Medical Incineraotors chamber of post combustion


1.A chamber of post combustion of gases
A burner of combustion of gases,
A device of injection of air allowing a total re-combustion of gases,
A device of air inlet of cooling of waste gases,
A sheath of evacuation of the gases burnt,
Carcass in strong sheet steel with support of connection
Composition of the refractory;
Refractory concrete:
Thickness :>150mm
Nature: 65%% of Al203
Insulate in fibrous panels:
Thickness: >85mm
Nature: Calcium
Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, 
electromagnetic sluice gate of regulation and isolating valve.
A secondary injection of air to ensure perfect oxygen content.
2.A control box ensuring the complete cycle of combustion.
3.Fan:
Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of 
the automatic cycle.
4.Controls and regulations:
Control box watertight to dust, including:
A switch circuit breaker for each engine (ventilators and burners).
A timer with adjustable temporization for the regulation of each burner.
A regulator with digital watching for the temperature of combustion.
A regulator with digital watching for the temperature of post-combustion.
Electric box.
5.The de-ashing must be done in the bottom of the combustion chamber or the de-ashing should be automatic or manual batch de-ashing.
6.Process filtering system: scrubber to be mentioned as optional
7.Emission standards compliance: BS 3316 or equivalent standard
8.Capacity to treat plastic: not less than 40% by weight
9.CE manufacturing compliance: BS EN 746-2-1997


Medical Waste Burner for Coronavirus Condition COVID-19




HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production)
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production 
TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 days 20sets/2 weeks
TS100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 7 days 15sets/2 weeks
TS150 average 150kgs per hour Average 750 SickBed Diesel Oil 5 sets 7 days 15sets/2 weeks
YD10 average 10kgs per hour Average 50 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD20C average 20kgs per hour Average 100 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD50C average 50kgs per hour Average 250 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
YD30 Small average 30kgs per hour Average 150 SickBed Diesel Oil 2sets 5 days 20sets/2 weeks
YD50 average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 5 days 20sets/2 weeks
YD100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD150 average 150kgs per hour Average 750 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD300 average 300kgs per hour Average 1500 SickBed Diesel Oil     10sets/2 weeks
YD500 average 500kgs per hour Average 2500 SickBed Diesel Oil     5sets/2 weeks
CA 50 Mobile Containerized average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 15 days 10sets/2 weeks
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-02



small scale medical incinerator


The burners shall comply with the requirements of BS 799 or DIN Standards. Each shall be the packed type and

incorporate automatic stop/start programmed timer control, flame failure equipment and ignition failure equipment to

close off the fuel supply in the event of malfunction.

 

  1. Each burner shall be designed and mounted for ease of access and so that they may be fully maintained from

outside the combustion chamber. The burners shall be mounted so that waste cannot block the flame ports.

SL No   Description   Fill up the bidder

Lot-A Specification

1     Hydroclave for Medical waste Treatment Plant

 

General Requirements

  • The processor must be approved to sterilize & treat the following types of medical waste:

—   Liquids: Blood, body fluids etc.

—   Blood bags & tubing, gloves, Gowns, drapes, etc.

—   Contaminated packaging: bandage etc

—   Sharps & Sharp containers

—   Disposable instruments

—   Glass products

— Human and animal tissue (surgical and pathologic)- Based upon MWM regulations.

— Cultures, stocks and glassware

 

*  The processor must comply with a documented efficacy level of 6 log10 reduction in spore survival (99,9999%) of the

Bacillus Stearothermophilus

* The processor should reduce the volume of the waste by 60% to 80% through complete dehydration and sterilization of

the waste

* The processor must have ZERO harmful emission level and meet or exceed all standards required by the EU.

 

The whole waste treatment system should be offered as a complete unit consisting of following equipment and

ancillaries-

(A) The sterilization processing unit

(B) Steam Boiler

(C) Tub washer

(D) Heavy duty external shredder

(E) Conveyer belt — based on Manufacturer’s Recommendations

(F) Bin Lift/Tipper

(G) Spore tester

 

 

(A) Features and Specifications of the Sterilization Processor unit:

Technical specification of the processor.

*  Steam autoclave in combination with a heavy duty Fragmenting System inside the vessel/ chamber

*  The vessel must be of Double Chamber

* Capacity (kg/load): minimum 2001cg/batch/cycle

*  Volume of 140-190 liters of bulk per cycle

*  Average Cycle time: 60 minutes

*  Operating temperature : 121°C to 135°C

*  Operating pressure: 1.1 Bar to 2.4 Bar

* Sterilization time : approx. 30 minutes at 121°C/1.1 Bar or approx 15 minutes at 132°C/2.5 Bar to achieve 6log10

sterility

* Fragmentation inside the chamber: Heavy duty with maximum size of final product <20 cm.

*  Volume reduction of the waste after processing : by 60-80% through complete waste dehydration including liquid

content of the waste

*  All actions after loading for sterilization, fragmentation of product is to be occurred in the same chamber/vessel

*  Pre or Post-air evacuation should not be necessary or used

*  Exhaust air quality: Does not require any venting for odor control

* Operating System: Fully automated with manual over-ride. (On board PLC capable of generating written report with

cycle time, cumulated time at > 121°C

* The option should be there for Internet connectivity by phone, cable or

* Boiler: should not require pre-heated water

* Electrical requirements: 220Vac, 1ph or 400vac 3ph to suit customer needs

* Noise level at full operation: < 80 dB

Working Principle of the processor:

*  The processor should utilize steam technology in conjunction With a mechanical fragmentor (grinder) to sterilize

medical waste, thereby  making the  residual waste safe for disposal in landfills.

*  The sterilization vessel MUST be a double walled (jacketed) cylindrical vessel

* Pre-shredding of infectious waste must not be accepted, the fragmentation must occur safety inside the scaled vessel

continuously.

* The sterilization vessel/chamber must be fitted with a motor driven shaft to which a heavy duty grinder(fragmenting

arm)  is attached inside the vessel to produce all unrecognizable size of the waste product.

* The Fragmenting are must rotate to agitate waste continuously throughout the heating and sterilization cycle to

ensure that the fragmented q agitated wastes (including sharps and liquids) are exposed evenly to sterilization

temperature and pressure.

* Steam heat should be applied to the jacket only, while the agitated waste absorbs the heat from the jacket and makes

its own steam from its moisture content.

* Should not need for special autoclave bags — simple bag or box should be workable

* MUST not need for hi c-treatment of the waste.

* Liquids and gases MUST remain locked inside the vessel until sterilization is complete – nothing should be vacuumed

or pumped out in its infected state.

* Jacket steals heat to dehydrate the waste completely regardless of its original water content.

* All the hot condensate from the jacket is recycled, making the processor very economical to operate


Containerized Mobile Burner Medical Waste Burner Model CA50


HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50


Model

CA50

Picture

Waste Therapy

Medical Waste Incineration Therapy

Feed Capability

Regular 100 kgs per feeding

Burning Price

Typical 50 kgs per hr

Burning Time per Feed

Average 2 hr

Control Mode

PLC( Programmable Reasoning Controller Incinerator)

Voltage

220V

Power

1.0 Kw

Gas

Diesel oil

Heater

Italy Burner

Feed Setting

Handbook

Temperature Level Display

Digital Display

Fuel consumption (Oil)

Average 16.9 Kgs/Hour

Interior Dimensions

100x80x70cm (Primary Chamber)

External Dimensions

230 x 130 x 155cm (text)

Waste burning chamber

560Liters

Message Burning Chamber

280Liters

Oil Container Capability

200 Litres

Door Opening

70 x 50cm

Smokeshaft

5.0 M

Gross Weight

4500kgs

Chamber Material

Firebrick, Refractory Concrete

Max.

166,000 Kcal/Hr.

Procedure Technical Specs

Solid Chamber temperature

8000C -10000 C

Gas Chamber temperature

10000C -12000 C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning effectiveness

> 98 percent

Waste Lower Calorific Power

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 


dispose Medical waste IV

the incinerator can be used to dispose  Medical waste IV, used needles, used syringes, scalpels, used dressing material ,personal protective equipments like gown, gloves etc. amputated body parts, excreta from patients and other laboratory waste.incineration units that can handle a mix of medical and hazardous wastes. The medical wastes include (but are not limited to) materials contaminated with blood, bodily fluids, fecal matter, and human tissue/organs from surgery. The hazardous compounds include (but are not limited to): xylene, toluene, chloroform, methylene chloride, trichloroethylene, acetonitrile, formaldehyde wastes, chemotherapy wastes (e.g., Chlorambucil, Cytoxin, Daunomycin, etc.) radiology wastes (e.g., glutaraldehyde), and mercury-containing compounds.includes amputated body parts, body fluids including contaminated blood, blood products, excreta from patients, cultures of contagious viruses and other laboratory wastes e.t.c.
Medical might also include used needles, used syringes, used , expired or contaminated dressing materials like bandages, plasters and plastics, e.t.c. The Incinerators should also allow for disposal of other wastes generated in hospital environment.Technical Specifications for Portable Incinerators

The Chamber volume of approximately 0.37m3 and a
1     combustible load volume (volume of material) of
approximately 0.30 m3

2     Burner power of approximately 189,000kcal/hour
Maximum Combustion Temperature of up to 1250

Degree Celsius
Type of emitted Gas: Inert and nil environmental pollution effect
Electrical Power: 220V/50 or 60 Hertz

Fuel: Diesel

Electrical consumption of approximately: 0.35 kw/hr

Fuel consumption range: 7 – 11 ltrs/hr

Controls: Incinerator control including control panel, timer, display for monitoring combustion temperature, system error display, etc.
Packaging/Installation: Incinerator fully assembled and ready to be plugged in power source

Instruction manual: Package must be provided with instruction manual including detailed information to installation, operation, maintenance, interpretation of trouble shooting signals and contact telephones
numbers/emails of local or overseas manufacturer’s technicians that can be contacted for guidance on operation of the equipment, if necessary.

training guide/manual on a compact disc including a demonstration for installation, operation and
maintenance, as well as safety guidelines, etc.

Scope of Supply: Package must be provided including
all the required accessories for installation and must
include spare parts/consumables that are required for a
one year period at a combustion rate of up to 8 hours
daily

Warranty must be provided for a 5-years period
starting with the incinerator’s installation and
including the provision of accessories and
consumables

Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS


Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS
Medical Waste Incinerator, 100 to 120 Kg/hr
Application   For incineration, general and pathological
Capacity    100 C 120 kg/h burn rate
Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit
Operating time                Minimum 8 hours daily
Operating temperature     From 850 0C to 1200 0C, Automatic controlled
Residual Ash                    5 to 10%
Construction Constructed from heavy duty mild or aluminized  steel
Or equal and approved equivalent

Insulation material            Refractory material lining similar or equal to calcium 
Silicate and hot face combination of heavy duty brickwork
Internal Construction        Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material
Charging Door                   Suitable for manual loading of wastes and with smooth 
Dear seal equivalent of Ceramic seals with hinges.
Door Lock                          Automatic, Electric type
Ash removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamber
Gratings    Provided
Loading Manual loading of waste
Primary Burner                        Fully automatic, with fuel, temperature and speed  controls with ignition system  flame detector                                                         Air fan Complete with safety features, flame failure                                                                    Diesel fired fuel injector type                                               
Flange mounted
Blower   Provided.  3 phase for supplying excess combustion air through the distribution system with speed control system
Temperature Minimum exit 850 0C
Observation port To be provided with protective glass type
     3.3    Secondary chamber


Environmental Incinerator


Product Description

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm