg per hour

2 sec.
● Onboard or in-built fuel storage tank & ought to use no longer than 12L of expires el per hour to burn 25-30kg of waste
Key Features
● Low maintenance design
● Consist of 2 chambers to guarantee significant reduction in emission
1000×1670
Height Excl.
790
·         General wastes produced on a daily basis  include paper, plastic, natural materials, boxes, plastic containers, leaves, etc;

·         Total waste produced per day: 10-12 tonnes;

·         Hours of Operation: 10 hours a day;


pet incinerator for sale

1.    Capacity of destruction in weight: 60 Kg/h.
2.    It should be able to operate not less than 10 hours/day
3.    This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
4.    Design Specification : Types A, B, C, D, and E of medical waste
5.    “PYROLYTIC” combustion, by controlling the gasification of waste.
6.    The incinerator must avoid the release of black smoke and fine dust, during the loadings.
7.    It should be able to reduce the volume of wastes by 98%.
8.    It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.
9.    The incineration should be completely free from visible smoke as well as offensive odours.
10.    The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
?    The Temperatures of combustion: Minimum will be 850oC and max 1400oC
?    Post combustion: >1100oC.
11.    The Internal diameter of the Chimney: ? 400 and its height: 8 m
12.    The Volume of the combustion chamber: 1.200 L
13.    The Dimension of the door for loading in cm: 70×70.
14.    Burner operation should be Automatic On/Off
15.    Fuel : diesel
16.    The supplier must provide  necessary information for the best of  the installation
This incinerator with “PYROLYTIC” combustion must have:
17.    A combustion chamber of waste:
* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load
* A burner of lighting which the use is limited to the ignition of waste.
* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.

Medical incinerator rates


INCINERATOR WITH CONTROL UNIT

Has been Especially designed for use in:

– Hospitals

– Clinics

– Laboratories

– Disaster relief Operations

– Animal Cremation

– Is Utilized to eliminate medical waste with reliable, on site

Tech

 

An innovative system for medical Centers. 

remove hospital waste (such as infectious and pathological waste)

effectively, and with a minimum of expenses.  Present personnel can

be instructed on the use of this product.medical incinerator prices

 

The operator opens the key room door, places the waste

indoors and turns on the unit.  A timed cycle preset by the operator

starts and the waste is decreased to 5% ASH BY VOLUME.

 

– Incinerates around 8 cubic feet (0.22 cubic meters) per load, which can be

normally 330 ibs (150kg) per (8 hour) day.

 

– Designed by experts in portable systems.

– No on site building

– Minimum training for operators.

 

 

– Constructed for safe, easy operation with advanced controls.

– Double room combustion and high exhaust temperatures, if

needed, in excess of 1025◦C.

– Preset cycle time mechanically controls start up and shut down

– Thermostatic temperature controller guarantees efficient gas consumption.

 


Hospital Incinerator (TS50 PLC)


Product Description

  Nanjing Clover Medical Technology Co., Ltd.  is a major waste incinerator maker in China. We’re local  producer and one of the greatest exporter of China. Pyrolytic incinerator equipment technical is primary waste treatment each one of the world, for Medical Waste, Animal Incineration, Pet cremation and other good wste. The potential from 10kgs/Hr. to 500kgs/Hr. , up to 6ton per day. Presentlywe supply different show for local customer requirements and layout updated incinerator with our leading technology. The updated design characteristic of our assortment of incinerators make them one of the most cost effective on the planet. This equipment quality structural for kindschinese manufacturers of cremation equipment,chinese medical incinerator manufacturers,chinese pet cemetary,chinese suppliers for incinarator,practice incinerator manufacturers, of website, such as hospital, environmental department, animal cremation services, etc… CLOVER Incinerator supply updated models with dual combustion room and smoke filter chamber with refractory lines, along with the combustion room temperature up to 1200 deg C.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg
Control Mode PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm
Chimney 3Meter 3Meter 5Meter 5Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 degree 800–1000 degree 800–1000 degree 800–1000 degree
2nd. Chamber Temperature 1000-1200 degree 1000-1200 degree 1000-1200 degree 1000-1200 degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm
 

incinerators that can handle Bio-Medical waste red bag

incinerators that can handle Bio-Medical waste (red bag) from research laboratories with level 2 and 3, animal research, and hospitals.  There are also a small amount of Pharmaceutical waste to be destroyed.  I would like your recommendations on what incinerators would handle the these requirement based on the following monthly kilograms of material.

 

Site 1 – 4,650Kgs per month (I have recommend that I install two incinerators at this location since it is a medical research facility and the usage is very high)

 

Site 2 – 1000Kgs per month (this facility deals more with animal research but also has red bag waste from their research side, they currently have a large animal carouse incinerator)

 

Site 3 – 1000Kgs per month (this facility is a local hospital with bio-waste from treating patients)

30kgs medical waste heater Design TS30 PLC .



30kgs per hour(average) medical waste incinerator, design dual 
combustion chambers(primary chamber and secondary chamber), 
smoke filter chamber, PLC auto. control system, 0.33m3(330liters)
primary combustion chamber, italy oil or gas fuel burner. for small 
hospital medical waste treatment.
Buy waste incinerator, find hiclover

Items/Model

TS30 PLC

Idea

Waste Incineration

Burn Rate

Criterion 30kgs/hour

Gas Kind

Diesel Oil/Natural Gas

Control Setting

Programmable Thinking Controller( PLC) Panel

Key Combustion Chamber

0.33 m3

Inner Measurements( Primary)

750x750x600 mm

Secondary Burning Chamber

0.18 m3

Internal Dimensions( Secondary)

400 x 750 x 600 mm

Smoke Filter Chamber

Yes

Feed Establishing

Guidebook

Voltage

220V

Power

0.5 Kw

Oil Intake

10.2– – 20.0 kgs/hour

Gas Consumption

9.8– – 20.0 m3/hour

Temperature Display

Digital Program

Temperature Level Protection

PLC Control

Time Setting

PLC Control, 0-120 Minutes

Oil Container

100 Liters

Waste Feed Door

550x500mm

Smokeshaft

5.0 Meter

Smokeshaft Kind

Stainless-steel

Key Chamber Temperature Degree

800 ℃–– – – 1000 ℃

Additional Chamber Temperature Degree

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

3000kgs

External Measurements

1750x1200x1400 mm


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator
Medical Environmental 

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.